Preferred Language
Articles
/
joe-274
Enhanced Chain-Cluster Based Mixed Routing Algorithm for Wireless Sensor Networks
...Show More Authors

Energy efficiency is a significant aspect in designing robust routing protocols for wireless sensor networks (WSNs). A reliable routing protocol has to be energy efficient and adaptive to the network size. To achieve high energy conservation and data aggregation, there are two major techniques, clusters and chains. In clustering technique, sensor networks are often divided into non-overlapping subsets called clusters. In chain technique, sensor nodes will be connected with the closest two neighbors, starting with the farthest node from the base station till the closest node to the base station. Each technique has its own advantages and disadvantages which motivate some researchers to come up with a hybrid routing algorithm that combines the full advantages of both cluster and chain techniques such as CCM (Chain-Cluster based Mixed routing). In this paper, introduce a routing algorithm relying on CCM algorithm called (Enhanced Chain-Cluster based Mixed routing) algorithm E-CCM. Simulation results show that E-CCM algorithm improves the performance of CCM algorithm in terms of three performance metrics which are: energy consumption, network lifetime, and (FND and LND). MATLAB program is used to develop and test the simulation process in a computer with the following specifications: windows 7 (32-operating system), core i5, RAM 4 GB, hard 512 GB.

 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Aug 21 2021
Journal Name
Electronics
An Efficient Distributed Elliptic Positioning for Underground Remote Sensing
...Show More Authors

Remote surveying of unknown bound geometries, such as the mapping of underground water supplies and tunnels, remains a challenging task. The obstacles and absorption in media make the long-distance telecommunication and localization process inefficient due to mobile sensors’ power limitations. This work develops a new short-range sequential localization approach to reduce the required amount of signal transmission power. The developed algorithm is based on a sequential localization process that can utilize a multitude of randomly distributed wireless sensors while only employing several anchors in the process. Time delay elliptic and frequency range techniques are employed in developing the proposed algebraic closed-form solution.

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Sep 12 2016
Journal Name
Revista Pesquisa Em Fisioterapia
YOGA AS A TREATMENT FOR MUSCULOSKELETAL DISCOMFORTS: A HYPOTHESIS
...Show More Authors

Introduction: Nowadays, the prevalence of Musculoskeletal Discomforts (MSD) is increasing in the world. As treatment, usually surgery or physiotherapyare recommended, but they are expensive and may cause side effects. Apracticalcourse of treatment without negative side effects and with permanent positive effects is lacking. Objective: To suggest a practical course of treatment, introduced by a licensed Yoga coach who is experienced in this field, and through thatto shed a light on yoga as treatment for MSD. The hypothesis is that yoga may decrease the pain among individuals with MSD. Methods: This hypothesis is presented based on the practical techniques used in Yoga including body relaxation and breathing awareness (2 minutes & 3 minutes r

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Nov 01 2013
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
Podophyllin (10%) Ointment: A New Therapeutic Modality for Psoriasis
...Show More Authors

KE Sharquie, AA Noaimi, WK Al-Janabi, Journal of Cosmetics, Dermatological Sciences and Applications, 2013

View Publication
Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance Study of Electrodialysis for Treatment Fuel Washing Wastewater
...Show More Authors

In this work, electrodialysis (ED) has been demonstrated to be appropriate technique for reducing the electrical conductivity of real wastewater from fuel washing unit, which has been previously treated by other electrochemical technology (electrocoagulation and electrooxidation).  A five cell electrodialysis stack, with an active membrane area of 60 cm2 per cell was employed. During a batch recirculation mode ED system, the effects of parameters such as electrical potential applied (6-18 V) and flow rate of streams (0.5-1.7 L/min.) on the performance of the total dissolved solids (TDS) separation and specific power consumption (SPC) were studied. The results indicate that the process of ED under potential (15 V) and flow

... Show More
View Publication Preview PDF
Publication Date
Fri Nov 05 2021
Journal Name
Semiconductor Science And Information Devices
Cladding Modified Fiber Bragg Grating for Copper Ions Detection
...Show More Authors

