Preferred Language
Articles
/
joe-629
Experimental and Numerical Analysis of Expanded Pipe using Rigid Conical Shape
...Show More Authors

The experimental and numerical analysis was performed on pipes suffering large plastic deformation through expanding them using rigid conical shaped mandrels, with three different cone angles (15◦, 25◦, 35◦) and diameters (15, 17, 20) mm. The experimental test for the strain results investigated the expanded areas. A numerical solution of the pipes expansion process was also investigated using the commercial finite element software ANSYS. The strains were measured for each case experimentally by stamping the mesh on the pipe after expanding, then compared with Ansys results. No cracks were generated during the process with the selected angles. It can be concluded that the strain decreased with greater angles of conical shape and an increase in expansion ratio results in an increase of expansion force and a decrease in the pipe thickness and length resulting in pipe thinning and shortening. Good agreement is evident between experimental and ANSYS results within discrepancy (16.90017%) in the X direction and (27.68698%) in the Y direction. Also, the stress distribution is investigated and it can be concluded that the case of Diameter (Do cone) = 35mm and (A) = α = 15° is the optimum.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Aug 05 2019
Journal Name
Journal Of Engineering
Behaviour of Segmental Concrete Beams Reinforced by Pultruded CFRP Plates: an Experimental Study
...Show More Authors

Research aims to develop a novel technique for segmental beam fabrication using plain concrete blocks and externally bonded Carbon Fiber Reinforced Polymers Laminates (CFRP) as a main flexural reinforcement. Six beams designed an experimentally tested under two-point loadings. Several parameters included in the fabrication of segmental beam studied such as; bonding length of carbon fiber reinforced polymers, the surface-to-surface condition of concrete segments, interface condition of the bonding surface, and thickness of epoxy resin layers. Test results of the segmental beams specimens compared with that gained from testing reinforced concrete beam have similar dimensions for validations. The results show the effectiven

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Mon Dec 31 2018
Journal Name
International Journal Of English Linguistics
Iraqi EFL Students’ Difficulties in Writing Composition: An Experimental Study (University of Baghdad)
...Show More Authors

Iraqi EFL students face difficulties in writing composition, especially academic writing, which affects negatively their exam results. This study has been conducted in the Department of English at College of Education for Women, University of Baghdad, in order to identify first year EFL students’ incompetence in writing. This may enhance their achievement by some weekly writing activities. It deals with Iraqi EFL students’ difficulties in writing paragraphs such as descriptive, process, opinion, and factual paragraphs. The study aims to identify these difficulties and to suggest suitable solutions for them. The researcher perceives that it is necessary to enhance students’ skills in writing because it i

... Show More
View Publication
Crossref (8)
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Experimental Study of Forced- Convection from Horizontal Rectangular Fins Array into Air Duct
...Show More Authors

    In this work, an experimental study has been done to expect the heat characteristics and performance of the forced-convection from a heated horizontal rectangular fins array to air inside a rectangular cross-section duct. Three several configurations of rectangular fins array have been employed. One configuration without notches and perforations (solid) and two configurations with combination of rectangular-notches and circular-perforations for two various area removal percentages from fins namely 18% notches-9% perforations and 9% notches-18% perforations are utilized.  The rectangular fins dimensions and fins number are kept constant. The fins array is heated electrically from the base

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 17 2017
Journal Name
Al-khwarizmi Engineering Journal
Experimental Simulation of Natural Heat Convection from Finned Vertical Plate with Different Inclinations
...Show More Authors

In this work an experimental simulation is made to predict the performance of steady-state natural heat convection along heated finned vertical base plate to ambient air with different inclination angles and configurations of fin array. Two types of fin arrays namely vertical fins array and V-fins array on heated vertical base plate are used with different heights and spaces. The influence of inclination angle of the plate , configuration of fins array and fin geometrical parameters such as fin height and fin spacing on the temperature distribution, base convection heat transfer coefficient and average Nusselt number have been plotted and discussed. The experimental data are correlated to a formula between average Nusselt number versus R

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 01 2022
Journal Name
Civil Engineering Journal
Calibration of a New Concrete Damage Plasticity Theoretical Model Based on Experimental Parameters
...Show More Authors

