Impact Response for Two Designs of Athletic Prosthetic Feet
...Show More Authors

The present work evaluated the differences in mechanical properties of two athletic prosthetic feet samples when subjected to impact while running. Two feet samples designated as design A and B were manufactured using layers of different orientations of woven glass fiber reinforced with unsaturated polyester resin as bonding epoxy. The samples’ layers were fabricated with hand lay-up method. A theoretical study was carried out to calculate the mechanical properties of the composite material used in feet manufacturing, then experimental load-deflection  test was applied at 0 degree position and 25 degree dorsiflexion feet position  and impact test were applied for both feet designs to observe the behavior of the feet under static and impact loading and compare properties like stiffness, efficiency, rigidity, and shock absorption at different drop angles range from 25 degrees to 60 degrees which perform the foot positions while running. The load-deflection test result shows that the maximum deflection of the proposed design B was 32.2 mm at 0° and 38.45mm at 25°. While it was 41mm at 0˚ and 39mm at 25˚ for design A. Impact test result shows that design B foot gives peak load of 128 .7 kg with a peak time of 0.06 sec, while design Afoot gives 125.32 kg peak load with a time of 0.069 sec.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 10 2017
Journal Name
Assiut J. Agric. Sci.
The response of white eggplant plants to foliar application with boron and potassium silicate
...Show More Authors

Publication Date
Sun Nov 01 2020
Journal Name
Conference
Study the Response Of The Wind Turbine System under Realistic Working Conditions Using Simulink
...Show More Authors
Abstract<p>In recent years, there has been a very rapid development in the field of clean energy due to the huge increase in the demand, which prompted the manufacturers and the designers to increase the efficiency and operating life of the energy systems and especially for wind turbine. It can be considered that the control unit is the main key of the wind turbines. Consequently, it’s essential to understanding the working principle of this unit and spotlight on the factors which influence significantly on the performance of wind turbine system. Simulink technique is proposed to find the response of the wind turbine system under different working conditions. In this paper, it was investigated</p> ... Show More
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The extent of the industrial company's response to blue market strategy indicators: Applied research
...Show More Authors

The current research aims to describe the level of responsiveness and awareness of the officials of the General Company for Construction Industries to the indicators of the blue market strategy of (1. reduction 2. exclusion 3. increase 4. innovation) and the degree of prioritization according to their importance as well as the differences in the responses of the sample investigated according to the personal variables. As a main tool in the collection of data from the sample, which consisted of(34) officers (Associate, Manager, Section Manager, Division Officer) in the company being investigated, and computed mean, standard deviations, percentage weights,and test (x2 )  based on the SPSS. The research reached the following

... Show More
View Publication
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Engineering
The Response of Reinforced Concrete Composite Beams Reinforced with Pultruded GFRP to Repeated Loads
...Show More Authors

This paper investigates the experimental response of composite reinforced concrete with GFRP and steel I-sections under limited cycles of repeated load. The practical work included testing four beams. A reference beam, two composite beams with pultruded GFRP I-sections, and a composite beam with a steel I-beam were subjected to repeated loading. The repeated loading test started by loading gradually up to a maximum of 75% of the ultimate static failure load for five loading and unloading cycles. After that, the specimens were reloaded gradually until failure. All test specimens were tested under a three-point load. Experimental results showed that the ductility index increased for the composite beams relative to the reference specim

... Show More
Crossref (10)
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Engineering
The Response of Reinforced Concrete Composite Beams Reinforced with Pultruded GFRP to Repeated Loads
...Show More Authors

Publication Date
Tue Dec 13 2022
Journal Name
Mathematical Modelling Of Engineering Problems
Dynamic Response and Reliability Analysis of Stochastic Multi-Story Frame Structures under Random Excitation
...Show More Authors

In earthquake engineering problems, uncertainty exists not only in the seismic excitations but also in the structure's parameters. This study investigates the influence of structural geometry, elastic modulus, mass density, and section dimension uncertainty on the stochastic earthquake response of a multi-story moment resisting frame subjected to random ground motion. The North-south component of the Ali Gharbi earthquake in 2012, Iraq, is selected as ground excitation. Using the power spectral density function (PSD), the two-dimensional finite element model of the moment resisting frame's base motion is modified to account for random ground motion. The probabilistic study of the moment resisting frame structure using stochastic fin

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Engineering
The Response of Reinforced Concrete Composite Beams Reinforced with Pultruded GFRP to Repeated Loads
...Show More Authors

This paper investigates the experimental response of composite reinforced concrete with GFRP and steel I-sections under limited cycles of repeated load. The practical work included testing four beams. A reference beam, two composite beams with pultruded GFRP I-sections, and a composite beam with a steel I-beam were subjected to repeated loading. The repeated loading test started by loading gradually up to a maximum of 75% of the ultimate static failure load for five loading and unloading cycles. After that, the specimens were reloaded gradually until failure. All test specimens were tested under a three-point load. Experimental results showed that the ductility index increased for the composite beams relative to the refe

... Show More
View Publication Preview PDF
Crossref (10)
Crossref
Publication Date
Sat Dec 31 2011
Journal Name
Al-khwarizmi Engineering Journal
The Estimation of Vibrational Energy of Two Coupled (Welded) Plates Using Statistical Energy Analysis
...Show More Authors

 

This paper deals with a method called Statistical Energy Analysis that can be applied to the mechanical and acoustical systems like buildings, bridges and aircrafts …etc. S.E.A as a tool can be applied to the resonant systems in the circumstances of high frequency or/and complex structure». The parameters of S.E.A such as coupling loss factor, internal loss factor, modal density and input power are clarified in this work ; coupled plate sub-systems and explanations are presented for these parameters. The developed system is assumed to be resonant, conservative, linear and there is an equipartition of energy between all the resonant modes within a given frequency band in a given sub-system. The aim of th

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
Response of green lacewing Chrysoperla carnea (Stephens) to various densities of Ephestia cautella (walk)eggs
...Show More Authors

Results of exposure larvae of the most important predator in the integrated pest management , the green lacewings, Chrysoperla carnea (Stephens) to various densities of fig moth Ephestia cautella eggs showed increasing in the number of consumed prey at decreasing rate of increasing prey density where curve slope consumption decreased gradually until leveling off. These specifications concurred with type II functional response that predators appear towards varied densities of its preys ,that was confirm by logistic regression between the proportion of prey eaten in relation to prey offered . Third larval instars of the predator showed attack rate (a) of 4.85. This was greater than the second larval instar (3.58). Handling time (Th) per

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Response of composite steel-concrete cellular beams of different concrete deck types under harmonic loads
...Show More Authors
Abstract<p>This study aims to investigate the adequacy of composite cellular beams with lightweight reinforced concrete deck slab as a structural unit for harmonic loaded buildings. The experimental program involved three fixed-ends supported beams throughout 2140 mm. Three concrete types were included: Normal Weight Concrete (NWC), Lightweight Aggregate Concrete (LWAC), and Lightweight Fiber Reinforced Aggregate Concrete (LWACF). The considered frequencies were (5, 10, 15, 20, 25, and 30) Hz. It was indicated that the harmonic load caused a significant influence on LWAC response (64% greater than NWC) and lattice cracks were observed, especially at 30 Hz. As for LWACF slab, no cracks appeared, </p> ... Show More
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref