Preferred Language
Articles
/
joe-634
Desalting of RO Waste and Drainage Water by Direct Contact Membrane Distillation
...Show More Authors

Direct contact membrane distillation is an effective method for production of fresh water from saline water. In this study two samples were used as feed solutions; the first one was RO waste from Al-Hilla Coca-Cola Factory (TDS= 2382 mg/l) and the other was Haji Ali drainage water (TDS= 4127 mg/l). Polytetrafluoroethylene (PTFE) hydrophobic membrane supported with polypropylene (PP) was used as flat sheet form with plate and frame cell. Results proved that membrane distillation is an effective technique to produce fresh water with high quality from brine with low salinity content. With membrane area of 8x8 cm2, the volume of treated water decreased from 34.97 ml at first half hour to 33.02 ml after 180 min of an experiment for first feed type and from 36.92 ml to 33.84 ml for the second feed type due to the fouling accumulated on the membrane surface. The temperature on both sides of the membrane surface and TDS of permeate was measured every 30 min of experiment time, also some tests were made on feed and permeate ions. Time of experiment was 180 min with the same operating conditions. 

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Nov 05 2013
Journal Name
Wit Transaction On Ecology And The Environments, Wit, Press No. 11
Remote sensing of water quality index for irrigation usability of the Euphrates River
...Show More Authors

irrigation use at many stations along the Euphrates River inside the Iraqi lands and to try to correlate the results with the satellite image analyses for the purpose of making a colored model for the Euphrates that can be used to predict the quality classifications of the river for irrigation use at any point along the river. The Bhargava method was used to calculate the water quality index for irrigation use at sixteen stations along the river from its entrance to the Iraqi land at Al-Qaim in Anbar governorate to its union with the Tigris River at Qurna in Basrah governorate. Coordinates of the sixteen stations of the Euphrates River were projected at the mosaic of Iraq satellite image which was taken from LANDSAT satellite for bands 1, 2

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 14 2024
Journal Name
Iraqi Journal Of Industrial Research
Corrosion Behaviour, Kinetic and Thermodynamic Studies of Water Hyacinth Extract as a Corrosion Inhibitor for Low-Carbon Steel
...Show More Authors

Corrosion inhibitors are widely used in industry to reduce the corrosion rate of metals and alloys. Corrosion inhibitors adsorb onto metallic surfaces and insulate them from deterioration. Plants abundant in nature offer a cost-effective replacement for toxic chemical inhibitors on the market. The current research used the potentiostatic polarization technique at room temperature to explore the inhibitory impact of water hyacinth extract on the corrosion of low-carbon steel specimens in a 3.5% NaCl solution. The Tafel curve was used to assess corrosion inhibition activity, with the best inhibition efficiency reaching 79.36% at a concentration of 200 ppm. Cyclic polarization indicated the type of corrosion was general corrosion. The

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Wed Oct 01 2008
Journal Name
Journal Of Engineering
WATER QUALITY INDICES FOR TIGRIS RIVER IN BAGHDAD CITY
...Show More Authors

Due to the deterioration of water quality within the last few years because of the increase of water consumption and the waste water production and disposal into the river The water quality in both surface and ground water resources was negatively affected .The concept of water quality index is used as a tool for water quality classification in Tigris River within Baghdad City .Twenty two parameters of pollution were selected to measure the water quality indices of Tigris river within Baghdad city .Those parameters were measured during (2000-2004)as average monthly values ,three water treatment plants were selected out of the eight water treatment plants that exist along the river.Al Kharkh water treatment plant to reflect the water quality

... Show More
View Publication
Publication Date
Thu Apr 25 2019
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
MEASUREMENT OF CHEMICAL AND PHYSICAL PROPERTIES IN SOME MINERAL WATER SAMPLES FILLED IN THE MARKETS OF THE PROVINCE OF NAJAF AND COMPARE WITH THE IRAQI AND INTERNATIONAL RATIOS.: MEASUREMENT OF CHEMICAL AND PHYSICAL PROPERTIES IN SOME MINERAL WATER SAMPLES FILLED IN THE MARKETS OF THE PROVINCE OF NAJAF AND COMPARE WITH THE IRAQI AND INTERNATIONAL RATIOS.
...Show More Authors

In this research, a selection of some mineral water was selected on the basis of being the most marketed by the owners of shops in Najaf province, with six types, where daily samples of this water were taken by 50 ml for two months from (1/11/2018 -1/1/2019). The following ions concentrations were measured (Br-, Cl-, F-, NO3-, SO42-, Na+, K+, Ca2+, Mg2+), pH and the electrical conductivity were measured and the results were compared with the allowable rates according to the international organizations. It was noted that they conform to international and Iraqi standards.

