Reducing global warming potential (GWP) of refrigerants is needed to the decrease of ozone-depleting of refrigeration systems leakages. Refrigerant R1234yf is now used to substitute R134a inside mobile air conditioning systems. Thermodynamic properties of R1234yf are similar to R134a. Also, it has a very low GWP of 4, compared to 1430 for R134a, making it a proper choice for future automobile refrigerants. The purpose of this research is to represent the main operating and performance differences between R1234yf and R134a. Experimental analysis was carried out on the automotive air conditioning system (AACS) with 3 kW nominal capacity, to test and compare the performance of R134a with R1234yf. Experiments were accomplished for both refrigerants in almost the same working conditions and procedure with a range of ambient temperature varied from 26oC to 50oC. Parameters studied were ambient temperature, type of refrigerant in the system at compressor speed 1450 rpm, and internal thermal loads of passenger room. The performance characteristics of the system, including COP and cooling capacity, were studied by changing different parameters. The results show that COP of R134a is higher than R1234yf by 12.6%, while the refrigeration effect of R134a is higher than R1234yf by 25%. This shows that R1234yf is a suitable and good candidate for drop-in replacement of R134a in AACS.
Heat transfer around a flat plate fin integrated with piezoelectric actuator used as oscillated fin in laminar flow has been studied experimentally utilizing thermal image camera. This study is performed
for fixed and oscillated single and triple fins. Different substrate-fin models have been tested, using fins of (35mm and 50mm) height, two sets of triple fins of (3mm and 6mm) spacing and three frequencies
applied to piezoelectric actuator (5, 30 and 50HZ). All tests are carried out for (0.5 m/s and 3m/s) in subsonic open type wind tunnel to evaluate temperature distribution, local and average Nusselt number (Nu) along the fin. It is observed, that the heat transfer enhancement with oscillation is significant compared to without o
Expected to The organizational commitment by employees increases their loyalty towards their organization and thus contribute to enhancing their performance , therefore this study aimed to discover the relationship and the impact between the organizational commitment (emotional commitment, standard commitment, continuous commitment) and the performance of employees in the company researched, additional to know the available organizational commitment levels of employees in the company researched and its impact on the performance of employees, Research was conducted at the General Company for products in the dairy to achieve the goals of research has been developed questionnaire conation (22 ) items to collect data from the study s
... Show MoreA field experiment was carried out during the 2020 season at the College of Agricultural Engineering/ University of Baghdad, Al-Jadriya to evaluate the effect of dry farming when applying water stress under the subsurface drip irrigation system on water productivity and rice yield. The experiment was conducted with three levels of irrigation water stress when 10, 20 and 40% of the available water was depleted and in three dimensions between drip lines 10, 15 and 20 cm. The experiment was designed according to a randomized complete block design, according to the split plot design, with three replications. Determine the depth of irrigation water depending on the moisture depletion of th
A gracious invitation was extended to us on 9/11/2002 AD, by the University of Tikrit / the Preparatory Committee, for a symposium (Sheikh Daoud Al-Tikriti, and his Scientific Effects), to participate in it.
The symposium was scheduled to be held on the 25th and 26th of March 2003 AD, but God Almighty decreed that our country be occupied, so the Preparatory Committee set another date for the symposium on 10/21/2003 AD.
It was not possible for the symposium to be held until 25-26/4/2004 AD, and many researchers attended, who were assigned to investigate some manuscripts of Sheikh Dawood (may God have mercy on him) or to write about his personal and scientific biography.
And God (Glory be to Him) did not enable us to attend, becau
The self-awareness interactions reflects with emotions,assess the child in respect to its relations with the social standards; they are not merely simply reactions , but rather they connect with his moral behavior and other 's thinks. When the self- awareness gets developed with emotions within the child , the latter become highly sensitive, causing him prone to be blamed . AS a result , the children test the self –awareness interactions with emotions and in age 3 years , where the self –awareness interactions with emotion clearly link to the self- assessment. The children in stage of kindergarten could not describe the self-awareness interactions accurately ; they test it under different circumstances in comparison to the youngest o
... Show MoreObjectives: The current study aims at identifying the level of perceived stress among nursing college students and determining the factors associated with stress they have. Methodology: A cross-sectional descriptive study initiated for the period on November 1st, 2014 to May 1st, 2015. The study has been conducted on the undergraduate nursing college students / University of Baghdad. The sample of the study was consisted of (128) students who were selected purposively. The questionnaire of the study was adopted and modified for the present study which consisted of socio-demographic data and the scale of
In this work, an inventive photovoltaic evaporative cooling (PV/EC) hybrid system was constructed and experimentally investigated. The PV/EC hybrid system has the prosperous advantage of producing electrical energy and cooling the PV panel besides providing cooled-humid air. Two cooling techniques were utilized: backside evaporative cooling (case #1) and combined backside evaporative cooling with a front-side water spray technique (case #2). The water spraying on the front side of the PV panel is intermittent to minimize water and power consumption depending on the PV panel temperature. In addition, two pad thicknesses of 5 cm and 10 cm were investigated at three different water flow rates of 1, 2, and 3 lpm. In Case #1,
... Show MoreThe research aims to shed light on the nature of the tax gap in the income tax by the method of direct deduction and its reflection on the financial objective of the tax, and to determine the reasons for this gap in the deduction between the tax due in accordance with the laws and instructions in force and the tax actually paid. The tax gap is a real problem that cannot be ignored for what it represents loss of financial revenues due to the state.
The research problem is represented in the existence of a gap between the tax due according to direct deduction instructions and the tax actually paid according to the financial statements, and to achieve the objectives of the research and test the hypotheses, t
... Show MoreUse Almtafr axis to study the response component that isolates gave a positive response to the use of standard Almtafr which leads to lower the temperature and the number of cells at a temperature suitable Rifampicin resistant less than that TJ and similarly reflected on the frequency of mutations induced