Preferred Language
Articles
/
joe-935
Experimental Investigation of Thermal Performance of a Solar Chimney Provided with a Porous Absorber Plate
...Show More Authors

 

Experimental investigation of the influence of inserting the metal foam to the solar chimney to induce natural ventilation are described and analyzed in this work. To carry out the experimental test, two identical solar chimneys (without insertion of metal foam and with insertion of metal foam) are designed and placed facing south with dimensions of length× width× air gap (2 m× 1 m× 0.2 m). Four incline angles are tested (20o,30o,45o,60o) for each chimney in Baghdad climate condition (33.3o latitude, 44.4o longitude) on October, November, December 2018. The solar chimney performance is investigated by experimentally recording absorber plate and air temperatures and velocity of air. Results indicated that the using metal foam absorber plate lead to reducing the mean temperature of absorber plate by 6.7 °C as a result, the values of chimney outlet air temperature increased. The daily solar chimney efficiency enhanced by 58.7% and the useful energy received also increased. The existence of metal foam caused higher air velocity at the exit and increasing in the ventilation rate that the maximum ventilate rate obtained from the solar chimney is 5.96 1/hr for 27 m3 volume of room at solar irradiance of 730 W/m2   for chimney incline angle of 60o. The results of the experimental work show that the addition of metal foam to the solar chimney as an absorber plate is an efficient method to enhance the characteristics of heat transfer and the thermal performance of the solar chimney in the weather condition of Iraq.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon May 18 2026
Journal Name
Heat Transfer
A Comparative Review of Conventional Mechanical and Solar‐Driven Cooling Technologies: Performance and Environmental Perspectives
...Show More Authors
ABSTRACT<p>Conventional cooling systems are major energy consumers in hot climates, directly contributing to increased carbon emissions and placing a significant strain on Iraq's national electricity grid. This study aims to explore and evaluate clean and sustainable alternatives to conventional systems. The methodology is based on a comparative analysis of various cooling technologies, including mechanical, absorption, adsorption, drying, and hybrid systems, using key performance indicators such as the coefficient of performance (COP), energy consumption, carbon emissions, and system cooling capacity. The results show that innovative solar cooling technologies offer superior operational effi</p> ... Show More
View Publication
Scopus Crossref
Publication Date
Sat Dec 01 2012
Journal Name
Journal Of Engineering
Numerical and experimental investigation on the performance of the capillary tube using R-134a and R-600a
...Show More Authors

In this paper, isobutane (R-600a) is used as a suitable substitute for (R-134a) when changing the length of capillary tube. And the experimental data on capillary tube are obtained under different conditions such as (subcooling and ambient temperatures) on domestic refrigerator (9ft3 size), this data shows that (R-600a) a suitable substitute for (R134a) .The test presented a model for a steady state, two-phase flow in capillary tube for vapour compression system .The numerical model depends on conservation equations (mass, energy and momentum) as wall as the equation of state for refrigerant. The solution methodology was implemented by using finite difference techniques. The system results indicate that it is possible to change the refri

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Jan 18 2022
Journal Name
Heat Transfer
Effect of receiver geometry on the optical and thermal performance of a parabolic trough collector
...Show More Authors
Abstract<p>In this study, the optical and thermal performance of a Parabolic Trough Collector PTC system is investigated theoretically. A series of numerical simulations and theoretical analysis has been conducted to investigate the effect of the receiver geometry and location relative to the focal line on its optical performance. The examined receiver geometries are circular, square, triangular, elliptical and a new design of circular‐ square named as channel receiver. The thermal performance of PTC is studied for different flow rates from (0.27 to 0.6 lpm) theoretically. Results showed that the best optical design is the channel receiver with an optical efficiency of 84% while the worst is the elliptical </p> ... Show More
View Publication
Scopus (20)
Crossref (15)
Scopus Crossref
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
The effect of changing the evacuated tube tilt angle and the fluid of the solar collector on the performance of a hybrid solar air conditioning system
...Show More Authors

In the hybrid coolingsolar systems , a solar collectoris used to convertsolar energy intoheat sourcein order to super heat therefrigerant leave thecompressor,andthisprocess helpsin the transformation ofrefrigerant state from gaseous statetothe liquid statein upper two-thirdsof thecondenserinstead of the lower two-thirdssuchas in thetraditional air-conditioning systems and this willreduce theenergyneeded torun the process ofcooling.In this research two hybrid air-conditioning system with an evacuated tube solar collector were used, therefrigerant was R22 and the capacity was 2 tons each.The tilt angle of the evacuated tube solar collector was changed and the solar collector fluid was replaced into oil instead of water.A comparison wasi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Feb 26 2026
Journal Name
Int. J. Corros. Scale Inhib.
DFT and experimental investigation of a novel 1,2,4-triazole derivative as a corrosion inhibitor for carbon steel A106 G/B in HCl solution
...Show More Authors

