Effect of Air Bubbles on Heat Transfer Coefficient in Turbulent Convection Flow
...Show More Authors

Experimental and numerical studies have been conducted for the effect of injected air bubbles on the heat transfer coefficient through the water flow in a vertical pipe under the influence of uniform heat flux. The investigated parameters were water flow rate of (10, 14 and 18) lit/min, air flow rate of (1.5, 3 and 4) lit/min for subjected heat fluxes of (27264, 36316 and 45398) W/m2. The energy, momentum and continuity equations were solved numerically to describe the motion of flow. Turbulence models k-ε was implemented. The mathematical model is using a CFD code Fluent (Ansys15). The water was used as continuous phase while the air was represented as dispersed. phase. The experimental work includes design, build and instrument a test rig for that purpose. A
circular vertical copper pipe test section of (length=0.7m, diameter= 0.05m, thickness= 1.5mm) is . designed and constructed, heated by an electrical heater fixed on its outer surface. Water . temperature at inlet is kept constant at (32°C). Water inlet and outlet temperatures, as well as radial temperature distribution within the pipe at seven sections along it between pipe surface and its center are measured. The results revealed that the secondary flow created by air bubbles have
significant effects on heat transfer enhancement and temperature profile. It is observed, that averaged Nusselt number enhancement for low heat flux of 27264 W/m2 and 4 lit/min air bubbles was 33.3 % and 23% in numerical and experimental, respectively.

 
 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Mechanical Engineering Research And Developments
Numerical investigation for Natural Convection in a square Enclosure with partially active thermal sides' wall
...Show More Authors

Three-dimensional cavity was investigated numerical in the current study filled with porous medium from a saturated fluid. The problem configuration consists of two insulated bottom and right wall and left vertical wall maintained at constant temperatures at variable locations, using two discretized heaters. The porous cavity fluid motion was represented by the momentum equation generalized model. The present investigation thermophysical parameters included the local thermal equilibrium condition. The isotherms and streamlines was used to examine energy transport and momentum. The meaning of changing parameters on the established average Nusselt number, temperature and velocity distribution are highlighted and discussed.

Scopus
Publication Date
Thu Nov 02 2023
Journal Name
Journal Of Engineering
Numerical Simulation of the Thermal Performance of a Tubular Solar Air Heater
...Show More Authors

In this work, a flat-plate solar air heater (FSAH) and a tubular solar air heater (TSAH) were designed and tested numerically. The work investigates the effect of increasing the contact area between the flowing air and the absorber surface of each heater and predicts the expected results before the fabrication of the experimental rig. Three-dimensional two models were designed and simulated by the ANSYS-FLUENT 16 Program. The solar irradiation and ambient air temperature were measured experimentally on December 1st 2022, at the weather conditions of Baghdad City- Iraq, at three air mass flow rates, 0.012 kg/s, 0.032 kg/s, and 0.052 kg/s. The numerical results showed the advantage in the thermal performance of

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 31 2025
Journal Name
Kerbala Journal Of Pharmaceutical Sciences
Determination of Methionine Via Chemiluminescence-Continuous Flow Injection Analysis
...Show More Authors

The research work represent a fast and simple method for the determination of methionine using chemiluminescence for the methionine-sodium hydroxide-luminol for the generation of a chemiluminesecent derivative of luminal. The emission was measured by continuous flow analysis made sample size of 83µL was used.Response versus concentration extended from 0.2-20 mM.L-1 with a percentage linearity of 96.17% or with 99.17% percentage of linearity for the range 0.6-20 mM.L-1. Reaching to a L.O.D. at (S/N=3) for 5 µM.L-1 from the gradual dilution for the minimum concentration in the calibration graph with a repeatability of less than 0.5% (n=10). A comparison was made between the new developed method with the classical method for the spectrophoto

... Show More
View Publication
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
INTERACTION EFFECTS OF HYDRODYNAMICALLY FULLY DEVELOPED PRIMARY FLOW AND SECONDARY FLOW IN THE THERMAL ENTRANCE REGION OF ANNULAR DUCT
...Show More Authors

Experiments have been conducted to study the local and average heat transfer by mixed
convection for hydrodynamically fully developed, thermally developing and fully developed
laminar upward air flow in an inclined annulus with adiabatic inner cast iron tube and uniform
heated outer aluminum tube with an aspect ratio ( Ω = 0.72) and (L/Dh≈40) for both calming and
test sections). A wide range of Reynolds number from 859 to 2024 has been covered, and heat
flux has been varied from 159 W/m2 to 812 W/m2 (these values of heat flux and Reynolds
number gave Richardson number range from 0.03 to 0.٣٨), with angles of annulus inclination
φ =0o (horizontal position), φ =60o (inclined position), and φ =90o (vertical posi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 31 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of plasma treatment on shear bond strength of soft denture liner with two different types of denture base material (heat cure and light cure)
...Show More Authors

