Due to the popularity of radar, receivers often “hear” a great number of other transmitters in
addition to their own return merely in noise. The dealing with the problem of identifying and/or
separating a sum of tens of such pulse trains from a number of different sources are often received on
the one communication channel. It is then of interest to identify which pulses are from which source,
based on the assumption that the different sources have different characteristics. This search deals with a
graphical user interface (GUI) to generate the radar pulse in order to use the required radar signal in any
specified location.
Films of silver oxide of different thickness have been prepared by the chemical spray paralysis. Transmission and absorption spectra have recorded in order to study the effect of increasing thickness on some optical parameter such as reflectance, refractive index , and dielectric constant in its two parts . This study reveals that all these paramters affect by increasing the thickness .
Long memory analysis is one of the most active areas in econometrics and time series where various methods have been introduced to identify and estimate the long memory parameter in partially integrated time series. One of the most common models used to represent time series that have a long memory is the ARFIMA (Auto Regressive Fractional Integration Moving Average Model) which diffs are a fractional number called the fractional parameter. To analyze and determine the ARFIMA model, the fractal parameter must be estimated. There are many methods for fractional parameter estimation. In this research, the estimation methods were divided into indirect methods, where the Hurst parameter is estimated fir
... Show MoreIn this paper, a new seven-parameter Mittag-Leffler function of a single com-plex variable is proposed as a generalization of the standard Mittag-Leffler function, certain generalizations of Mittag-Leffler function, hypergeometric function and confluent hypergeometric function. Certain essential analytic properties are mainly discussed, such as radius of convergence, order, type, differentiation, Mellin-Barnes integral representation and Euler transform in the complex plane. Its relation to Fox-Wright function and H-function is also developed.
Background: The use of electronic apex locators for working length determination eliminates many of the problems associated with the radiographic measurements (interference of anatomical structures, errors in projection such as elongation or shortening, and lack of three-dimensional representation). Its most important advantage over radiography is that it measures the length of the root canal to the apical constriction, not to the radiographic apex. The aim of this study was to assess the accuracy of a new fifth generation apex locator (Joypex 5) in recording the apical constriction and comparing it with a third generation apex locator (Root ZX) in vitro. Materials and method: Twenty four single-rooted sound human premolars, extracted for t
... Show MoreThe nuclear structure of 38Ar, 59Co, 124Sn, 146Nd, 153Eu and 203Tl target nuclei used in technology for nuclear batteries have been investigation, in order that, these nuclei are very interesting for radioisotope thermo-electric generator (RTG) space studies and for betavoltaic battery microelectronic systems. The single particle radial density distribution, the corresponding root mean square radii (rms), neutron skin thicknesses and binding energies have been investigated within the framework of Hartree-Fock Approximation with Skyrme interaction. The bremsstrahlung spectrums produced by absorption of beta particles in betavoltaic process and backscattered p
... Show MoreObjectives: With the advent of ongoing novel modalities toward the treatment of human epidermal growth factor receptor 2 (HER2)/NEU - positive malignancies, the serious side effects of chemoradiotherapy have been minimized. Hence, this study was conducted to identify the patterns of immunohistochemical expression of the promising therapeutic target (HER2/NEU) among Iraqi patients with medulloblastoma in an attempt to provide basic histological information’s that would help in future clinical researches.Materials and Methods: In this retrospective study, 42 formalin - fixed paraffin - embedded tissue blocks represent cases of surgically removed medulloblastomas were retrieved from the archived materials in a specialized surgical ho
... Show MoreThis paper constructs a new linear operator associated with a seven parameters Mittag-Leffler function using the convolution technique. In addition, it investigates some significant second-order differential subordination properties with considerable sandwich results concerning that operator.
A new Differential Evolution (ARDE) algorithm is introduced that automatically adapt a repository of DE strategies and parameters adaptation schemes of the mutation factor and the crossover rate to avoid the problems of stagnation and make DE responds to a wide range of function characteristics at different stages of the evolution. ARDE algorithm makes use of JADE strategy and the MDE_pBX parameters adaptive schemes as frameworks. Then a new adaptive procedure called adaptive repository (AR) has been developed to select the appropriate combinations of the JADE strategies and the parameter control schemes of the MDE_pBX to generate the next population based on their fitness values. Experimental results have been presented to confirm the reli
... Show MoreThe aim of the present research is to investigate the effecting of pH parameter on the feasibility of lead removal from simulated wastewater using an electrochemical system. Electrocoagulation method is one of electrochemical technology which is used widely to treat industrial wastewater. Parameters affecting this operation, such as initial metal concentration, applied current, stirrer speed, and contact time of electroprocessing were taken as 155ppm, 1.5 Ampere, 150 rpm, 60 minutes respectively. While pH of the simulated wastewater was in the range of 2 to 12 in the experiments. It was found from the results that pH is an important parameter affecting lead removal operation. The best value of pH parameter is appro
... Show More