The research aims to apply the novel forward osmosis (FO) process to recover pure water
from contaminated water. Phenol was used as organic substance in the feed solution, while sodium
chloride salt was used as draw solution. Membranes used in the FO process is the cellulose
triacetate (CTA) and polyamide (thin film composite (TFC)) membrane. Reverse osmosis process
was used to treatment the draw solution, the exterior from the forward osmosis process. In the FO
process the active layer of the membrane faces the feed solution and the porous support layer faces
the draw solution and this will show the effect of dilutive internal concentration polarization and
concentrative external concentration polarization.
In the FO process was a run-time for five hours, and the concentration of phenol 100 and
1000 mg/l, and for the NaCl the concentration was 10000 and 30000 mg/l. It was found that
recovery percent increases with increasing time, while water flux through membrane decreases with
increasing time. Also, it was found that recovery and water flux increases with increasing draw
solution concentration, on the contrary, water flux and the percentage of recovery decreases with
increasing the concentration of phenol (feed solution). Increase in draw solute (NaCl) concentration
has more effect on the water flux in FO process compared with increase in the concentration of
phenol. Outlet phenol concentration increases with time, while the outlet salt concentration
decreases with increasing the time. The results showed that the cellulose triacetate membrane gave
the highest recovery ratio from the thin film composite membrane. The highest recovery was
reached in five hours is 51.33%, while using CTA membrane recovery rate increase, by 23%
compared with TFC membrane. The value of the resistance to solute diffusion within the membrane
porous support layer is 36.83 h/m. Reverse osmosis is perfect method for removal of dissolved salts
from water, thus its suitable process for reducing the content of NaCl in draw solution; therefore the
sodium chloride rejection percentage was 91.6 – 96 % for polyamide membrane (TFC). Within two
hours of work of the reverse osmosis system the recovery percentage of pure water is 58%.
The aim of research is to show the effect of Ferric Oxide (Fe2O3) on the electricity production and wastewater treatment, since 2.5% of Ferric Oxide (Fe2O3) (heated and non heated) nanoparticles has been used. Characterization of nanoparticles was done using X-ray Diffraction (XRD) and Scan Electron Microscopy (SEM). The influence of acidity was also studied on both wastewater treatmenton the Chemical Oxygen demand (COD) and Biological Oxygen Demand (BOD) and voltage output was studied. From the results, it was infused that the dosage of 0.025 g/l and an initial pH 7 were founded to be optimum for the effective degradation of effluents. The results concluded that the treatment of anaerobic sludge wastewater using Ferric Oxide (Fe2O3) in
... Show MoreBackground: the oral cavity is consider to be an open ecosystem, with the balance between the microorganism’s entrance and the defenses of the host. The initiation of periodontitis has been associated with restricted kinds of anaerobic bacteria, such as Aggregatibacter actinomycetemcomitans (A.a) and Porphyromonas gingivalis (P.g) in plaque subgingivally. Ozone has a biological effects on bacteria due to oxidation of bio-molecules and its toxins. The aim is to determine and compare the antimicrobial effect of gaseous ozone and ozonized water on the growth of isolated anaerobic bacteria (A.a and P.g) when exposed to different time intervals. Materials and methods:This experiment is done byozone generator OLYMPIC- III(600mg/hr) to gene
... Show MoreThe artificial intelligence techniques such as neural networks and fuzzy systems play an important role to disconnect flexion & expansion of the swing leg, the earth response force of the other foot has been redesigned. Under that paper, we think the fuzzy controller plan issue for yield following flawed genuine investigation of nonlinear systems. For examination, an essential fuzzy control plot has been bristly developed dependent on a current methodology delegate under the field. In this paper, the Feedforward Neural Network has been implemented with integer, fixed point and floating point data representations. Additionally, The Fuzzy Logic Controllers in both analog and digital forms has been implemented in hardware. Both designs use les
... Show MoreThe region-based association analysis has been proposed to capture the collective behavior of sets of variants by testing the association of each set instead of individual variants with the disease. Such an analysis typically involves a list of unphased multiple-locus genotypes with potentially sparse frequencies in cases and controls. To tackle the problem of the sparse distribution, a two-stage approach was proposed in literature: In the first stage, haplotypes are computationally inferred from genotypes, followed by a haplotype coclassification. In the second stage, the association analysis is performed on the inferred haplotype groups. If a haplotype is unevenly distributed between the case and control samples, this haplotype is labeled
... Show MorePermanent magnets of different intensities were used to investigate the effect of a magnetic field in the process of preventing deposits of calcium carbonate. The magnets were fixed on the water line from the tap outside. Then heating a sample of this water in flasks and measuring the amount of sediment in a manner weighted differences. These experiments comprise to the change of the velocity of water flow, which amounted to (0.5, 0.75, 1) m/sec through the magnetic fields that are of magnetic strength (2200, 6000, 9250, 11000) Gauss, and conduct measurements, tests and compare them with those obtained from the use of ordinary water.The results showed the effectiveness of magnetic treatment in reducing the rate of deposition of calcium carb
... Show MoreThis study was carried out to investigate the effects of magnetized water on accumulated infiltration depth. A test rig was designed and constructed for this purpose was installed at the water tests laboratory of the Department of Water Resources Engineering at the University of aghdad. The investigation was carried out by using two types of soil, different flow velocities throughout magnetizing device and different configuration of magnets over and under the water passage of the magnetizing device. The soils that were used in the experiments are clayey and sandy soils. Six different flow velocities throughout magnetizing device ranged between 0.29 to 1.19 cm/s and ten configurations of arranging the magnets over and under th
... Show MoreThis paper presents a new approach to discover the effect of depth water for underwater visible light communications (UVLC). The quality of the optical link was investigated with varying water depth under coastal water types. The performance of the UVLC with multiple input–multiple output (MIMO) techniques was examined in terms of bit error rate (BER) and data rate. The theoretical result explains that there is a good performance for UVLC system under coastal water.