Estimation of Mass Transfer Coefficient for Copper Electrowinning Process
...Show More Authors

Mass transfer was examined at a stationary rectangular copper electrode (cathode) by using the reduction of cupric ions as the electrochemical reaction. The influence of electrolyte temperature (25, 45, and 65 oC), and cupric ions concentration (4, 8, and 12 mM) on mass transfer coefficient were investigated by using limiting current technique. The mass transfer coefficient and hence the Sherwood number was correlated as Sh =

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Apr 10 2013
Journal Name
Journal Of Materials Science And Engineering
Energy Transfer of Rhodamine110-Oxazine1 Mixtures Encapsulated in Glass Like Silica Xerogel Matrices
...Show More Authors

Publication Date
Wed Mar 30 2011
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
PARAMETRIC STUDY OF NATURAL CONVECTIVE AND RADIATIVE HEAT TRANSFER IN INCLINED CYLINDRICAL ANNULI
...Show More Authors

The unsteady state laminar mixed convection and radiation through inclined
cylindrical annulus is investigated numerically. The two heat transfer mechanisms of
convection and radiation are treated independently and simultaneously. The outer
cylinder was kept at a constant temperature while the inner cylinder was heated with
constant heat flux. The study involved numerical solution of the governing equations
which are continuity, momentum and energy equations using finite difference method
(FDM), where the body fitted coordinate system (BFC) was used to generate the grid
mesh for computational plane. A computer program (Fortran 90) was built to calculate
the bulk Nusselt number (Nub) after reaching steady state con

... Show More
View Publication Preview PDF
Publication Date
Thu May 01 2025
Journal Name
Journal Of Industrial And Engineering Chemistry
An innovative combination of anodic oxidation using Cu/SnO2–Sb2O5 rotating cylinder anode with TiO2 photocatalytic process for treating hospital wastewater
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Chemical Engineering And Processing - Process Intensification
Optimization of a combined electrocoagulation-electro-oxidation process for the treatment of Al-Basra Majnoon Oil field wastewater: Adopting a new strategy
...Show More Authors

View Publication
Scopus (44)
Crossref (35)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Chemical Engineering And Processing - Process Intensification
Optimization of a combined electrocoagulation-electro-oxidation process for the treatment of Al-Basra Majnoon Oil field wastewater: Adopting a new strategy
...Show More Authors

The performance of a synergistic combination of electrocoagulation (EC) and electro-oxidation (EO) for oilfield wastewater treatment has been studied. The effect of operative variables such as current density, pH, and electrolyte concentration on the reduction of chemical oxygen demand (COD) was studied and optimized based on Response Surface Methodology (RSM). The results showed that the current density had the highest impact on the COD removal with a contribution of 64.07% while pH, NaCl addition and other interactions affects account for only 34.67%. The optimized operating parameters were a current density of 26.77 mA/cm2 and a pH of 7.6 with no addition of NaCl which results in a COD removal efficiency of 93.43% and a specific energy c

... Show More
View Publication Preview PDF
Scopus (44)
Crossref (35)
Scopus Clarivate Crossref
Publication Date
Wed Dec 27 2017
Journal Name
Al-khwarizmi Engineering Journal
The Effect of Restriction Shape On Laminar Natural Convection Heat Transfer In A Vertical Circular Tube
...Show More Authors

Natural convection heat transfer is experimentally investigated for laminar air flow in a vertical circular tube by using the boundary condition of constant wall heat flux in the ranges of (RaL) from (1.1*109) to (4.7*109). The experimental set-up was designed for determining the effect of different types of restrictions placed at entry of heated tube in bottom position, on the surface temperature distribution and on the local and average heat transfer coefficients. The apparatus was made with an electrically heated cylinder of a length (900mm) and diameter (30mm). The entry restrictions were included a circular tube of same diameter as the heated cylinder but with lengths of (60cm, 120cm), sharp-edge and

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
LEAD Removal from Industrial Wastewater by Electrocoagulation process
...Show More Authors

This investigation was carried out to study the treatment and recycling of wastewater in the Battery industry for an effluent containing lead ion. The reuse of such effluent can only be made possible by appropriate treatment method such as electro coagulation.
The electrochemical process, which uses a cell comprised aluminum electrode as anode and stainless steel electrode as cathode was applied to simulated wastewater containing lead ion in concentration 30 – 120 mg/l, at different operational conditions such as current density 0.4-1.2 mA/cm2, pH 6 -10 , and time 10 - 180 minute.
The results showed that the best operating conditions for complete lead removal (100%) at maximum concentration 120 mg/l was found to be 1.2 mA/cm2 cur

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Global Pharma Technology
Estimation of Some Trace Elements and Antioxidant Status in Breast Cancer Patients Undergoing Radiotherapy
...Show More Authors

Breast cancer (BC) is the most prevalent tract cancer in the world, including Iraq. The classified breast tumors to benign, malignant, and radiotherapy. Cancer treatment depends on certain stages such as mastectomy then chemotherapy alone or with radiation therapy or endocrine therapy according to the prognostic features obtained from the pathology report. The present study included 100 females. The women were split into two groups, control group that consisted of 50 apparently healthy females and 50 patients with BC group who undergo the radiotherapy. The current study highlighted on some of the anthropometric measurements, including the oxidative stress index malondialdehyde (MDA), the concentrations of total antioxidant capacity (TAC), s

... Show More
Preview PDF
Publication Date
Sat Oct 06 2018
Journal Name
Journal Of Global Pharma Technology
Estimation of Some Trace Elements and Antioxidant Status in Breast Cancer Patients Undergoing Radiotherapy
...Show More Authors

Breast cancer (BC) is the most prevalent tract cancer in the world, including Iraq. The classified breast tumors to benign, malignant, and radiotherapy. Cancer treatment depends on certain stages such as mastectomy then chemotherapy alone or with radiation therapy or endocrine therapy according to the prognostic features obtained from the pathology report. The present study included 100 females. The women were split into two groups, control group that consisted of 50 apparently healthy females and 50 patients with BC group who undergo the radiotherapy. The current study highlighted on some of the anthropometric measurements, including the oxidative stress index malondialdehyde (MDA), the concentrations of total antioxidant capacity (TAC), s

... Show More
Preview PDF
Scopus (2)
Scopus
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Engineering
Internal Convective Heat Transfer Effect on Iraqi Building Construction Cooling Load
...Show More Authors

This work involves the calculation of the cooling load in Iraqi building constructions taking in account the effect of the convective heat transfer inside the buildings. ASHRAE assumptions are compared with the Fisher and Pedersen model of estimation of internal convective heat transfer coefficient when the high rate of ventilation from ceiling inlet configuration is used. Theoretical calculation of cooling load using the Radiant Time Series Method (RTSM) is implemented on the actual tested spaces. Also the theoretical calculated cooling loads are experimentally compared by measuring the cooling load in these tested spaces. The comparison appears that using the modified Fisher and Pedersen model when large ventilation ra