Performance Enhancement of an Air Cooled Air Conditioner with Evaporative Water Mist Pre-cooling
...Show More Authors

The present paper deals with experimental investigation of the performance of air cooled split air conditioner, with evaporative water mist pre cooling to increase the cooling capacity and reduce the consumption power under hot and dry climate. This investigation considers how the performance can be enhanced by using water mist to pre-cool ambient air entering the condensers by adiabatic cooling process which depends on the ambient air wet bulb temperature; as well the condensing temperature and condensing pressure will be decreased accordingly. So the cooling capacity would be increased and consumption power would be decreased, consequently the energy ratio, EER would be improved. The performance of air cooled air conditioner with water mist pre cooling;
ECAC was compared to the performance of air cooled air conditioner, ACAC which tested under the same ambient condition that is ranged from 25 oC to 52 oC. Test results show that ECAC operating at EER of 10.5 BTV/W. The ECAC had an EER of 47 % higher than that of ACAC under the same and most serve hot and dry condition of 52 oC and 10% relative humidity. 
 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Dental Hypotheses
Evaluation of the Impact of Ozonated Water on Water Sorption and Solubility of Heat Cure Acrylic Resin: An In Vitro Study
...Show More Authors

Introduction: This study aimed to evaluate the impact of ozonated water on water sorption and solubility of heat-cure acrylic resin. Methods: Thirty-three samples of heat-cured acrylic resin were manufactured and divided into three groups: control, immersion for 10 and 20 minutes in ozonated water. Water sorption and water solubility tests were carried out in line with ADA Standard No. 12 for denture-base acrylic resin. Data were analyzed using one-way ANOVA at a significance level of 5%. Results: There was a nonsignificant difference between the control and experimental groups regarding water sorption (P

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Case Studies In Construction Materials
CFRP strengthening efficiency on enhancement punching shear resistance of RC bubbled slabs with openings
...Show More Authors

View Publication
Crossref (10)
Crossref
Publication Date
Sat Sep 01 2007
Journal Name
Al-khwarizmi Engineering Journal
Parametric study of thermal behavior of thrust chamber cooling channels
...Show More Authors

A numerical investigation is adopted for two dimensional thermal analysis of rocket thrust chamber wall (RL10), employing finite difference model with iterative scheme (implemented under relaxation factor of 0.9 for convergence) to compute temperature distribution within thrust chamber  wall (which is composed of Nickel and Copper layers). The analysis is conducted for different boundary conditions: only convection boundary conditions then combined radiation, convection boundary conditions also for  different aspect ratio (AR) of cooling channel. The results show that Utilizing cooling channels of high aspect ratio leads to decrease in temperature variation across thrust chamber wall, while no effects on heat transferred to the

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Influences of Operating Variables on Hydrodynamic Performance of Plunging Water Jet Downflow Bubble Column
...Show More Authors

The hydrodynamics of a co-current down flow bubble column has been investigated with air – water system. A Perspex bubble column of 5cm in diameter and 1.5m height is used as a test contactor using nozzles of 7, 8 and 9 mm diameter for air-water distributing. The column is provided with three electro-resistivity needle probes for bubble detection.
Experimental work is carried out with air flow rates from 0.09 to 0.45 m3/hr and liquid flow rates from 0.65 to 1.1m3/hr in order to study the effects of superficial gas velocity, nozzle diameter and liquid flow rate on the characteristics of hydrodynamic interactions viz. gas hold up, bubble diameter and bubble velocity by using two technical methods, direct height measurements for air-wa

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 29 2015
Journal Name
Separation Science And Technology
An acidic injection well technique for enhancement of the removal of copper from contaminated soil by electrokinetic remediation process
...Show More Authors

Scopus (16)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Tue Aug 09 2022
Journal Name
Journal Of Research In Medical And Dental Science
Evaluation of the Antibacterial Efficacy of Electrolyzed Oxidizing Water as an Irrigant against Enterococcus faecalis (An In vitro Study)
...Show More Authors

Evaluation of the Antibacterial Efficacy of Electrolyzed Oxidizing Water as an Irrigant against Enterococcus faecalis (An In vitro Study), Noor A Khait*, Muna Saleem Kalaf

View Publication Preview PDF
Publication Date
Sun Mar 13 2011
Journal Name
Baghdad Science Journal
Use of Coliphages as an indicators of enteroviruses and faecal pollution in Water
...Show More Authors

In spite of increasing clinical cases which caused by enteroviruses transferred by water and no documents about entericviruses in the Iraqi water standards. The use of coliphages as an indicator of enteroviruses and fecal pollution were suggested two procedures were applied . The first is Two-Step Enrichment Method and the second is Single Agar Layer Method. Both methods gives good results in Identification of coliphages through testing fifty different water samples (Tap water, Surface water and Bottled water) the study shows the presence of coliphages in fourteen samples.

View Publication Preview PDF
Crossref
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Engineering
Internal Convective Heat Transfer Effect on Iraqi Building Construction Cooling Load
...Show More Authors

This work involves the calculation of the cooling load in Iraqi building constructions taking in account the effect of the convective heat transfer inside the buildings. ASHRAE assumptions are compared with the Fisher and Pedersen model of estimation of internal convective heat transfer coefficient when the high rate of ventilation from ceiling inlet configuration is used. Theoretical calculation of cooling load using the Radiant Time Series Method (RTSM) is implemented on the actual tested spaces. Also the theoretical calculated cooling loads are experimentally compared by measuring the cooling load in these tested spaces. The comparison appears that using the modified Fisher and Pedersen model when large ventilation ra

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 01 2022
Journal Name
International Journal Of Research In Social Sciences And Humanities
THE EFFECT OF SPECIAL EXERCISES IN THE DEVELOPMENT OF THE MOMENTARY BIOMECHANICAL STRENGTH OF THE SKILL OF THE TWO REAR AIR CORES ON THE PARALLEL DEVICE IN THE TECHNICAL GYMNASTICS OF THE EMERGING PLAYERS
...Show More Authors

Gymnastics is one of the most interesting games in terms of organizing various world championships and tournaments. Their basic skills and their technical development, especially those with high difficulty levels that rely on basic and complex skills, are the basic skills of gymnastics are the main pillar to be developed and therefore high-difficulty skills will not depend on basic skills, which should reach the stage of the automatic mechanism. Retention) in order to move on to training and developing another skill for the difficulty of movements as well as the smooth flow of performance, ie the degrees of difficulty of each skill specific to your gym and The researcher used the experimental method and The research community determin

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 07 2024
Journal Name
F1000research
Oral pre-treatment with Citronellol ameliorates Methotrexate-induced nephrotoxicity in Wistar rats via targeting oxidative stress and inflammation
...Show More Authors

Background Methotrexate (MTX) is a classical folic acid antagonist widely used in the treatment of malignant and non-malignant disorders. However, its clinical application is often restricted by concomitant adverse effects, including renal damage. Numerous studies have highlighted the role of oxidative stress and inflammation in mediating MTX-related nephrotoxicity. Therefore, the current study aimed to explore the possible renoprotective action of Citronellol (CT), a natural compound with prominent antioxidant and anti-inflammatory activities, against nephrotoxicity induced by MTX. Methods To fulfill our objective, 24 adult male Wistar rats were randomly allocated into four groups: control, MTX, 100 mg/kg CT plus MTX and 200 mg/kg C

... Show More
Crossref (1)
Crossref