Due to the popularity of radar, receivers often “hear” a great number of other transmitters in
addition to their own return merely in noise. The dealing with the problem of identifying and/or
separating a sum of tens of such pulse trains from a number of different sources are often received on
the one communication channel. It is then of interest to identify which pulses are from which source,
based on the assumption that the different sources have different characteristics. This search deals with a
graphical user interface (GUI) to generate the radar pulse in order to use the required radar signal in any
specified location.
Lead-free 0.88(Na0.5Bi0.5)TiO3–0.084(K0.5Bi0.5)TiO3–0.036BaTiO3 (BNT–BKT–BT) piezoelectric ceramics were prepared using the conventional mixed-oxide method with a sintering temperature range of 1120–1200 °C. The effect of the sintering temperature on the crystal structure, microstructure, and densification, as well as the dielectrics, piezoelectrics, and the pyroelectric properties of BNT–BKT–BT ceramics were investigated. Scanning electron microscopy and X-ray diffraction were used to study the microstructures of the sintered samples. The results showed that the increase in sintering temperature was very effective in improving both the density and electrical properties. However, the samples deteriorated when the sintering te
... Show MoreIn this work, InSe thin films were deposited on glass substrates by thermal evaporation technique with a deposit rate of (2.5∓0.2) nm/sec. The thickness of the films was around (300∓10) nm, and the thin films were annealed at (100, 200 and 300)°C. The structural, morphology, and optical properties of Indium selenide thin films were studied using X-ray diffraction, Scanning Electron Microscope and UV–Visible spectrometry respectively. X-ray diffraction analyses showed that the as deposited thin films have amorphous structures. At annealing temperature of 100°C and 200°C, the films show enhanced crystalline nature, but at 300°C the film shows a polycrystalline structure with Rhombohedral phas
(Received 21 May 2019, Revised 30 September 2019, Accepted 21 October 2019)ABSTRACT : The results of the current study showed that the liver of H. javanicus appeared as large lobulated organ dividedinto six distinct lobes, that filled the cranial region and little extended to the middle region of abdominal cavity. On the otherhand, liver of S. carolinensis laid against the diaphragm, occupied the cranial region of the abdominal cavity and consisted of fivelobes. The liver is surrounded with a thin capsule of dense regular collagenous connective tissue and few numbers of smoothmuscles fibers can be seen in the capsule that covered the squirrel liver. The liver parenchyma divided into a large number ofinterconnected hepatic lobules marked
... Show MoreStealthy intracellular bacterial pathogens are known to establish persistent and sometimes lifelong infections. Some of these pathogens also have a tropism for the reproductive system, thereby increasing the risk of reproductive disease and infertility. To date, the pathogenic mechanism involved remains poorly understood. Here, we demonstrate that
This study investigates the impact of incorporating carbon quantum dots (CQDs) into the SnO 2 electron transport layer (ETL) on the performance of all-inorganic CsPbBr 3 perovskite solar cells (PSCs). CQDs with abundant surface functional groups were synthesized hydrothermally and integrated into a low-temperature, solution-processed SnO 2 ETL at varying concentrations (0%, 2% and 4%). Comprehensive characterization revealed that the SnO 2 : CQDs composite films exhibited
... Show MoreA new, simple and sensitive method was used forevaluation of propranolol withphosphotungstic acidto prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on reaction between propranolol and phosphotungstic acid in an aqueous medium to obtain a yellow precipitate. Optimum parameters was studied to increase the sensitivity for developed method. A linear range for calibration graph was 0.007-13 mmol/L for cell A and 5-15 mmol/L for cell B, and LOD 207.4792 ng/160 µL and 1.2449 µg/160 µL respectively to cell A and cell B with correlation coefficient (r) 0.9988 for cell A, 0.9996 for cell B, RSD% was lower than 1%, (n=8) for the
... Show More