The aim of research is to show the effect of Ferric Oxide (Fe2O3) on the electricity production and wastewater treatment, since 2.5% of Ferric Oxide (Fe2O3) (heated and non heated) nanoparticles has been used. Characterization of nanoparticles was done using X-ray Diffraction (XRD) and Scan Electron Microscopy (SEM). The influence of acidity was also studied on both wastewater treatmenton the Chemical Oxygen demand (COD) and Biological Oxygen Demand (BOD) and voltage output was studied. From the results, it was infused that the dosage of 0.025 g/l and an initial pH 7 were founded to be optimum for the effective degradation of effluents. The results concluded that the treatment of anaerobic sludge wastewater using Ferric Oxide (Fe2O3) in combination with microbialmfuel cell technology is an efficient method for the treatment of anaerobic sludge wastewater.
Gas compressibility factor or z-factor plays an important role in many engineering applications related to oil and gas exploration and production, such as gas production, gas metering, pipeline design, estimation of gas initially in place (GIIP), and ultimate recovery (UR) of gas from a reservoir. There are many z-factor correlations which are either derived from Equation of State or empirically based on certain observation through regression analysis. However, the results of the z-factor obtained from different correlations have high level of variance for the same gas sample under the same pressure and temperature. It is quite challenging to determine the most accurate correlation which provides accurate estimate for a range of pressures,
... Show MoreThis work investigates the impacts of eccentric-inclined load on ring footing performance resting on treated and untreated weak sandy soil, and due to the reduction in the footing carrying capacity due to the combinations of eccentrically-inclined load, the geogrid was used as reinforcement material. Ring radius ratio and reinforcement depth ratio parameters were investigated. Test outcomes showed that the carrying capacity of the footing decreases with the increment in the eccentric-inclined load and footing radius ratio. Furthermore, footing tilt and horizontal displacement increase with increasing the eccentricity and inclination angle, respectively. At the same time, the increment in the horizontal displacement due t
... Show MoreMangrove landscaping in the Segara Anakan Lagoon (SAL) is an adaptation pattern of mangrove ecosystems to live and grow in unstable areas. This research aimed to develop a mangrove landscape to mitigate the impacts of ocean waves, currents, and inundation due to climate change. The study was conducted in SAL and Cilacap Coast (CC) using the environmental properties and climate change data. The data obtained were analyzed using mapping and trendline analyses. The results showed that mangrove landscaping in Segara Anakan had four zones with Nypa frutican, Rhizophora styllosa, Aegiceras corniculatum, Rhizophora apiculata, Avicennia marina, Sonneratia alba identified as the best adaptation of mangrove species. Climate change give a high impa
... Show MoreThe study objective was to conduct Pharmacoeconomics study (cost-effective analysis) between infliximab reference (Remicade) and its biosimilar (Remsima) in patients with rheumatoid arthritis (RA) in Iraqi hospitals.
This is a retrospective multicenter pharmacoeconomic analysis conducted at two large teaching governmental hospitals in Baghdad, Iraq which provided infliximab to patients with RA. Data were collected from patient’s medical records and face-to-face interviews with the patients from December 2021 to April 2022.
The study included 57 patients with rheumatoid arthritis (RA). The patients were categorized into two groups according to the type of infliximab they received over 30 weeks: 27 patients received
... Show MoreThe primary goal of in-situ load testing is to evaluate the safety and performance of a structural system under particular loading conditions. Advancements in building techniques, analytical tools, and monitoring instruments are prompting the evaluation of the appropriate loading value, loading process, and examination criteria. The procedure for testing reinforced concrete (RC) structures on-site, as outlined in the ACI Building Code, involves conducting a 24-h load test and applying specific evaluation criteria. This article detailed a retrofitting project for an RC slab-beams system by utilizing carbon fiber-reinforced polymer (CFRP) sheets to strengthen the structure following a fire incident. The RC structure showed indicators of deter
... Show MoreBackground: Beta thalassemia major is an inherited disorder that may affect general and oral health.The purpose of this study was toassess the severity of dental caries in relation to oral cleanliness, mutans streptococciamong a group of boys with beta thalassemia majorin comparison with a control group. Materials and Methods: The study involved 30 boys with BTM aged 10-12 years compared to 30 healthy boys with the same age group. d1-4mfs and D1-4 MFS indices were applied (Muhlemann, 1976), the viable counts of mutans streptococci in stimulated saliva were also determined. Results: The entire thalassemic group was caries-active. For both dentitions, a higher dmfs/DMFS values were recorded for study compared to control group, difference was
... Show MoreActivated carbon prepared from date stones by chemical activation with ferric chloride (FAC) was used an adsorbent to remove phenolic compounds such as phenol (Ph) and p-nitro phenol (PNPh) from aqueous solutions. The influence of process variables represented by solution pH value (2-12), adsorbent to adsorbate weight ratio (0.2-1.8), and contact time (30-150 min) on removal percentage and adsorbed amount of Ph and PNPh onto FAC was studied. For PNPh adsorption,( 97.43 %) maximum removal percentage and (48.71 mg/g) adsorbed amount was achieved at (5) solution pH,( 1) adsorbent to adsorbate weight ratio, and (90 min) contact time. While for Ph adsorption, at (4) solution pH, (1.4) absorbent to adsorbate weight ratio, and (120 min) contact
... Show MoreThe present study aimed to determine the serum sex hormone levels among Benign Prostatic Hyperplasia (BPH) patients before and after 3 months of oral administration of 5-α reductase inhibitor(finasteride). Forty BPH patients and 40 healthy men from Amara city were involved in this study, their ages were between 40-59 year. They were all subjected to direct estimation of hormones by MinVidas method including Testosterone (T), Estradiol (E2), Follicle Stimulating Hormone (FSH), Luteinizing Hormone (LH), Prolactin (PRL), and Dihydrotestosterone (DHT) before and after 3 months of treatment with 5α-reductase inhibitor (finasteride) (the healthy individuals didn’t take finasteride).The results showed that T level was significantly lo
... Show More