The ground level ozone concentration at different locations in Baghdad city was identified. Five
different sites have been chosen to identify the ground level ozone concentration. Al- Dora and Al-
Za'afarania were chosen as areas contained point source ( power plant station ) in addition to high traffic
load , while Al –Uma park, Aden square and Al-Mawal square were chosen as area contained heavy
traffic only (line source). The measurement focuses on spring and fall because these periods display
favorable meteorology to ozone formation. During the research period the maximum values (peaks) for
ground level ozone concentration were observed at fall: at Al-Za'afarania area 101ppb as an average, at
Al-Dora 87 ppb as an average and at line source areas 48 ppb as an average. Among the line sources area
Al-Mawal square represent the highest peak value at fall 68 ppb. At spring the peaks of ozone
concentration observed to be at the same height, 50 ppb for all sites. The downwind sites from the power
plant stations at Al-Dora and Al-Za'afarania areas record higher ozone peaks compared with up wind
sites. It can be concluded that the effect of power plant stations in forming ozone is larger than traffic
load.
The comparison between the ground level ozone concentrations that measured during the research period in spring and fall, and the ambient air quality standards (AAQS) shows that:
• No exceeded levels were observed in spring for all sites.
• In fall the AAQS for ozone was exceeded in Al-Za'afarania area at 12: PM, 1: PM, 2: PM and 3:
PM, and in Al-Dora at 2: PM.
Pure and Fe-doped zinc oxide nanocrystalline films were prepared
via a sol–gel method using -
C for 2 h.
The thin films were prepared and characterized by X-ray diffraction
(XRD), atomic force microscopy (AFM), field emission scanning
electron microscopy (FE-SEM) and UV- visible spectroscopy. The
XRD results showed that ZnO has hexagonal wurtzite structure and
the Fe ions were well incorporated into the ZnO structure. As the Fe
level increased from 2 wt% to 8 wt%, the crystallite size reduced in
comparison with the pure ZnO. The transmittance spectra were then
recorded at wavelengths ranging from 300 nm to 1000 nm. The
optical band gap energy of spin-coated films also decreased as Fe
doping concentra
Background: Oral squamous cell carcinoma represents the vast majority of oral cancer it is a common malignant tumor with an increasing incidence. Around the world, the 5 year mortality rate of oral cancer is about 50%. Thus novel biomarkers for early detection oral squamous cell carcinoma are needed. The level of three salivary microRNAs namely hsa-miR-200a, hsa-miR-125a and hsa- miR-93 were measured in saliva of patients with oral squamous cell carcinoma and compared their levels in saliva of healthy control subjects to determine their potential as oral cancer biomarker. Materials and methods: The level of these three microRNAs was measured by using revers transcription, preamplification and quantitative PCR. Results: Only miR-200a presen
... Show MoreThe aim of this article is to solve the Volterra-Fredholm integro-differential equations of fractional order numerically by using the shifted Jacobi polynomial collocation method. The Jacobi polynomial and collocation method properties are presented. This technique is used to convert the problem into the solution of linear algebraic equations. The fractional derivatives are considered in the Caputo sense. Numerical examples are given to show the accuracy and reliability of the proposed technique.
Abstract: Two different shapes of offset optical fiber was studied based on coreless fiber for refractive index (RI)/concentration (con.) measurement, and compare them. These shapes are U and S-shapes, both shapes structures were formed by one segment of coreless fiber (CF) was joined between two single mode (SMF) lead in /lead out with the same displacement (12.268µm) at both sides, the results shows the high sensitive was achieved in a novel S-shape equal 98.768nm/RIU, to our knowledge, no one has ever mentioned or experienced it, it’s the best shape rather than the U-shape which equal 85.628nm/RIU. In this research, it was proved that the offset form has a significant effect on the sensitivity of the sensor. Addi
... Show MoreBackground: Dental implants act as infrastructure for fixed restoration to look like as a natural tooth. Osseointegration is a biological events and considered as a base for success of dental implant. The aim of this study is to evaluate the bond strength between bone and Ti implant coated with mixture of nano hydroxyapatite-chitosan-collagen compared with Ti implants coated with nano hydroxyapatite implanted in rabbit tibia, after different period of implantation time (two and six weeks) by torque removal test. Material and methods: 36 screws of commercially pure titanium; 8mm in length and 3mm diameter , 18 screws coated with mixture of nano hydroxyapatite-chitosan-collagen and18 screws coated with nano hydroxyapatite by dip coating. St
... Show More