Preferred Language
Articles
/
joe-287
Experimental Evaluation Use of Semifluidized Bed Adsorber for the Treatment of P-chlorophenol and O-cresol in Wastewater using Activated Carbon as Adsorbent
...Show More Authors

In the present work the performance of semifluidized bed adsorber was evaluated for removal of phenolic compound from wastewater using commercial activated carbon as adsorbent. P-chlorophenol (4-Chlorophenol) and o-cresol (2-methylphenol) was selected as a phenolic compound for that purpose. The phenols percent removal, in term of breakthrough curves were studied as affected by hydrodynamics limitations which include minimum and maximum semifluidization velocities and packed bed formation in the column by varying various parameters such as inlet liquid superficial velocity (from Uminsf to 8Uminsf m/s), and retaining grid (sometimes referred to as adsorbent loading) to initial static bed height ratio (from 3-4.5). Inlet phenols concentration (50-400 mg/l) and initial pH of the liquid solutions feed (from 4 to 10) were also studied. The experimental semifluidized adsorber unit was designed and constructed in Chem. Eng. labs at Al-Nahrain University (consisted of a QVF glass tube 2.54 cm inside diameter, and 70cm length). The results showed that the initial percent removal of phenolic compounds (P-chlorophenol and o-cresol) decrease with increasing the superficial liquid velocity while the time required reaching equilibrium state decreased. Also it slightly affected with the increase in the retaining grid height and the time required to reach the equilibrium value decreased.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue May 01 2018
Journal Name
Journal Of Physics: Conference Series
Evaluation of the Epoxy/Antimony Trioxide Nanocomposites as Flame Retardant
...Show More Authors

View Publication
Scopus (25)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2014
Journal Name
International Journal Of Medical Physics, Clinical Engineering And Radiation Oncology
The Use of Left Ventricular Myocardial Stiffness Index as a Predictor of Myocardial Performance in Patients with Systemic Hypertension
...Show More Authors

Our aim was to investigate the changes in the myocardium stiffness index for patients suffering from systemic hypertension, and to assess their left ventricular performance. We studied 263 hypertensive patients and 166 healthy subjects as a control group. By using conventional Doppler echocardiography, the following parameters were measured—Left ventricular end diastolic diameter, left ventricular end systolic diameter, transmitral early velocity, isovolumic relaxation time, and isovolumic contraction time. Tissue Doppler imaging (TDI) was used in the measurements of the early mitral annular velocity (Ea) and the diastolic stiffness was obtained by calculating the ratio E\Ea\LVIDd. Index myocardial performance (IMP) was calculated

... Show More
View Publication
Crossref (3)
Crossref
Publication Date
Sun Feb 25 2024
Journal Name
Iraqi Journal Of Agricultural Sciences
THE EFFICIENCY OF GUM-SILICA CMPOSITE FOR REMOVING OF WASTEWATER TURBIDITY
...Show More Authors

A novel mixed natural coagulant has been developed to remove sewage pollutants and heavy metals from Qanat- al- Jayesh by using low cost adsorbent natural materials. In these materials, significant interaction contains Arabic gum mixed with extracted silica from rice husk ash (natural coagulants) by the Batch device approach, using two variables, pH values ranging from 5-8 and contact times between 0.25-5 hrs. All wastewater samples were collected after treatment by adsorbents and examined for determination of residual heavy metal concentrations: Pb, Ni, Zn and Cu by atomic absorption spectroscopy (AAS), turbidity, pH, total dissolved salts (TDS), electrical conductivity (EC) and total salinity (TS). The results obtained indicate Th

... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Crossref
Publication Date
Sun Feb 25 2024
Journal Name
Iraqi Journal Of Agricultural Sciences
THE EFFICIENCY OF GUM-SILICA CMPOSITE FOR REMOVING OF WASTEWATER TURBIDITY
...Show More Authors

A novel mixed natural coagulant has been developed to remove sewage pollutants and heavy metals from Qanat- al- Jayesh by using low cost adsorbent natural materials. In these materials, significant interaction contains Arabic gum mixed with extracted silica from rice husk ash (natural coagulants) by the Batch device approach, using two variables, pH values ranging from 5-8 and contact times between 0.25-5 hrs. All wastewater samples were collected after treatment by adsorbents and examined for determination of residual heavy metal concentrations: Pb, Ni, Zn and Cu by atomic absorption spectroscopy (AAS), turbidity, pH, total dissolved salts (TDS), electrical conductivity (EC) and total salinity (TS). The results obtained indicate Th

... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Crossref
Publication Date
Sat Jun 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the effectiveness of using platelet rich fibrin (PRF) as a sole grafting material and membrane in augmentation of dehiscence and fenestration defects encountered during dental implant surgery
...Show More Authors

