Preferred Language
Articles
/
joe-975
Evaluation of the Accuracy of Digital Elevation Model Produced from Different Open Source Data
...Show More Authors

This study aims to estimate the accuracy of digital elevation models (DEM) which are created with exploitation of open source Google Earth data and comparing with the widely available DEM datasets, Shuttle Radar Topography Mission (SRTM), version 3, and Advanced Spaceborne Thermal Emission and Reflection Radiometer Global Digital Elevation Model (ASTER GDEM), version 2. The GPS technique is used in this study to produce digital elevation raster with a high level of accuracy, as reference raster, compared to the DEM datasets. Baghdad University, Al Jadriya campus, is selected as a study area. Besides, 151 reference points were created within the study area to evaluate the results based on the values of RMS.Furthermore, the Geographic Information System (GIS) was utilized to analyze, imagine and interpolate data in this study. The result of the statistical analysis revealed that RMSE of DEM related to the differences between the reference points and Google Earth, SRTM DEM and ASTER GDEM are 6.9, 5.5 and 4.8, respectively. What is more, a finding of this study shows convergence the level of accuracy for all open sources used in this study.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jan 01 2025
Journal Name
Route Educational And Social Science Journal
DREAMS SOUND DIFFERENT IN THE WOODS: JAMES LAPINE AND STEPHEN SONDHEIM’S DRAMATI
...Show More Authors

View Publication
Crossref
Publication Date
Sun Jun 06 2010
Journal Name
Baghdad Science Journal
The contrast and illumination technique for image capturing under different Tungsten illumination
...Show More Authors

The digital camera which contain light unit inside it is useful with low illumination but not for high. For different intensity; the quality of the image will not stay good but it will have dark or low intensity so we can not change the contrast and the intensity in order to increase the losses information in the bright and the dark regions. . In this search we study the regular illumination on the images using the tungsten light by changing the intensities. The result appears that the tungsten light gives nearly far intensity for the three color bands(RGB) and the illuminated band(L).the result depend on the statistical properties which represented by the voltage ,power and intensities and the effect of this parameter on the digital

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Iop Conference Series: Earth And Environmental Science
Velocity Patterns inside the Proposed Makhool Dam Reservoir with Different Operation Plans
...Show More Authors
Abstract<p>The Makhoul Dam project proposed to be established is considered one of the strategic projects in Iraq as it works to insurance large quantity of water spare in flood seasons, increase the storage capacity of the dams in Iraq, as well as increase food security. The Makhool Dam is located on Tigris River in Salah al-Din Governorate, and 8 km south of the meeting point of the Tigris River with the Lower Zab River. The lake area is about 256 km2. In this research, a mathematical model was prepared by using HEC-RAS Two Dimension Software to analyze the velocity patterns and water depths inside makhool dam reservoir at the highest operational water elevation, based on the designs prepared </p> ... Show More
View Publication
Scopus (7)
Crossref (3)
Scopus Crossref
Publication Date
Fri Sep 30 2022
Journal Name
Journal Of Economics And Administrative Sciences
A Comparative Study for Estimate Fractional Parameter of ARFIMA Model
...Show More Authors

      Long memory analysis is one of the most active areas in econometrics and time series where various methods have been introduced to identify and estimate the long memory parameter in partially integrated time series. One of the most common models used to represent time series that have a long memory is the ARFIMA (Auto Regressive Fractional Integration Moving Average Model) which diffs are a fractional number called the fractional parameter. To analyze and determine the ARFIMA model, the fractal parameter must be estimated. There are many methods for fractional parameter estimation. In this research, the estimation methods were divided into indirect methods, where the Hurst parameter is estimated fir

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Feb 01 2024
Journal Name
Computers In Biology And Medicine
Model based smooth super-twisting control of cancer chemotherapy treatment
...Show More Authors

