Preferred Language
Articles
/
joe-614
The Effect of Circular Perforation on a V-Corrugated Fin Performance under Natural Convection
...Show More Authors

An experimental investigation has been made to study the influence of using v-corrugated aluminum fin on heat transfer coefficient and heat dissipation in a heat sink. The geometry of fin is changed to investigate their performance. 27 circular perforations with 1 cm diameter were made. The holes designed into two ways, inline arrangement and staggered in the corrugated edges arrangement. The experiments were done in enclosure space under natural convection. Three different voltages supplied to the heat sink to study their effects on the fins performance. All the studied cases are compared with v-corrugated smooth solid fin. Each experiment was repeated two times to reduce the error and the data recorded after reaching the steady state conditions. The results showed that the v-corrugated fin dissipate heat twice and triple times than flat plate mentioned in past research with the same dimension. Also, the inline perforated fin gave higher enhancement percentage than solid one by 15, 32 and 36% for 110, 150 and 200 V voltages supplied. Finally, the staggered perforation arrangement gave the higher enhancement percentage with 22, 42 and 45% for the same voltages supply.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
The effect of changing the evacuated tube tilt angle and the fluid of the solar collector on the performance of a hybrid solar air conditioning system
...Show More Authors

In the hybrid coolingsolar systems , a solar collectoris used to convertsolar energy intoheat sourcein order to super heat therefrigerant leave thecompressor,andthisprocess helpsin the transformation ofrefrigerant state from gaseous statetothe liquid statein upper two-thirdsof thecondenserinstead of the lower two-thirdssuchas in thetraditional air-conditioning systems and this willreduce theenergyneeded torun the process ofcooling.In this research two hybrid air-conditioning system with an evacuated tube solar collector were used, therefrigerant was R22 and the capacity was 2 tons each.The tilt angle of the evacuated tube solar collector was changed and the solar collector fluid was replaced into oil instead of water.A comparison wasi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 23 2022
Journal Name
Innovative Infrastructure Solutions
Experimental modeling of a single pile in liquefiable soil under the effect of coupled static-dynamic loads
...Show More Authors

In this work, a single pile is physically modeled and embedded in an upper liquefiable loose sand layer overlying a non-liquefiable dense layer. A laminar soil container is adopted to simulate the coupled static-dynamic loading pile response during earthquake motions: Ali Algharbi, Halabjah, El-Centro, and Kobe earthquakes. During seismic events with combined loading, the rotation along the pile, the lateral and vertical displacements at the pile head as well as the pore pressure ratio in loose sandy soil were assessed. According to the experimental findings, combined loading that ranged from 50 to 100% of axial load would alter the pile reaction by reducing the pile head peak ground acceleration, rotation of the pile, and lateral displacem

... Show More
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Mon Dec 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Experimental Study on the Impact of External Geometrical Shape on Free and Forced Convection Time Dependent Average Heat Transfer Coefficient during Cooling Process
...Show More Authors

In this research, an experimental study was conducted to high light the impact of the exterior shape of a cylindrical body on the forced and free convection heat transfer coefficients when the body is hold in the entrance of an air duct. The impact of changing the body location within the air duct and the air speed are also demonstrated. The cylinders were manufactured with circular, triangular and square sections of copper for its high thermal conductivity with appropriate dimensions, while maintaining the surface area of all shapes to be the same. Each cylinder was heated to a certain temperature and put inside the duct at certain locations. The temperature of the cylinder was then monitored. The heat transfer coefficient were then cal

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
Determination of Skip Entry Trajectories for Space Vehicles at Circular and Super Circular Speeds
...Show More Authors

The study of entry and reentry dynamics for space vehicles is very important, particularly for manned vehicles and vehicles which is carry important devices and which can be used again. There are three types for entry dynamic, ballistics entry, glide entry and skip entry. The skip entry is used in this work for describing entry dynamics and determining trajectory. The inertia coordinate system is used to derive equations of motion and determines initial condition for skip entry. The velocity and drag force for entry vehicle, where generate it during entry into earth’s atmosphere are calculated in this work. Also the deceleration during descending and determining entry angles, velocities ratio and altitude ratio have been studied. The c

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
An Experimental Study of the Effect of Vortex Shedding on Solar Collector Performance
...Show More Authors