Background: In this study we evaluate the effect of plasma treatment (oxygen and argon) gas in two different exposure times on the surface of heat cure and light cure acrylic resin. Materials and method: 100 specimens of heat cure and light cure acrylic resin were fabricated. The measurements of the samples were (75mm, 25mm and 4.5mm) length, width and depth respectively with stopper of 3mm depth. Two types of gas used oxygen and argon in (5,10) min by using (DC-glow discharge plasma device) then we apply cold cure soft lining material, with the help of Instron machine we test the shear stress value. Results: A highly significant effect after argon and oxygen gases treatment in both 5 and 10 min exposure times on shear bond strength to soft

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 31 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of thermocycling and different pH of artificial saliva on the impact and transverse strength of heat cure resin reinforced with silanated ZrO2 nano-fillers.
...Show More Authors

Background: The aim of this study was to evaluate the effect of thermo cycling and different pH of artificial saliva (neutral, acidic, basic) on impact and transverse strength of heat cure acrylic resin reinforced of with 5% silanated ZrO2 nano fillers. Materials and methods: 120 samples were prepared, 60 samples for impact strength test and another 60 samples for transverse strength test, for each test, samples were divided into two major groups (before and after thermo cycling), then each of these major groups were further subdivided into 3 subgroups according to the pH of prepared artificial saliva (neutral, acidic, basic). Charpy impact device was used for impact strength test and Flexural device was used for transverse strength test. R

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 25 2022
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The impact of the cash flow statement indicators in market value change of the industrial firms listed on the Palestine Stock Exchange
...Show More Authors

This research aims to examine the ability of impact of the cash flow statement indicators in the change in the market value of the industrial firms listed on the Palestine Stock Exchange. The research population consisted of (13) firms during the period (2015-2020). Data were collected from the annual financial statements of the firms. The research relies on the Pooled effects model to analyze the cross-section data (Panel Data), and the multiple regression method to test the hypotheses. The research finds a positive significant impact of (the ratios of cash flows from operating activities to sales, the return on assets from operating cash flows, and cash flows from operating activities to total current liabilities) in the change

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 14 2022
Journal Name
Physica Scripta
A wavelet-based collocation technique to find the discontinuous heat source in inverse heat conduction problems
...Show More Authors
Abstract<p>This paper is devoted to an inverse problem of determining discontinuous space-wise dependent heat source in a linear parabolic equation from the measurements at the final moment. In the existing literature, a considerably accurate solution to the inverse problems with an unknown space-wise dependent heat source is impossible without introducing any type of regularization method but here we have to determine the unknown discontinuous space-wise dependent heat source accurately using the Haar wavelet collocation method (HWCM) without applying the regularization technique. This HWCM is based on finite-difference and Haar wavelets approximation to the inverse problem. In contrast to othe</p> ... Show More
View Publication
Scopus (18)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Tue Aug 16 2022
Journal Name
Heat Transfer
Experimental study on thermo‐hydraulic performance of metal foam twisted tape in a double pipe heat exchanger
...Show More Authors
Abstract<p>A recent study compared experimentally the hydraulic and thermal activity of twisted tape inserts for two types, metal foam twisted tape (MFTT) and traditional twisted tape (TTT), in a double pipe heat exchanger. The investigation goal of the innovatively designed MFTT is to enhance the heat transfer process, which provides a higher thermal enhancement factor over those of TTT under the same conditions. Heat transfer activity in terms of Nusselt number (<italic>Nu</italic>) and Nusselt number ratio (<italic>Nu</italic>/<italic>Nu</italic><sub>o</sub>) as the heat exchanger equipped with the proposed MFTT and TTT inserts with various tape‐twist ratios (<i></i></p> ... Show More
View Publication
Scopus (10)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
Calculation the mass attenuation coefficient of beta-particles through Polyvinyl chloride
...Show More Authors

The mass attenuation coefficient for beta particles through pure Polyvinyl chloride (PVC) and flax fibers- reinforced PVC composite were investigated as a function of the absorber thickness and the absorber to source distance. The beta particles mass attenuation coefficients were obtained using a NaI(Tl) energy selective scintillation counter with 90Sr/ 90Y beta source having an energy range from (0.546-2.275) MeV. Pure PVC polymer samples were prepared by compacting the PVC powder in a mould at high pressure (10bar) and temperature about 140°C for 30 minutes. A hot press system was used for this process. The experimentally obtained values of mass attenuation coefficients for 90Sr and 90Y were found to be 7.72 cm2.g-1and 0.842 cm2.g-1 r