Chemotherapy is one of the most efficient methods for treating cancer patients. Chemotherapy aims to eliminate cancer cells as thoroughly as possible. Delivering medications to patients’ bodies through various methods, either oral or intravenous is part of the chemotherapy process. Different cell-kill hypotheses take into account the interactions of the expansion of the tumor volume, external drugs, and the rate of their eradication. For the control of drug usage and tumor volume, a model based smooth super-twisting control (MBSSTC) is proposed in this paper. Firstly, three nonlinear cell-kill mathematical models are considered in this work, including the log-kill, Norton-Simon, and hypotheses subject to parametric uncertainties and exo

... Show More
View Publication
Scopus (16)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Sat Sep 05 2020
Journal Name
Al-kindy College Medical Journal
Evaluation Aseptic Loosening of Primary Hip Arthroplasty
...Show More Authors

Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesisMethods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and

... Show More
Preview PDF
Crossref
Publication Date
Thu Feb 23 2023
Journal Name
Chalcogenide Letters
Fabrication and evaluation of CuAlSe2/Si photodetector
...Show More Authors

In this work, we have examined the spectral response of (p-CuAlSe2/n-Si) detector, (CAS) thin films deposited by thermal evaporation at RT with a thickness (450) nm, and annealing temperature at (473K) for 2 h. Optical transmission measurements displayed reasonably slight transmission besides higher absorbance trendy the visible region, energy gaps were observed by annealing, were found to be direct, and decreased with the effect of annealing. The extreme responsivity value arises at wavelength 459 nm, with improvement value of specific detectivity and quantum efficiency the annealing films be situated originate as greatest suitable aimed at numerous device application.

View Publication
Scopus (1)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Dec 30 2012
Journal Name
Al-kindy College Medical Journal
Evaluation of Medication Errors in Hospitalized Patients
...Show More Authors

Objectives: Many medication errors occur in the hospital, and these can endanger patients. The purpose of this study was to evaluate the incidence of medication errors in hospitalized patients, and to categorize the most frequent types of errors, and to asses the possible measures that may prevent the occurrence of such errors.
Methods: A prospective, exploratory, and evaluative study, using direct observation method to detect medication errors in adult hospitalized patients in medical and surgical units in Baquba Teaching Hospital- Diyala-Iraq.. The files of 299 patients had been reviewed from July 2009 to September 2009, including medication orders and treatment sheets to detect existing errors. The detected errors were recorded and

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 28 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and Evaluation of Flurbiprofen Oral Film
...Show More Authors

Fast dissolving film can be defined as a dosage form, which when placed in the oral cavity. It will rapidly disintegrate and dissolves to release the medication for oral mucosal absorption or allow for the gastrointestinal absorption to be achieved when swallowed.

Flurbiprofen is non-steroidal anti-inflammatory agent with antipyretic and analgesic properties and can be used   in low doses 8.75 mg as analgesic and anti inflammatory agent in sore throat infection. This study aims to   formulate flurbiprofen as oral dissolving films,   to improve the effective relief of pain with severe sore throats with little or no adverse effect.

Nine formulas were prepared using solvent-casting method, and t

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Tue Nov 22 2016
Journal Name
Der Pharma Chemica
Evaluation of Commercial Antacid Tablets in Iraq
...Show More Authors

Antacids are commonly used drugs which are considered inert and free of pharmacological effect by many patients and physicians. They are weak bases that neutralize the gastric acid and relief pain. These weak bases dissociate to neutralize gastric acid and form neutral salts. The ultimate goal of antacid therapy is to reduce the concentration and a total load of acid in gastric juice to a pH 4 - 5. This in vitro study was promised to study the acid neutralizing capacity (ANC) of six commonly available antacids tablets in the Iraqi market by using back titration method. The highest ANC values were for Rennie (17.131± 0.083 and 16.926± 0.052 mEq) in two different hydrochloric acid (HCl) concentrations 1N and 0.5 N, respectively. The static

... Show More
Scopus (1)
Scopus