Background: Bone regeneration in dehiscence and fenestration defect can be improved with the use of platelet rich fibrin (PRF) that provides a scaffold for new bone regeneration. This study was conducted to assess the effectiveness of PRF as a graft material and membrane in dehiscence and fenestration defects. Materials and Methods: This prospective clinical study included patients who received dental implants that demonstrated peri-implant defects which were augmented using Leukocyte- PRF (L-PRF) or Advanced-PRF (A-PRF). Twenty four weeks postoperatively the defect resolution and the density of regenerated bone were assessed by CBCT and re-entry surgery. The assessment also included measurement of primary and secondary implant stability

... Show More
View Publication
Scopus (3)
Crossref (4)
Scopus Crossref
Publication Date
Sun Jan 22 2023
Journal Name
Baghdad Science Journal
Corrosion Inhibition of Medium Carbon Steel in the Acidic Medium Using Alcoholic and Aqueous Extract of Kujarat Tea Plant
...Show More Authors

This study deals with the corrosion inhibition of metal corrosion process of medium carbon steel using 1M HCl for kinetic studies and rate reaction determination. The weight loss method is applied to pieces of Medium carbon steel divided to Cubans with dimensions (0.4*2*2.4) cm , and use Tafel Extrapolation Method, the samples were polished using carbide silicon paper with dimensions of (180,200,400,600,800,1000). The samples were immersed in the alcoholic medium ethanol at a temperature 293K for 3hr. Natural inhibitor Kujarat Tea (Hibiscus sabdarriffa L.) is used which is extracted in aqueous and alcoholic medium, different concentrations (1000،2000, 3000) ppm have been used ; The best concentration found through the results is a

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
Corrosion Inhibition of Medium Carbon Steel in the Acidic Medium Using Alcoholic and Aqueous Extract of Kujarat Tea Plant
...Show More Authors

This study deals with the corrosion inhibition of metal corrosion process of medium carbon steel using 1M HCl for kinetic studies and rate reaction determination. The weight loss method is applied to pieces of Medium carbon steel divided to Cubans with dimensions (0.4*2*2.4) cm , and use Tafel Extrapolation Method, the samples were polished using carbide silicon paper with dimensions of (180,200,400,600,800,1000). The samples were immersed in the alcoholic medium ethanol at a temperature 293K for 3hr. Natural inhibitor Kujarat Tea (Hibiscus sabdarriffa L.) is used which is extracted in aqueous and alcoholic medium, different concentrations (1000،2000, 3000) ppm have been used ; The best concentration found through the results is a conce

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jan 04 2018
Journal Name
International Journal Of Applied Pharmaceutics
FORMULATION AND IN VITRO EVALUATION OF BROMOCRIPTINE MESYLATE AS FAST DISSOLVING ORAL FILM
...Show More Authors

Objective: The aim of this study was to formulate and in vitro evaluate fast dissolving oral film of practically insoluble bromocriptine mesylate to enhance its solubility and to improve its oral bioavailability by avoiding first pass effect as well as to produce an immediate release action of the drug from the film for an efficient management of diabetes mellitus type II in addition to an improvement of the patient compliance to this patient- friendly dosage form. Methods: The films were prepared by the solvent casting method using hydroxypropyl methylcellulose of grades (E3, E5, E15), polyvinyl alcohol (PVA), pectin and gelatin as film-forming polymers in addition to polyethene glycol 400 (PEG400), propylene glycol (PG) and glycerin were

... Show More
Scopus (31)
Scopus
Publication Date
Wed Jul 05 2017
Journal Name
Chemical Engineering Communications
Microwave-assisted preparation of mesoporous-activated carbon from coconut (<i>Cocos nucifera</i>) leaf by H<sub>3</sub>PO<sub>4</sub>activation for methylene blue adsorption
...Show More Authors

View Publication
Scopus (126)
Crossref (118)
Scopus Clarivate Crossref
Publication Date
Wed Dec 13 2017
Journal Name
Al-khwarizmi Engineering Journal
Experimental Investigations Performance for (VCC) Using 2-Way (PFCV) Type (2FRE)
...Show More Authors

In modern hydraulic control systems, the trend in hydraulic power applications is to improve efficiency and performance. “Proportional valve” is generally applied to pressure, flow and directional-control valves which continuously convert a variable input signal into a smooth and proportional hydraulic output signal. It creates a variable resistance (orifice) upstream and downstream of a hydraulic actuator, and is meter in/meter out circuit and hence pressure drop, and power losses are inevitable. If velocity (position) feedback is used, flow pattern control is possible. Without aforementioned flow pattern, control is very “loose” and relies on “visual” feed back by the operator. At this point, we should examine how this valv

... Show More
View Publication Preview PDF