Preferred Language
Articles
/
joe-2986
EXPERIMENTAL INVESTIGATION OF LAMINAR NATURAL CONVECTION HEAT TRANSFER IN A RECTANGULAR ENCLOSURE WITH AND WITHOUT INSIDE PARTITIONS
...Show More Authors

Experimental study has been conducted for laminar natural convection heat transfer of air flow through a rectangular enclosure fitted with vertical partition. The partition was oriented parallel to the two vertical isothermal walls with different temperatures, while all the other surfaces of the enclosure were insulated. In this study a test rig has been designed and constructed to allow studying the effect of Rayleigh number, aperture height ratio, partition thickness, the position of aperture according to the side walls and according to the height, the position of the partition according to the hot wall, and partition inclination. The experiments were carried out with air as the working fluid for Rayleigh number range (5*107 – 1.3*108) and aspect ratio of (0.5). 22 different configurations of partition were used in this study these are:
a) Undivided enclosure (no – partition).
b) (21) Cork partitions of different shapes.
Empirical correlations for average Nusselt number are obtained for the different cases tested. The results show that heat transfer is independent on the partition position according to the cold wall and according to the upper or lower walls, while it shows that heat transfer is sensitive to:
1. Rayleigh number (Ra), which increase with increasing Ra.
2. Aperture height ratio (Ap=hp/H), which is found that when Ap= 5/6 (case 2,3), the reduction in heat transfer is 10.3%, while when Ap=1/2 (case 4,5), the reduction is 17.2% compared with the non partitioned enclosure.
3. Aperture position according to the height, which is found that when the aperture at the centre of the partition (case 13), the reduction in heat transfer is 16.7%, while when the aperture displaced to the upper surface (case 14), the reduction is 19% compared with the non partitioned enclosure.
4. Partition thickness (t), which is found that when t = 10 mm (case 4,5) the reduction in heat transfer is 17.2%, while when t = 150 mm (case 16) the reduction is 20.5% compared with the non partitioned enclosure.
5. Partition inclination (), which is found that the rate of heat transfer reduced with increasingas shown:
a. For = 30 toward the cold wall (case 22), the reduction in heat transfer is 18.2%.
b. For = 45 toward the cold wall (case 18), the reduction in heat transfer was 21.9%.
c. For = 60 toward the cold wall (case 20), the reduction in heat transfer is 30.2%.
d. For = 30 toward the hot wall (case 21), the reduction in heat transfer is 31.3%.
e. For = 45 toward the hot wall (case 17), the reduction in heat transfer is 40.7%.

f. For = 60 toward the hot wall (case 19), the reduction in heat transfer is 42.1%.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jul 01 2025
Journal Name
Mastering The Minds Of Machines
Unsupervised Learning: Discovering Patterns without Labels: Health Care, E-Commerce, and Cybersecurity
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Journal Of Engineering
Influence of Design Efficiency of Water Supply Network Inside Building on its Optimum Usage: Review
...Show More Authors

The water supply network inside the building is of high importance due to direct contact with the user that must be optimally designed to meet the water needs of users.  This work aims to review previous research and scientific theories that deal with the design of water networks inside buildings, from calculating the amount of consumption and the optimal distribution of the network, as well as ways to rationalize the use of water by the consumer.  The process of pumping domestic water starts from water treatment plants to be fed to the public distribution networks, then reaching a distribution network inside the building till it is  provided to the user.  The design of the water supply network inside the building is

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Aug 15 2023
Journal Name
Journal Of Current Researches On Social Sciences
An Examination of Discourse Investigation of Fallacies in Religious Texts: Islam as a Case Study
...Show More Authors

BN RASHİD, 2023

View Publication
Publication Date
Thu May 02 2013
Journal Name
Journal Of Engineering
Experimental and numerical analysis of piled raft foundation with different length of piles under static loads
...Show More Authors

