Preferred Language
Articles
/
joe-543
Numerical Simulation of Thermal-Hydrodynamic Behavior within Solar Air Collector
...Show More Authors

Solar collectors, in general, are utilized to convert the solar energy into heat energy, where it is employed to generate electricity. The non-concentrating solar collector with a circular shape was adopted in the present study. Ambient air is heated under a translucent roof where buoyant air is drawn from outside periphery towards the collector center (tower base). The present study is aimed to predict and visualize the thermal-hydrodynamic behavior for airflow under inclined roof of the solar air collector, SAC. Three-dimensional of the SAC model using the re-normalization group, RNG, k−ε turbulence viscus model is simulated. The simulation was carried out by using ANSYS-FLUENT 14.5. The simulation results demonstrated that at same insolation; airflow, ground and air temperatures increase when the collector radius decreases towards the collector center. The ground temperature and air velocity increase, while airflow temperature decreases when the inclination angle increases from 0° to 20° due to changing in airflow movement. More decreasing in airflow temperature has been occurred when the inlet height increases from 0.1m to 0.25m. The simulation results were validated by comparing with the experimental data. In conclusions, the obtained results showed the capability of producing warm airflow to generate electricity in Baghdad city.  

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed May 29 2019
Journal Name
Iraqi Journal Of Physics
Weathering effects on the thermal conductivity of PS/PMMA blends for packaging application
...Show More Authors

This work describes the weathering effects (UV-Irradiation, and Rain) on the thermal conductivity of PS, PMMA, PS/PMMA blend for packaging application. The samples were prepared by cast method at different ratios (10, 30, 50, 70, and 90 %wt). It was seen that the thermal conductivity of PMMA (0.145 W/m.K), and for PS(0.095 W/m.K), which increases by PS ratio increase up to 50% PS/PMMA blend then decreased that was attributed to increase in miscibility of the blend involved. By UV-weathering, it was seen that thermal conductivity for PMMA increased with UV-weathering up to (30hr) then decreased, that was attributed to rigidity and defect formation, respectively. For 30%PS/PMMA, there results showed unsystematic decrease in thermal conduct

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2010
Journal Name
Advances In Condensed Matter Physics
Electrical and Optical Properties of :H Thin Films Prepared by Thermal Evaporation Method
...Show More Authors

Thin a-:H films were grown successfully by fabrication of designated ingot followed by evaporation onto glass slides. A range of growth conditions, Ge contents, dopant concentration (Al and As), and substrate temperature, were employed. Stoichiometry of the thin films composition was confirmed using standard surface techniques. The structure of all films was amorphous. Film composition and deposition parameters were investigated for their bearing on film electrical and optical properties. More than one transport mechanism is indicated. It was observed that increasing substrate temperature, Ge contents, and dopant concentration lead to a decrease in the optical energy gap of those films. The role of the deposition conditions on value

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Structural and electrical properties of tellurium thin films prepared by vacuum thermal deposition
...Show More Authors

Thin films of highly pure (99.999%) Tellurium was prepared by high vacuum technique (5*10-5torr), on glass substrates .Thin films have thickness 0.6m was evaporated by thermal evaporation technique. The film deposited was annealed for one hour in vacuum of (5*10-4torr) at 373 and 423 K. Structural and electrical properties of the films are studies. The x-ray diffraction of the film represents a poly-crystalline nature in room temperature and annealed film but all films having different grain sizes. The d.c. electrical properties have been studied at low and at relatively high temperatures and show that the conductivity decreases with increasing temperature at all range of temperature. Two types of conduction mechanisms were found to d

... Show More
View Publication Preview PDF
Publication Date
Tue May 01 2018
Journal Name
Journal Of Physics: Conference Series
The Effects of micro Aluminum fillers In Epoxy resin on the thermal conductivity
...Show More Authors

View Publication
Scopus (34)
Crossref (22)
Scopus Clarivate Crossref
Publication Date
Thu Sep 01 2016
Journal Name
Applied Thermal Engineering
Solidification of a PCM with nanoparticles in triplex-tube thermal energy storage system
...Show More Authors

View Publication
Scopus (158)
Crossref (160)
Scopus Clarivate Crossref
Publication Date
Thu Sep 01 2016
Journal Name
Applied Thermal Engineering
Solidification of a PCM with nanoparticles in triplex-tube thermal energy storage system
...Show More Authors

Crossref (160)
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Aip Conference Proceedings
Modeling and analysis of thermal contrast based on LST algorithm for Baghdad city
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Engineering
A Mathematical Model of a Thermally Activated Roof (TAR) Cooling System Using a Simplified RC-Thermal Model with Time Dependent Supply Water Temperature
...Show More Authors

This paper presents a computer simulation model of a thermally activated roof (TAR) to cool a room using cool water from a wet cooling tower. Modeling was achieved using a simplified 1-D resistance-capacitance thermal network (RC model) for an infinite slab. Heat transfer from the cooling pipe network was treated as 2-D heat flow. Only a limited number of nodes were required to obtain reliable results. The use of 6th order RC-thermal model produced a set of ordinary differential equations that were solved using MATLAB - R2012a. The computer program was written to cover all possible initial conditions, material properties, TAR system geometry and hourly solar radiation. The cool water supply was considered time

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 01 2022
Journal Name
Iranian Journal Of Chemistry And Chemical Engineering
The Thermal Pre-processing Technique of the Bio-waste for Contaminated Water Treatment: Histological and Experimental Study
...Show More Authors

The current study suggested a thermal treatment as a necessary proactive step in improving the adsorption capacity of bio-waste for contaminants removal in wastewater. This approach was based on the experimental and histological investigation of biowaste pods shell. This investigation showed that these shells compose of parenchyma cells that store secondary metabolites compounds produced from cells were exhibited in present study. The results also reported that these compounds are extracted directly from the cells as soon as they are exposed to an aqueous solution, hampering their use as an adsorbent material. The increase in the weight of bio-waste adsorbent at unit liquid volume increases the production of secondary metabolites compounds

... Show More
View Publication
Publication Date
Sun Mar 06 2011
Journal Name
Baghdad Science Journal
Age,Growth and Reproduction of Zebra Mussel, Dreissena polymorpha in Al-Musayab Thermal Power Plant, Iraq
...Show More Authors

Some biological aspects of the zebra mussel, Dreissena polymorpha have been studied at Al-Musayab thermal power plant ,sixty km. south west of Baghdad. Data collected during the period extended from November, 2002 to October, 2003 except for the month of April The population consisted of five age groups; O, I, II, III, and IV which have 0, 1, 2, 3 and 4 annuli respectively. The study also proved the validity of annuli readings for age and growth determination. The average annual growth rates for age groups O,I, II, III, and IV were 5.7, 5.5, 5.4, 5.2 and 5.4 respectively. Average calculated length for laboratory reared mussel was 2.5 mm compared to 5.4 mm in natural environment. Correlation coefficients were very high between age an

... Show More
View Publication Preview PDF
Crossref