In this work, the effect of vortex shedding on the solar collector performance of the parabolic trough solar collector (PTSC) was estimated experimentally. The effect of structure oscillations due to wind vortex shedding on solar collector performance degradation was estimated. The performance of PTSC is evaluated by using the useful heat gain and the thermal instantaneous efficiency. Experimental work to simulate the vortex shedding excitation was done. The useful heat gain and the thermal efficiency of the parabolic trough collector were calculated from experimental measurements with and without vortex loading. The prototype of the collector was fabricated for this purpose. The effect of vortex shedding at different operation condition

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Effect the Natural Lighting In The Visual Comfort & Workers Satisfaction in Industrial Companies
...Show More Authors

Energy crisis and the requirements of health and feel good, all this renewed attention to the importance of natural lighting in all kinds of factories.
    Research problem was how to achieve the plant's own natural outlets visual comfort and satisfaction of workers in
Companies, the industries of cotton and general al-fedaa.

     The research compuns address the impact of daylight to provide visual comfort in the factory. Indeed, the light must be treated very carefully, and natural lighting should be thinking from the perspective of the occupants of the plant and not wishing to view from the outsid

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Aug 15 2019
Journal Name
Selcuk Journal Of Agriculture And Food Sciences
The Effect of Knife Clearance on the Machine Performance in Disc Type Silage Machines
...Show More Authors

In this study, active knife and fixed knife of single-row disc silage machine has three different clearance C1, C2 and C3 (1, 3 and 5 mm) and it is tried in three different working speed V1, V2 and V3 (1.8, 2.5 and 3.7 km / h) and PTO speed (540 min-1) and machine's fuel consumption (l/h), average power consumption (kW), field energy consumption (kW/da), product energy consumption (kW/t), field working capacity (da/h), product working capacity (t/h) and Chopping size distribution characteristics of the fragmented material were determined. It has been found that knife-counter knife clearances smaller than 3 mm (1 mm) and larger (5 mm) have a negative effect on machine performance in general. In terms of fuel and power consumptions, the m

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 08 2023
Journal Name
Iraqi Journal Of Laser
PDF The effect of nanoelectrodes number and length on enhancing the THz photomixer performance
...Show More Authors

Abstract: Despite the distinct features of the continuous wave (CW) Terahertz (THz) emitter using photomixing technique, it suffers from the relatively low radiation output power. Therefore, one of effective ways to improve the photomixer emitter performance was using nanodimensions electrodes inside the optical active region of the device. Due to the nanodimension sizes and good electrical conductivity of silver nanowires (Ag-NWs), they have been exploited as THz emitter electrodes. The excited surface plasmon polariton waves (SPPs) on the surface of nanowire enhances the incident excitation signal. Therefore, the photomixer based Ag-NW compared to conventional one significantly exhibits higher THz output signal. In thi

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 22 2018
Journal Name
Journal Of Economics And Administrative Sciences
Performance Appraisal of Human Resource Management and Its Effect on Achieving the Organizational Success -A Field Search at the Ministry of Oil-
...Show More Authors

The present study addressed "Performance Appraisal of Human Resource Management and Its Effect on Achieving the Organizational Success", for the topics of performance appraisal of human resource management and the organizational success gained an increasing interest being relatively important and modern topics which had a great effect on the future of organizations.

The study aimed at revealing the pattern of appraising the performance of human resource management for the study sample, and whether it was qualified to lead the ministry towards the organizational success, for this purpose two main hypotheses were formulated: 1) there is a positive significant correlation between both variables: performanc

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Oct 15 2024
Journal Name
Civileng
Structural Performance of a Hollow-Core Square Concrete Column Longitudinally Reinforced with GFRP Bars under Concentric Load
...Show More Authors

Concrete columns with hollow-core sections find widespread application owing to their excellent structural efficiency and efficient material utilization. However, corrosion poses a challenge in concrete buildings with steel reinforcement. This paper explores the possibility of using glass fiber-reinforced polymer (GFRP) reinforcement as a non-corrosive and economically viable substitute for steel reinforcement in short square hollow concrete columns. Twelve hollow short columns were meticulously prepared in the laboratory experiments and subjected to pure axial compressive loads until failure. All columns featured a hollow square section with exterior dimensions of (180 × 180) mm and 900 mm height. The columns were categorized into

... Show More
View Publication
Scopus (4)
Crossref (5)
Scopus Clarivate Crossref