Preferred Language
Articles
/
joe-2547
Bioremediation of Soil Contaminated with 2,4-D Herbicide Using Bioslurry Reactor
...Show More Authors

Ex-situ bioremediation of 2,4-D herbicide-contaminated soil was studied using a slurry bioreactor operate at aerobic conditions. The performance of the slurry bioreactor was tested for three types of soil (sand, sandy loam and clay) contaminated with different concentration of 2,4-D, 200,300and500mg/kg soil. Sewage sludge was used as an inexpensive source of microorganisms which is available in large quantities in wastewater treatment plants. The results show that all biodegradation experiments demonstrated a significant decreases in 2,4-D concentration in the tested soils. The degradation efficiency in the slurry bioreactor decreases as the initial concentration of 2,4-D in the soils increases.A 100 % removal was achieved at initial concentration of 200mg 2,4-D/kg of sandy soil after 12 days and 92 % at 500mg 2,4-D/kg sandy soil after 14 days.Clay soil represented minimum removal efficiency among the three soils, 82 % at initial concentration of 200mg 2,4-D/kg clay soil after 12 days and 72 % for 500mg 2,4-D/kg clay soil after
14 days. Abiotic conditions were performed to investigate the desorption efficiency of the contaminant from soil to liquid phase through the three soils. In abiotic reactor the results showed that the rate of desorption for sand and sandy loam soils were nearly the same, it varied between0.102-0.135 day-1 at different initial concentration of 2,4-D. While for clay soil the desorption rate varied between 0.042- 0.031 day-1 at different initial concentration of 2,4-D. The decrease in desorption rate in clay soil refers to the characteristic of clay soil, (fine texture, high organic matter and high cation exchange capacity compared with the other soils) that may retain the 2,4-D in the organic matter and the clay minerals.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Experimental and numerical study of the bulb's location effect on the behavior of under-reamed pile in expansive soil
...Show More Authors
Abstract<p>In this experimental and numerical analysis, three varieties of under-reamed piles comprising one bulb were used. The location of the bulb changes from pile to pile, as it is found at the bottom, center, and top of the pile, respectively. <italic>PLAXES 3D</italic> was used to conduct the research. In expansive soil, the under-reamed piles were 350 mm long, with the pile tip in dense sandy soil. The experiment was carried out in both saturated and unsaturated circumstances. The influence of the bulb location on the pile's bearing capacity for vertical and lateral loads, as well as the amount of swelling pressure and upward movement owing to swelling, was investigated. The re</p> ... Show More
Crossref (6)
Crossref
Publication Date
Wed Aug 28 2019
Journal Name
Journal Of Engineering
Predicting Wetting Patterns in Soil from a Single Subsurface Drip Irrigation System
...Show More Authors

Soil wetted pattern from a subsurface drip plays great importance in the design of subsurface drip irrigation (SDI) system for delivering the required water directly to the roots of the plant. An equation to estimate the dimensions of the wetted area in soil are taking into account water uptake by roots is simulated numerically using HYDRUS (2D/3D) software. In this paper, three soil textures namely loamy sand, sandy loam, and loam soil were used with three different types of crops tomato, pepper, and cucumber, respectively, and different values of drip discharge, drip depth, and initial soil moisture content were proposed. The soil wetting patterns were obtained at every thirty minutes for a total time of irrigation equ

... Show More
View Publication Preview PDF
Crossref (10)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Agrosystems, Geosciences &amp; Environment
Cover crop influence on soil water dynamics for a corn–soybean rotation
...Show More Authors
Abstract<p>Crop production is reduced by insufficient and/or excess soil water, which can significantly decrease plant growth and development. Therefore, conservation management practices such as cover crops (CCs) are used to optimize soil water dynamics, since CCs can conserve soil water. The objective of this study was to determine the effects of CCs on soil water dynamics on a corn (<italic>Zea mays</italic> L.)–soybean [<italic>Glycine max</italic> (L.) Merr.] rotation at three soil depths over 3 yr. The study was conducted at the Chariton County Cover Crop Soil Health Research and Demonstration Farm (CCSH) in Missouri. Initial CC establishment occurred in 2012. Volumetric soil water </p> ... Show More
View Publication
Scopus (19)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Sat Dec 10 2022
Journal Name
المجلة العراقية لعلوم التربة
ACTINOMYCETES GENERAL CHARACTERISTICS AND THEIR ROLE IN SOIL, PLANT, AND HUMAN *HEALTH
...Show More Authors

