Preferred Language
Articles
/
joe-637
Accuracy Assessment of Various Resolutions Digital Cameras For Close Range Photogrammetry Applications
...Show More Authors

Due to the great evolution in digital commercial cameras, several studies have addressed the using of such cameras in different civil and close-range applications such as 3D models generation. However, previous studies have not discussed a precise relationship between a camera resolution and the accuracy of the models generated based on images of this camera. Therefore the current study aims to evaluate the accuracy of the derived 3D buildings models captured by different resolution cameras. The digital photogrammetric methods were devoted to derive 3D models using the data of various resolution cameras and analyze their accuracies. This investigation involves selecting three different resolution cameras (low, medium and high) and evaluating their calibration accuracies. Assessing the accuracy of the three selected cameras in capturing indoor and outdoor objects; and analyzing the accuracy and the quality of the produced models. The study revealed that:1) It is recommended to use the photos of a high-resolution camera for producing precise 3D models of objects in the outdoor environment especially when the camera/object distance is more than 40 m because the accuracy of the  produced models can be  precise (RMSE ±10.36mm) with excellent quality; 2) The Low-resolution camera can be utilised to produce adequate 3D models of object in the indoor environment (RMSE ±6.32mm) especially when the camera/object distance is less than 40 m.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Nov 21 2019
Journal Name
Journal Of Engineering
Assessment of Observed Building Structure Setback of Shops along an Arterial Road and Noise Intrusion Level
...Show More Authors

Roads irrespective of the type have specific standard horizontal distance measured at 90 degrees from a lot boundary to a development known as a setback. Non-observance of the recommended setbacks accommodated in any urban center’s master plan creates noise hazard to the public health and safety as the movement of vehicular traffic is not without the attendant noise. This study assessed noise intrusion level in shops along a section of Ibadan-Abeokuta road with due consideration to compliance with the recommended building structure setback. Analysis of noise descriptors evaluated in this study gave A-weighted equivalent sound pressure level average of 91.3 dBA, the daytime average sound level (LD) 92.27 dBA,

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Sep 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Environmental Assessment of Polycyclic Aromatic Hydrocarbon Concentrations in Air at Thermal South Power Station of Baghdad
...Show More Authors

Sixteen polycyclic aromatic hydrocarbons (PAHs) concentrations were measured in aerosol samples collected for the period from April 2012 to February 2013 at thermal south power station of Baghdad. Fourty one aerosol sample were extracted with (1:1) dichloromethane and methanol using soxhlet for seventeen hour. The extraction solution was analyzed applying GC/MS. The PAH concentrations outside thermal south power station were higher than those inside it, and higher in summer season than in winter. Naphthalene, pyrene, Anthracene, Indeno [1, 2, 3-cd] pyrene and Phenanthrene were the most abundant PAHs detected in all points at the site sampling. The total polycyclic aromatic hydrocarbon (TPAH) and total suspended particles (TSP) concentrat

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 01 2021
Journal Name
Journal Of Engineering
Assessment of the Cost and Time Impact of Variation Orders on Construction Projects in Sulaimani Governorate
...Show More Authors

Variation orders are an on-going phenomenon in construction and industry projects worldwide, particularly in the province of Sulaimani, where the project's damage from cost and schedule overrun because of variation orders. However, the effect on project costs and time overrun of variation order has yet to be identified. This study evaluates the impact of variation orders on the cost and time off in the Sulaimani governorate. Two hundred twenty-eight projects from various construction sectors built between 2007-2012 were adopted to calculate the contract cost and schedule overruns due to variation orders. Data analysis was applied in the study were descriptive statistics. One-way ANOVA was also applied to determine w

... Show More
View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Tue Aug 11 2020
Journal Name
Bdj Open
An in vitro assessment of the physical properties of manually- mixed and encapsulated glass-ionomer cements
...Show More Authors
Abstract<sec> <title>Objectives

The last decade has seen a variety of modifications of glass-ionomer cements (GICs), such as inclusion of bioactive glass particles and dispensing systems. Hence, the aim was to systematically evaluate effect of mixing modes and presence of reactive glass additives on the physical properties of several GICs.