The introduction of concrete damage plasticity material models has significantly improved the accuracy with which the concrete structural elements can be predicted in terms of their structural response. Research into this method's accuracy in analyzing complex concrete forms has been limited. A damage model combined with a plasticity model, based on continuum damage mechanics, is recommended for effectively predicting and simulating concrete behaviour. The damage parameters, such as compressive and tensile damages, can be defined to simulate concrete behavior in a damaged-plasticity model accurately. This research aims to propose an analytical model for assessing concrete compressive damage based on stiffness deterioration. The prop

... Show More
Scopus (35)
Crossref (32)
Scopus Clarivate Crossref
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
Synthesis, Characterization, Thermal Analysis and Structural Studies of New Complexes with Tetradentate Ligand
...Show More Authors

Some new complexes of 4-(5-(1,5-dimethyl-3-oxo-2-phenyl pyrazolidin-4- ylimino)-3,3-dimethyl cyclohexylideneamino) -1,5- dimethyl-2- phenyl -1H- pyrazol -3(2H) –one (L) with Mn(II), Fe(III), Co(II), Ni(II), Cu(II), Pd(II), Re(V) and Pt(IV) were prepared. The ligand and its metal complexes were characterized by phisco- chemical spectroscopic techniques. The spectral data were suggested that the (L) as a neutral tetradentate ligand is coordinated with the metal ions through two nitrogen and two oxygen atoms. These studies revealed Octahedral geometries for all metal complexes, except square planar for Pd(II) complex. Moreover, the thermodynamic activation parameters, such as ?E*, ?H, ?S, ?G and K are calculated from the TGA curves using Coa

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Apr 01 2016
Journal Name
Journal Of Engineering
Experimental Behavior of Steel-Concrete-Steel Sandwich Beams with Truss Configuration of Shear Connectors
...Show More Authors

This paper presents experimentally a new configuration of shear connector for Steel-Concrete-Steel (SCS) sandwich beams that is derived from truss configuration. It consists of vertical and inclined shear connectors welded together and to cover steel plates infilled with concrete. Nine simply supported SCS beams were tested until the failure under a concentrated central load (three- point bending). The beams were similar in length (1100mm), width (100mm), and the top plate thickness (4mm). The test parameters were; beam thickness (150, 200, 250, and 300mm), the bottom plate thickness (4, and 6mm), the diameter of the shear connectors (10, 12, and 16mm), and the connector spacing (100, 200, and 250mm). The test results sh

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Thermal Science
Experimental investigation of the thermal performance of wet cooling tower with splash fills packing
...Show More Authors

With the increasing intensity of the ecological and environmental problems and the scarcity of fresh water, this paper was introduced to investigate the ability to use treated wastewater as a cooling media via studying its behavior throughout a cooling tower. The simultaneous transfer of heat and mass from the treated wastewater to air over splash-fill packing arranged in a zigzag manner was studied. The characteristic of the cooling tower, the outlet water temperature, and the rejected heat were investigated as the water-to-air ratio and inlet water temperature were varied. The core results show that the cooling tower of the tower decreases with increasing water-to-air ratio, and increases with the raise of inlet water temperature.

... Show More
View Publication
Scopus (12)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Dose-dependent Anti-inflammatory Effect of Silymarin in Experimental Animal Model of Acute Inflammation
...Show More Authors

Silymarin, a flavolignans from seeds of ‘milk thistle’ “Silybum marianum” has been widely used from ancient times because of its excellent hepatoprotective action. It has been used clinically to treat liver disorders including acute and chronic viral hepatitis, toxin/drug-induced hepatitis and cirrhosis and alcoholic liver disease. The efficacy and dose-response effect of silymarin (125, 250 and 500 mg/kg) were assessed using egg albumin-induced paw edema in rats as a model of acute inflammation. In this model, 56 rats were used and allocated into 7 subgroups each containing 8 rats. All treatments were given intraperitonealy 30 minutes before induction of inflammation by egg albumin and then the increase

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jan 01 2015
Journal Name
Journal Of Engineering
Experimental Study of the effect of closed cavity wall on buildings cooling loads saving
...Show More Authors

The experimental study showed the use of closed cavity wall (the thickness of the cavity 5cm) made a percentage reduction in the cooling load caused by heat gain from the wall by (21.5 %) compared with the conventional wall. also the thermal resistance of the closed cavity was an average (0.2 m2.oC/W).

The experimental results of the study showed that the use of closed cavity wall reduced the average temperature of the inner surface of the wall during the day, and that the reduction was an average (0.45 oC)  when compared with the conventional wall , as well as the use of closed cavity wall reduced the temperature difference range of the inner surface of the wall during the day, and that the

... Show More
View Publication