Actinomycetes are free, spore-forming, high (G+C) ratio (>55%) saprophytic microorganisms that are widely distributed in most soils, colonize plants, and are prevalent in water. This is frequently accompanied by the production of filament airborne mycelium. Actinomycetes are well-known microcolonies for creating antibiotics and other critical bioactive components that are beneficial to humans. Approximately 70% to 80% of commercially available medications and antiviral active compounds have been synthesized so far. Secondary metabolites produced by microbes have the potential to be used in a variety of sectors, including antimicrobial agents, enzyme technology, pigment manufacture, antitumor agents against cancer cells, and toxin pr

... Show More
Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Terramechanics
Interaction of a rigid beam resting on a strong granular layer overlying weak granular soil: Multi-methodological investigations
...Show More Authors

In the geotechnical and terramechanical engineering applications, precise understandings are yet to be established on the off-road structures interacting with complex soil profiles. Several theoretical and experimental approaches have been used to measure the ultimate bearing capacity of the layered soil, but with a significant level of differences depending on the failure mechanisms assumed. Furthermore, local displacement fields in layered soils are not yet studied well. Here, the bearing capacity of a dense sand layer overlying loose sand beneath a rigid beam is studied under the plain-strain condition. The study employs using digital particle image velocimetry (DPIV) and finite element method (FEM) simulations. In the FEM, an experiment

... Show More
View Publication
Scopus (13)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Numerical Simulation of Unsaturated Soil Water Flow from a Trickle Point System, Considering Evaporation and Root Water Uptake
...Show More Authors

This research was carried out to study the effect of plants on the wetted area for two soil types in Iraq and predict an equation to determine the wetted radius and depth for two different soil types cultivated with different types of plants, the wetting patterns for the soils were predicted at every thirty minute for a total irrigation time equal to 3 hr. Five defferent discharges of emitter and five initial volumetric soil moisture contents were used ranged between field capacity and wilting point were utilized to simulate the wetting patterns. The simulation of the water flow from a single point emitter was completed by utilized HYDRUS-2D/3D software, version 2.05. Two methods were used in developing equations to predict the domains o

... Show More
View Publication
Crossref
Publication Date
Wed Nov 28 2018
Journal Name
International Journal Of Engineering &amp; Technology
Using Polyurethane Coating of Concrete Pipes with Acid Attack Resistance in Sewer Lines
...Show More Authors

One of the most important challenges facing the designers of the sewerage system is the corrosion of sewers due to the influence of sewerage contaminates which lead to failure of the main lines of sewers. In this study, a reference mix of 1: 1.5: 3 was used and the 4% Flocrete PC200 by weight of cement was added to the same mixing ratio in the second mixture. Twenty-four samples were tested for each mixture, 12 of which were used to compression strength test in ages (7, 14 and 28) day and six samples were submerged after 28 days of wet treatment at (5 and 10) % concentrations of sulfuric acid. The other six samples were painted after 28 days of wet treatment with coating Polyurethane and after 24 hours were flooded with a concentrat

... Show More
View Publication
Crossref
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Mechanical Science And Technology
Optimization of a rectangular pin fin using elliptical perforations with different inclination angles
...Show More Authors

View Publication
Scopus (5)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sat Dec 30 2017
Journal Name
International Journal Of Heat And Technology
Optimization of a rectangular pin fin using rectangular perforations with different inclination angles
...Show More Authors

View Publication
Scopus (6)
Crossref (3)
Scopus Crossref
Publication Date
Mon May 01 2023
Journal Name
Journal Of Engineering
Experimental Evaluation of PV Panel Efficiency Using Evaporative Cooling Integrated with Water Spraying
...Show More Authors

In this work, an inventive photovoltaic evaporative cooling (PV/EC) hybrid system was constructed and experimentally investigated. The PV/EC hybrid system has the prosperous advantage of producing electrical energy and cooling the PV panel besides providing cooled-humid air. Two cooling techniques were utilized: backside evaporative cooling (case #1) and combined backside evaporative cooling with a front-side water spray technique (case #2). The water spraying on the front side of the PV panel is intermittent to minimize water and power consumption depending on the PV panel temperature. In addition, two pad thicknesses of 5 cm and 10 cm were investigated at three different water flow rates of 1, 2, and 3 lpm. In Case #1,

... Show More
View Publication Preview PDF
Crossref (8)
Crossref