Materials and methods

The physical properties of eight commercial restorative GICs; Fuji IX GP Extra (C&H), KetacTM Fill Plus Applicap (C&H), Fuji II LC (C&H), Glass Carbomer Ce

... Show More
View Publication Preview PDF
Scopus (32)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Thu Apr 29 2021
Journal Name
International Journal Of Pavement Engineering
An assessment of lime-cement stabilisation on the elastic and resilient moduli of a clayey soil
...Show More Authors

View Publication
Scopus (9)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Sun Sep 15 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of surface microhardness of enamel surface treated with Nano- HAP serum before and after bleaching
...Show More Authors

Background: Although bleaching is typically considered a safe procedure, various investigations have found minor negative effects and changes in mineral composition. The aim was to Evaluate and compare the efficacy of using Nanohydroxyapatite serum on surface microhardness of enamel surface before and after bleaching with chemically cured Boost bleaching. Material and methods: ten sound human permanent upper and lower premolar teeth were used and their roots were removed 2 mm apically to the cementoenamel junction, the crowns were sectioned mesiodistally into two halves buccal and lingual/palatal, the buccal surface was further subdivided into two halves. The samples were embeded in an acrylic resin, resulting in 30 specimens divide

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Iop Conference Series: Earth And Environmental Science
Effluent Quality Assessment Monitoring of Al-Rustamiya Sewage Treatment Plant Using Geographical Information System (GIS)
...Show More Authors
Abstract<p>Water quality assessment offers a scientific basis for water resource development and management. This research aims to assessment of Al-Rustamiya sewage treatment plant depending on annually changes and produces maps that declare changes on parameter during a period (2015-2018). Based on prior Government Department Baghdad Environment data which annually feature changes for samples from Northern Rustamiya have been estimated as a working model. Drawn a map of the Diyala River shows annual changes in the characteristics of the Diyala River, based on northern and southern Rustamiya effluent samples, and Diyala River samples. The characteristics that research focused on were biochemical</p> ... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Crossref
Publication Date
Thu Feb 12 2026
Journal Name
Journal Of Baghdad College Of Dentistry
An Assessment of Oral Health in Hypertensive Patients Treated with HMG-CoA Reductase Inhibitors (Statins)
...Show More Authors

Background: Hypertension is a chronic medical condition in which the blood pressure in the arteries is elevated, it's classified as either primary (essential) hypertension or secondary hypertension, and it increases the risk of ischemic heart disease, peripheral vascular disease and other cardiovascular diseases. Several classes of medications collectively referred to as antihypertensive drugs like beta blockers, calcium channel blockers, angiotensin converting enzyme (ACE) inhibitors, angiotensin receptor blockers, renin inhibitors and statins (HMG-CoA) reductase inhibitor. Statin medication may have some beneficial effects when subjects have dental plaque or signs of periodontitis as gingival bleeding. The purpose of this study were to as

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 01 2019
Journal Name
Environmental Earth Sciences
Urban geochemistry assessment using pollution indices: a case study of urban soil in Kirkuk, Iraq
...Show More Authors

View Publication
Crossref (6)
Crossref
Publication Date
Sun Dec 30 2012
Journal Name
Al-kindy College Medical Journal
Assessment of High Sensitivity C.Reactive Protein in male patients with metabolic syndrome and atherosclerosis complications
...Show More Authors

Background: syndrome X or metabolic syndrome is a collection of multiple diseases mainly visceral obesity , hypertriglyceridemia , decrease HDL level, hypertension and elevated fasting blood glucose that lead to accelerated atherosclerosis through multiple mechanisms, one of the most important is increase inflammation of the vessels manifested by elevated high sensitivity C reactive protein (hs-CRP).Objective: The aim of the study was to assess the prevalence of elevatedhs CRP in people with metabolic syndrome and atherosclerosis complication (IHD, Cerebrovascular disease, peripheral vascular disease) and metabolic syndrome without these complication.Patients and methods:;This is a cross sectional study carried out in Diabetic referral c

... Show More
View Publication Preview PDF