This work introduces a newly synthesized triazole derivative, 5-([(2-furanyl)methyl]-thiomethyl)-4-(naphtha-2-yl)-3-hydroxyl-4H-1,2,4-triazole (FTNT), as an effective corrosion inhibitor for carbon steel A106 G/B in 0.1 M HCl solution. The structure of the novel derivative was confirmed by FTIR, 1 H NMR, and 13 C NMR spectra. Potentiodynamic polarization measurements reveal that FTNT markedly suppresses corrosion, with inhibition efficiency reaching 81.6% at 600 ppm. Thermodynamic analysis indicates spontaneous, physisorption/chemisorption-augmented adsorption of FTNT on the steel surface, best described by the Freundlich isotherm. Atomic force microscopy (AFM) surface examination demonstrated that a protective FTNT coating precipitated on

... Show More
Publication Date
Fri Dec 31 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
AN EXPERIMENTAL STUDY OF THE EFFECT OF VORTEX GENERATOR ON THE FLAT-PLATE BOUNDARY LAYER: AN EXPERIMENTAL STUDY OF THE EFFECT OF VORTEX GENERATOR ON THE FLAT-PLATE BOUNDARY LAYER
...Show More Authors

This paper is dealing with an experimental study to show the influence of the geometric characteristics of the vortex generators VG son the thickness of the boundary layer (∂) and drag coefficients (CD) of the flat plate. Vortex generators work effectively on medium and high angles of attack, since they are "hidden" under the boundary layer and practically ineffective at low angles.

            The height of VGs relative to the thickness of the boundary layer enables us to study the efficacy of VGs in delaying boundary layer separation. The distance between two VGs also has an effect on the boundary layer if we take into

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Applied Thermal Engineering
Experimental evaluation of thermal efficiency, electrical efficiency, and power production of low-concentrating photovoltaic-thermal system with micro-jet channel
...Show More Authors

The efficient behavior of a low-concentrating photovoltaic-thermal system with a micro-jet channel (LCPV/T-JET) and booster mirror reflector is experimentally evaluated here. Micro-jets promote the thermal management of PV solar cells by implementing jet water as active cooling, which is still in the early stages of development. The booster mirror reflector concentrates solar irradiance into solar cells and improves the thermal, electrical, and combined efficiencies of the LCPV/T-JET system. The LCPV/T-JET system was tested under ambient weather conditions in the city of Bangi, Selangor, Malaysia, and all data was recorded between 10:00 a.m. and 4:00 p.m. Parametric studies were conducted to compare the performance of the LCPV/T-JET system

... Show More
View Publication
Scopus (27)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
NUMERICAL INVESTIGATION OF NATURAL CONVECTION RADIATION AND MAGNETOHYDRODYNAMIC IN VERTICAL POROUS CYLINDRICAL CHANNEL
...Show More Authors

A numerical study has been carried out to investigate heat transfer by natural convection and radiation under the effect of magnetohydrodynamic (MHD) for steady state axisymmetric twodimensional laminar flow in a vertical cylindrical channel filled with saturated porous media. Heat is generated uniformly along the center of the channel with its vertical surface remain with cooled constant wall temperature and insulated horizontal top and bottom surfaces. The governing equations which used are continuity, momentum and energy equations which are transformed to dimensionless equations. The finite difference approach is used to obtain all the computational results using the MATLAB-7 programming. The parameters affected on the system are Rayl

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jan 31 2019
Journal Name
Journal Of Engineering
Experimental Study of Solar Still Under Influence of Various Conditions
...Show More Authors

In the present work, experimental tests was done to explain the effect of insulation and water level on the yield output. Linear basin, single slope solar still used to do this purpose. The test was done from May to August 2017 in Mosul City-Iraq (Latitude: Longitude: Elevation: 200 m, and  South-East face). Experimental results showed that the yield output of the still increased by 20.785% and 19.864% in case of using thermal insulation at 4cm and 5cm respectively, also the yield output decrease by 15.134% as the water level increase from 4 to 5cm, with the presence of insulation and 14.147% without it. It has been conclude that the insulation and water level play important role in the process of passive

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Sep 30 2011
Journal Name
Al-khwarizmi Engineering Journal
Steady State Performance Investigation of a Three Phase Induction Motor Running Off Unbalanced Supply Voltages
...Show More Authors

The objective of this work is to investigate the performance of a conventional three phase induction motor supplied by unbalanced voltages. An effort to study the motor steady state performance under this disturbance is introduced. Using per phase equivalent circuit analysis with the concept of symmetrical components approach, the steady state performance is theoretically calculated. Also, a model for the induction motor with the MATLAB/Simulink SPS tools has been implemented and steady state results were obtained. Both results are compared and show good correlation as well. The simulation model is introduced to support and enhance electrical engineers with a complete understanding for the steady state performance of a fully loaded induc

... Show More
View Publication Preview PDF