Preferred Language
Articles
/
joe-394
Optimal Location of Static Synchronous Compensator (STATCOM) for IEEE 5-Bus Standard System Using Genetic Algorithm
...Show More Authors

Heuristic approaches are traditionally applied to find the optimal size and optimal location of Flexible AC Transmission Systems (FACTS) devices in power systems. Genetic Algorithm (GA) technique has been applied to solve power engineering optimization problems giving better results than classical methods. This paper shows the application of GA for optimal sizing and allocation of a Static Compensator (STATCOM) in a power system. STATCOM devices used to increase transmission systems capacity and enhance voltage stability by regulate the voltages at its terminal by controlling the amount of reactive power injected into or absorbed from the power system. IEEE 5-bus standard system is used as an example to illustrate the technique used. Results showed that the STATCOM was able to reduce the voltage deviation and the apparent power losses with minimum possible size of installation capacity for STATCOM devices. GA plays its own requirements by finding best location and best size of STATCOM devices.

 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Nov 27 2025
Journal Name
Bulletin Of The Chemical Society Of Ethiopia
Synthesis, characterization, dyeing performance, and microbial evaluation of 5-((2,4-dibromo-6-((cyclohexyl(methyl)amino) methyl)phenyl)diazenyl)quinolin-8-ol complexes with some metallic ions
...Show More Authors

5-((2,4-dibromo-6-((cyclohexyl(methyl)amino)methyl)phenyl)diazenyl)quinolin-8-ol azo ligand (L) has been synthesized through the reaction of diazonium salt for 2,4-dibromo-6-((cyclohexyl(methyl)amino)methyl)aniline with 8-hydroxyquinoline. The azo ligand (L) was characterized utilizing spectroscopic techniques, including FTIR, UV-Vis, 1H and 13C NMR, as well as mass spectrometry and micro-elemental analysis (C.H.N). Metal complexes containing Co(II), Ni(II), Cu(II), and Zn(II) were synthesized and analyzed through mass spectrometry, flame atomic absorption, elemental analysis (C.H.N), infrared and UV-Vis spectroscopy, along with measurements of conductivity and magnetic properties. The experimental findings suggested that all met

... Show More
View Publication
Scopus Crossref
Publication Date
Fri Feb 28 2020
Journal Name
Neuroquantology
Using X-Ray Films for Evaluation efficiency of Unsaturated Polyester Reinforced by Lead Oxide as Shielding for Medical X-ray Devices
...Show More Authors

The largest use of x-ray in medical by dentists, employers or persons that needed by patients with specific conditions, lead to higher exposure of x-ray that may cause many diseases. In the present work radiography films have been used in evaluating the efficiency of using unsaturated polyester polymer reinforced with lead oxide (PbO) as shield material for medical x-ray devices, many parameters studied like concentration and thickness that they are increasing the attenuation of x-ray in them. The results show that the attenuation of X-ray increasing with concentration of reinforced material and with thickness, and the optical density decreases with increasing concentration from 0% to 50%, we chose 30% as suitable concentration to increase

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Dec 06 2015
Journal Name
Baghdad Science Journal
Evaluating molecular study of the association of Glutathione S – Transferase GST (T1 , M1) genetic polymorphism in Iraqi Arab Femals with Type 2 Diabetes Mellitus and Coronary Artery Disease
...Show More Authors

Coronary artery disease (CAD) is a major health concern and leading of death in individuals with type 2 diabetes mellitus (T2DM). Glutathione S – Transferase(GST) are known for their broad range of detoxification and in the metabolism of xenobiotics . The role of functional variants of these genes in the development of various disorder is proven. We investigated the possible role of these variants in the development of CAD in T2DM patients. In this case – control study a total of 60 patients (T2DM = 30 ; T2DM – CAD = 30) and 30 controls were included. Serum lipid profiles were measured and DNA was extracted from the blood samples. Multiplex PCR for GSTT1/M1 (present / null) polymorphism, were performed for genotyping of study pa

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 15 2024
Journal Name
2024 International Conference On Distributed Computing And Optimization Techniques (icdcot)
Reconfigurable Microstrip Antenna Design Fifth Generation (5G) System
...Show More Authors

View Publication
Scopus (2)
Scopus Crossref
Publication Date
Sun Jun 03 2012
Journal Name
Baghdad Science Journal
On The Queuing System M/Er/1/N
...Show More Authors

In this paper the queuing system (M/Er/1/N) has been considered in equilibrium. The method of stages introduced by Erlang has been used. The system of equations which governs the equilibrium probabilities of various stages has been given. For general N the probability of j stages of service are left in the system, has been introduced. And the probability for the empty system has been calculated in the explicit form.

View Publication Preview PDF
Crossref
Publication Date
Mon Apr 15 2019
Journal Name
Proceedings Of The International Conference On Information And Communication Technology
Hybrid LDPC-STBC communications system based on chaos
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Sun Jun 12 2011
Journal Name
Baghdad Science Journal
Comparison between Direct and Coherent Optical Communication System
...Show More Authors

The work in this paper focuses on the system quality of direct and coherent communication system for two computers. A system quality is represented by Signal to Noise ratio (SNR) and Bit Error Rate (BER). First part of the work includes implementation of direct optical fiber communication system and measure the system quality .The second part of the work include implementation both the( homodyne and heterodyne)coherent optical fiber communication system and measure the system quality . Laser diode 1310 nm wavelength with its drive circuit used in the transmitter circuit . A single mode of 62.11 km optical fiber is selected as transmission medium . A PIN photo detector is used in the receiver circuit. The optical D-coupler was u

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Feb 09 2019
Journal Name
Journal Of The College Of Education For Women
The Turn-Taking System in American Presidential Debates
...Show More Authors

The organization and coordination of any communication is based on the system of turn-taking which refers to the process by which a participant in a conversation takes the role of speaker. The progression of any conversation is achieved by the change of roles between speaker and hearer which, in its turn, represents the heart of the turn-taking system. The turn-taking system is not a random process but it is a highly organized process governed by a set of rules. Thus, this system has certain features and rules which exist in any English communicative process. These rules, if applied by speakers, help to achieve successful exchange of turns in any conversation. This paper attempts to present full exposition of the concepts of conversation

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
COMPUTER-BASED ECG SIGNAL ANALYSIS AND MONITORING SYSTEM
...Show More Authors

This paper deals with the design and implementation of an ECG system. The proposed system gives a new concept of ECG signal manipulation, storing, and editing. It consists mainly of hardware circuits and the related software. The hardware includes the circuits of ECG signals capturing, and system interfaces. The software is written using Visual Basic languages, to perform the task of identification of the ECG signal. The main advantage of the system is to provide a reported ECG recording on a personal computer, so that it can be stored and processed at any time as required. This system was tested for different ECG signals, some of them are abnormal and the other is normal, and the results show that the system has a good quality of diagno

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 11 2019
Journal Name
Journal Of Mechanical Engineering Research And Developments
INDUSTRIAL TRACKING CAMERA AND PRODUCT VISION DETECTION SYSTEM
...Show More Authors

View Publication
Scopus (7)
Crossref (3)
Scopus Crossref