In order to understand the effect of (length of pile / diameter of pile) ratio on the load carrying capacity and settlement reduction behavior of piled raft resting on loose sand, laboratory model tests were conducted on small-scale models. The parameters studied were the effect of pile length and the number of piles. The load settlement behavior obtained from the tests has been validated by using 3-D finite element in ABAQUS program, was adopted to understand the load carrying response of piled raft and settlement reduction. The results of experimental work show that the increase in (Lp/dp) ratio led to increase in load carrying capacity by piled raft from (19.75 to 29.35%), (14.18 to 28.87%) and (0 to 16.49%) , the maximum load carr

... Show More
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Experimental and Numerical Analysis of Piled Raft Foundation with Different Length of Piles Under Static Loads
...Show More Authors

In order to understand the effect of (length of pile / diameter of pile) ratio on the load carrying capacity and settlement reduction behavior of piled raft resting on loose sand, laboratory model tests were conducted on small-scale models. The parameters studied were the effect of pile length and the number of piles. The load settlement behavior obtained from the tests has been validated by using 3-D finite element in ABAQUS program, was adopted to understand the load carrying response of piled raft and settlement reduction. The results of experimental work show that the increase in (Lp/dp) ratio led to increase in load carrying capacity by piled raft from (19.75 to 29.35%), (14.18 to 28.87%) and (0 to 16.49%) , the maximum load carried

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon May 04 2020
Journal Name
Environmental Engineering Research
Experimental and modeling study of water defluoridation using waste granular brick in a continuous up-flow fixed bed
...Show More Authors

Contamination of surface and groundwater with excessive concentrations of fluoride is of significant health hazard. Adsorption of fluoride onto waste materials of no economic value could be a potential approach for the treatment of fluoride-bearing water. This experimental and modeling study was devoted to investigate for the first the fluoride removal using unmodified waste granular brick (WGB) in a fixed bed running in continuous mode. Characterization of WGB was carried out by FT-IR, SEM, and EDX analysis. The batch mode experiments showed that they were affected by several parameters including contact time, initial pH, and sorbent dosage. The best values of these parameters that provided maximum removal percent (82%) with the in

... Show More
Scopus (19)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Sat Dec 02 2023
Journal Name
Journal Of Engineering
The Cost of Technology Transfer in Construction Companies (In Iraq)
...Show More Authors

The construction sector is considered an important and influential pivot in the national economy of any country.  Nations are working to develop this sector, receiving modern and developed techniques. So, this sector can be a carrier or a receiver of modern technologies. The cost of technology transfer between the international companies that sponsor this sector is a matter of great importance, especially since different factors affect the need for this advanced technology. The cost of technology transfer in construction is related to multiple factors presented by Knowledge, equipment, plant, hardware and software. The lack of distinguishing and evaluating the direct and indirect costs in the construction sector during

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 04 2008
Journal Name
Journal Of Baghdad College Of Dentistry
Twelve months clinical comparison between modified Widman flap with or without enamel matrix derivative for the treatment of infrabony defects
...Show More Authors

Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
Using TermoDeck System for Pre-Cooling/ Heating to Control the Building Inside Conditions
...Show More Authors

In this paper, experimental study has been done for temperature distribution in space conditioned with Ventilation Hollow Core Slab (TermoDeck) system. The experiments were carried out on a model room with dimensions of (1m 1.2m 1m) that was built according to a suitable scale factor of (1/4). The temperature distributions was measured by 59 thermocouples fixed in several locations in the test room. Two cases were considered in this work,  the first one during unoccupied period at night time (without external load) and the other at day period with external load of 800W/m2 according to solar heat gain calculations during summer season in Iraq. All results confirm the use of TermoDeck system for ventilation and cooling/heat

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 28 2023
Journal Name
Engineering Applications Of Computational Fluid Mechanics
Comprehensive analysis of melting enhancement by circular Y-shaped fins in a vertical shell-and-tube heat storage system
...Show More Authors

View Publication
Scopus (58)
Crossref (24)
Scopus Clarivate Crossref