View Publication Preview PDF
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Adaptive digital technique for discriminating between shadow and water bodies in the high resolution satellite imagery
...Show More Authors

This research presents a new algorithm for classification the
shadow and water bodies for high-resolution satellite images (4-
meter) of Baghdad city, have been modulated the equations of the
color space components C1-C2-C3. Have been using the color space
component C3 (blue) for discriminating the shadow, and has been
used C1 (red) to detect the water bodies (river). The new technique
was successfully tested on many images of the Google earth and
Ikonos. Experimental results show that this algorithm effective to
detect all the types of the shadows with color, and also detects the
water bodies in another color. The benefit of this new technique to
discriminate between the shadows and water in fast Matlab pro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Iraqi Journal Of Physics
Measurement of Background Radioactivity in Baghdad's Main Water Supply Stations: Sediment Samples
...Show More Authors

Sediment samples were collected from main water processing and supply plants in Baghdad, and tested for radioactivity from both natural and artificial sources. These stations are: East Dijla (Tigris), Al-Kadisia, Al-Karama, Al-Rasheed, Al-Sader, Al-Wathba, and Al-Wihda supply stations. Qualitative measurements were made, and the results showed that most sediments exhibited natural radioactive level and sometimes less than the international regular standards. Specially, K-40 and Ra-226 results were much less than the standards for radioactive concentrations. Ac-228 concentration was found rather than Th-232 (in Al-Sader and Al-Wihda samples) but with low concentrations of about 10-15 Bg/kg and detection confidence ~45% , and Ce-141 and Be

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 07 2014
Journal Name
Baghdad Science Journal
A Study Of Corrosion Behavior Of Low Carbon Steel In Acidic And Basic Washing Water Of Crude Oil Solution At Different Temperatures
...Show More Authors

The corrosion behavior of low carbon steel in washing water of crude oil solution has been studied potentiostatically at five temperatures in the range ( 303 –343 )K, at pH ( 4 ) and at pH (4,6,7,9,11 ) at (343K)..The corrosion potential shifted to more negative values with increasing temperature and the corrosion current density increased with increasing temperature, the corrosion current density (icorr) decreased with increasing pH in the rang ( 4 – 7 ) and it increased with increasing pH in the rang ( 9 – 11 ) at ( 343 K ), while the corrosion potential generally variation with increasing pH in the rang (4-11)at(343K. From the general results for this study can be seen that thermodynamic and kinetic function were

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Mar 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Factors Affecting the Absorption of Ozone in Water
...Show More Authors

This study was concerned with using ozone gas in drinking water treatment plant at Ibn-Sina Company. The main purpose of this research is to find the best contactor for ozone unit proposed. An investigation was conducted to study the absorption of ozone by water in two type of absorber. The effects of the process variables (such as height of water column, contact time, and pH) on the amount of ozone absorbed were investigated. Box-Wilson central composite rotatable design is used to design the experimental work for the mentioned variables. It was found that the optimum value of the variables studied was:
i) Height of water column (90 cm)
ii) Contact time (17-18 min)
iii) PH (7 - 7.5)

View Publication Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
Scholars' Press
Determination of Pollutants in Water Treatment for Petroleum Refinery
...Show More Authors

Dora petroleum refinery waste water is the one of the important source of pollution by priority pollutant aromatic compound discharged to Tigris river in Iraq. the station has waste water treatment unit contains many treatment subunits The most important sub units is :skimmer units ,physiochemical unit ,daf unit, biological unit. The aim of research project is to study the ability of unit to remove the priority pollutant aromatic compound and follow up these compounds in river to study ability of river to self removal. A solid phase extraction (SPE) followed by high performance liquid chromatography-ultra violet (HPLC-UV) technique is depicted for the quantitative estimation of benzidines and phenols. Experimental studies were performed to

... Show More
Publication Date
Mon Dec 01 2008
Journal Name
Al-khwarizmi Engineering Journal
Extraction of Phenol From Industrial Water Using Different Solvents
...Show More Authors

The analysis and efficiency of phenol extraction from the industrial water using different solvents, were investigated. To our knowledge, the experimental information available in the literature for liquid-liquid equilibria of ternary mixtures containing the pair phenol-water is limited. Therefore the purpose of the present investigation is to generate the data for the water-phenol with different solvents to aid the correlation of liquid-liquid equilibria, including phase diagrams, distribution coefficients of phenol, tie-lines data and selectivity of the solvents for the aqueous phenol system.

                The ternary equilibrium diagrams and tie-lines

... Show More
View Publication Preview PDF