This paper reports a fiber Bragg grating (FBG) as a biosensor. The FBGs were etched using a chemical agent,namely,hydrofluoric acid (HF). This implies the removal of some part of the cladding layer. Consequently, the evanescent field propagating out of the core will be closer to the environment and become more sensitive to the change in the surrounding. The proposed FBG sensor was utilized to detect toxic heavy metal ions aqueous medium namely, copper ions (Cu2+). Two FBG sensors were etched with 20 and 40 μm diameters and fabricated. The sensors were studied towards Cu2+ with different concentrations using wavelength shift as a result of the interaction between the evanescent field and copper ions. The FBG sensors showed

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Fri Apr 01 2016
Journal Name
Journal Of Engineering
Estimation of Mass Transfer Coefficient for Copper Electrowinning Process
...Show More Authors

Mass transfer was examined at a stationary rectangular copper electrode (cathode) by using the reduction of cupric ions as the electrochemical reaction. The influence of electrolyte temperature (25, 45, and 65 oC), and cupric ions concentration (4, 8, and 12 mM) on mass transfer coefficient were investigated by using limiting current technique. The mass transfer coefficient and hence the Sherwood number was correlated as Sh =

 

View Publication Preview PDF
Publication Date
Tue Oct 02 2018
Journal Name
Iraqi Journal Of Physics
Synthesis and characterization of Au nanoparticles for nanomedicine application
...Show More Authors

Gold nanoparticles AuNPs have proven to be powerful tools in various nanomedicine applications, because of their photo-optical distinctiveness and biocompatibility. Noble metal gold nanoparticles was prepared by pulsed laser ablation method (1064-Nd: YAG with various Laser power from 200 to 800 mJ and 1 Hz frequency) in distil water. The process was characterized using UV-VIS absorption spectroscopy. Morphology and average size of nanoparticles were estimated using AFM and X-ray diffraction (XRD) analysis which show the nature of gold nanoparticles (AuNPs). Antibacterial activity of gold nanoparticles as a function of particles concentration against gram negative bacterium Escherichia coli and gram positive bacterial Staphylococcus aureu

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Interdisciplinary Mathematics
Enforcement for the groups SL(2,125) and SL(2,3125)
...Show More Authors

The group for the multiplication of closets is the set G|N of all closets of N in G, if G is a group and N is a normal subgroup of G. The term “G by N factor group” describes this set. In the quotient group G|N, N is the identity element. In this paper, we procure K(SL(2,125)) and K(SL(2,3125)) from the character table of rational representations for each group.

View Publication
Scopus (11)
Scopus Clarivate Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
(?m 10.6) Design study for Reserve of laser CO2
...Show More Authors

In this paper , the CO2 laser receiver system is designed and studied, with wavelength laser 10.6 ?m in room temperature , and to evaluate the performance and discussion it via the package of optical design (ZEMAX), from its output the Spot Diagram is measured through RMS ,and from the Ray fan plot , the aberrations is found which is the normal error for the best focus named (under corrected ) , the other output was the Geometric Encircled Energy in the spot diagram . and found that the radius of spot diagram at 80% (R80%) from the total energy ,and focal shift .The designed system have high efficiency and low cost .

View Publication Preview PDF
Crossref
Publication Date
Wed Jun 10 2009
Journal Name
Iraqi Journal Of Laser
A new achromatic glass for near infrared laser instruments
...Show More Authors

This research investigates new glasses which are best suitable for design of optical systems
working in the infrared region between 1.01 to 2.3μm. This work is extended to Oliva & Gennari
(1995,1998) research in which they found that the best known achromatic pairs are (BAF2-IRG2; SRF2-
IRG3; BAF2-IRG7; CAF2-IRGN6; BAF2-SF56A and BAF2-SF6). Schott will most probably stop the
production of these very little used and commercially uninteresting IRG glasses. In this work equally
good performances can be obtained by coupling BAF2, SRF2&CAF2 with standard glasses from Schott
or Ohara Company. The best new achromatic pairs found are (SRF2-S-TIH10; CAF2-S-LAL9; CAF2-SLAL13
and CAF2-S-BAH27). These new achromatic pai

... Show More
View Publication Preview PDF