The need for participants’ performance assessments in academia and industry has been a growing concern. It has attendance, among other metrics, is a key factor in engendering a holistic approach to decision-making. For institutions or organizations where managing people is an important yet challenging task, attendance tracking and management could be employed to improve this seemingly time-consuming process while keeping an accurate attendance record. The manual/quasi-analog approach of taking attendance in some institutions could be unreliable and inefficient, leading to inaccurate computation of attendance rates and data loss. This work, therefore, proposes a system that employs embedded technology and a biometric/ web-based application to enhance attendance management. The hardware encompasses the integration of an ESP8266 NodeMCU and the biometric AS608 fingerprint sensor interfaced with the database for which the front-end and back-end integration was through the React framework. The system uses a web application that displays the attendance results and scheduled course data from its database, provides feedback to lecturers on which student missed classes and calculates a student’s average attendance for the semester. By implementing this system, the accuracy of student attendance is expected to experience an appreciable improvement, eliminate proxy signing, provide a more secure alternative for attendance recording, curtail tardiness to classes, and ultimately improve student productivity on execution.
We have investigated the photoemission and electronic properties at the PTCDI molecules interface on TiO2 and ZnO semiconductor by means of charge transition. A simple donor acceptor scenario used to calculate the rate for electron transfer of delocalized electronics in a non-degenerately TiO2 and ZnO electrodes to redox localized acceptors in an electrolytic. The dependent of electronic transition rate on the potential at contact of PTCDI with TiO2 and ZnO semiconductors, it has been discussion using TiO2 and ZnO electrodes in aqueous solutions. The charge transfer rate is determining by the overlapping electronic coupling to the TiO2 and ZnO electrodes, the transition energy, potential and polarity media within the theoretical scenario of
... Show MoreE-learning seeks to create an interactive learning environment between the teacher and the learner through electronic media conveying in more than one direction, regardless of how the environment and its variables are identified. It also develops skills necessary to deal with technology in order to be able to take into account the individual differences between them and helps e-learning teacher and learner to achieve the goals set in advance and identify educational objectives in a clear manner. The research aims to identify e-learning in its benefits and management systems. It has three sections dealt with in the current research. Chapter II concentrates on the research Methodology, which consisted of three sections: The first s
... Show MoreBackground: A major difference between the treatment of the skin lesions and the odontogenic and non-odontogenic sinuses. We aimed to analyze a substantial number of consecutive causes in order to clinical suspicion in the differential diagnoses may be correctly weighted. Materials and methods: The material of this research consisted of 40 patients. A complete history is collected from the patients with the duration and the site of the sinus present, the patient was examined for factors of the fistulas and sinuses and its associations, and patient having any concomitant lesions, a medical consultation done for opinion and management. Clinical examination with facial fistulas and sinuses was mandatory to avoid any mistakes that may occur. A
... Show MoreReverse Phase High Performance Liquid Chromatography (RP-HPLC) was coupled with ultraviolet absorption sepectoscopy (UV) for separation and identification of Naphthalene, Acenaphthylene, Pyrene, Benz{a} anthracene and 1,3,2,4-Dibenzanthracene. RP-HPLC was performed on an ODS-C18 column (150×4.6 mm I.D) using acetonitrile–buffer phosphate as mobile phase. UV absorption spectra of the elutes was detected in 254 nm, and studying the chromatographic variables include organic modifier ratio, PH, column temperature and concentration of buffer to maximize resolution and minimize separation time. the results showed that using mobile phase( 80:20) v/v acetonitrile:0.01M phosphate buffer solution at PH 6 with flow rate 1ml/min and column te
... Show MorePseudomonas aeruginosa is the most common opportunistic pathogen causing morbidity and mortality in hospitalized patients due to its multiple resistance mechanisms. Therefore, as a therapeutic option becomes restricted, the search for a new agent is a preference. So P. aeruginosa is an extremely versatile Gram-negative bacterium capable of thriving in a broad spectrum of environments, and this performs main problems to workers in the field of health. One hundred and fifty samples were collected from different sources from Baghdad hospitals, divided into two main groups: clinical (100) specimens and (50) samples as an environmental, collected from October 2019 to the March 2020. All of these samples were cultured by specific and differential
... Show MoreAcute appendicitis is one of the commonest causes of acute abdomen. There is a wide discussion and controversy on the surgical and nonsurgical treatment of acute uncomplicated appendicitis. The aim of this study was to evaluate the efficacy and outcomes of the conservative management of selected cases of acute appendicitis with an antibiotic first plan.
This was a single hospital-based prospective study with a durat
A novel robust finite time disturbance observer (RFTDO) based on an independent output-finite time composite control (FTCC) scheme is proposed for an air conditioning-system temperature and humidity regulation. The variable air volume (VAV) of the system is represented by two first-order mathematical models for the temperature and humidity dynamics. In the temperature loop dynamics, a RFTDO temperature (RFTDO-T) and an FTCC temperature (FTCC-T) are designed to estimate and reject the lumped disturbances of the temperature subsystem. In the humidity loop, a robust output of the FTCC humidity (FTCC-H) and RFTDO humidity (RFTDO-H) are also designed to estimate and reject the lumped disturbances of the humidity subsystem. Based on Lyapunov theo
... Show More