Preferred Language
Articles
/
joe-2395
Manufacturing and Study the performance of Selective Surfaces that used in flat plate Solar Collectors
...Show More Authors

In this research an experimental study has done for testing the thermal performance of selective surfaces used in solar collectors for substrate of iron, galvanized iron and aluminum which are commercially available. The coating process for the samples has done in two ways, the electroplating and the chemical spray pyrolysis. The results of the thermal performance test of these samples are comparing with the thermal performance of a sample without paint and other paint with black paint without shines commercially available. For the electroplated samples, the performance study has done for different immersion time in plating bath, the
distance between electrical poles, the current density, and area ratio of the sample plated area to the nickel pole face area. The chemical sprayed pyrolysis samples, study has done for different coating times, atomizing gas pressures, distance between the aperture of atomizer and the sample and the paint mass flow rate. The results showed that the best performance of the iron's
samples is the sample which is coated with two layers. The first layer is of zinc done by electroplating where the time of plating is (2 min.) and the second layer is of black nickel done by electroplating, where the time is (20 min.), the distance between the poles is (6 cm), the current density is (0.15 A/dm2 ) and area ratio of the sample plated area to the nickel pole face area is equal to (1). The percentage of the increasing in heat storage of electroplating sample to galvanized iron sample without paint at the beginning of testing the performance of samples and at the end were (58.23%& 44.97%) respectively. For aluminum samples, the best performance was regarded for two samples electroplating sample and chemical spray pyrolysis sample. The best electroplating sample was coated with a layer of black nickel where the time of plating is (20 min.), the distance between the poles is (6 cm), the current density is (0.15 A/dm2) and area ratio of the sample plated area to the nickel pole face area is equal to (1). While the best chemical spray pyrolysis sample has been coated with a layer of black nickel where the time of plating is (16 sec.) and the distance between the aperture of the reservoir and the surface of the sample is (27 cm), the amount of flow is (4.8 ml / min.), the atomizing gas pressure is (1 bar) and temperature of the sample surface is (290 0C).

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
World Journal Of Dentistry
In vitro Remineralization of Caries-affected Dentin after Selective Carious Tissue Removal
...Show More Authors

View Publication Preview PDF
Scopus (11)
Scopus
Publication Date
Tue Sep 19 2017
Journal Name
Al-academy
Technology manufacturing Ghazi oven and sessile cost of production of ceramic
...Show More Authors

The ceramic work of the business that was stationed with the history of its evolution of man on earth, and this gives him a linking formula and the reality of life, including asking as inherited civilized . Operation creativity over several stages and developments have helped in the formation of human hands, including a reflection on productions are large and diverse.

To search for new horizons in ceramic art began to form new technologies outside the traditional frameworks ,devoted  technical and scientific expertise and access to an advanced stage in porcelain from technical and aesthetic point of view the field, shall be deemed to contemporary ceramic civilized idea of ​​Modernism from the ceramic work can in no way b

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 27 2020
Journal Name
Journal Of Materials Science: Materials In Electronics
Areca catechu extracted natural new sensitizer for dye-sensitized solar cell: performance evaluation
...Show More Authors

View Publication
Scopus (44)
Crossref (34)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Engineering And Applied Sciences
Effect of silver doping for performance of CdS solar cell prepared by thermal vacuum evaporation
...Show More Authors

Publication Date
Wed Dec 01 2021
Journal Name
Iraqi Journal Of Physics
Effect of Deposit Au thin Layer Between Layers of Perovskite Solar Cell on Cell's Performance
...Show More Authors

The present work aims to fabricate n-i-p forward perovskite solar cell (PSC) withئ structure (FTO/ compact TiO2/ compact TiO2/ MAPbI3 Perovskite/ hole transport layer/ Au). P3HT, CuI and Spiro-OMeTAD were used as hole transport layers. A nano film of 25 nm gold layer was deposited once between the electron transport layer and the perovskite layer, then between the hole transport layer and the perovskite layer. The performance of the forward-perovskite solar cell was studied. Also, the role of each electron transport layer and the hole transport layer in the perovskite solar cell was presented. The structural, morphological and electrical properties were studied with X-ray diffractometer, field emission s

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Thu May 02 2019
Journal Name
Oral And Maxillofacial Surgery
Reconstruction plate-related complications in mandibular continuity defects
...Show More Authors

Purpose The purpose of this study was to evaluate the complications associated with the use of reconstruction plates with or without non-vascularized bone graft in reconstruction of mandibular segmental defects caused by trauma and tumor resection and to analyze various factors that are associated with the development of complications. Methods A retrospective observational study was conducted, and the investigated variables included the age and gender of the patients, etiology of the defect, the site of the defect, the size of the defect, whether bone graft was used or not, type of plate used, and whether the reconstruction was immediate or delayed. The outcome variables were the postoperative complications and the success rate. Results Fif

... Show More
View Publication
Scopus (19)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Wed Dec 11 2019
Journal Name
Journal Of The College Of Education For Women
The Impact of the Selective Model on the Acquisition of Kurdish Grammar Concepts among Female Students in the Eighth Grade
...Show More Authors

This research aims to identify the impact of the selective model in acquiring the concepts of Kurdish grammar among female students in the eighth grade, and to achieve the goal of research, the researcher selected the experimental design with partial control  and dimensional testing; the sample includes basic schools in the Chim district of Chamal/ Sulaymaniyah and randomly selected the basic school (Maha Bad) to be the field of application of the experiment and the random drawing method was chosen: two out of three sections and the number of students of the two sections is (75) students; section (C) represents the experimental group that studied the rules according to the selective model and its number is (37) students, while secti

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2013
Journal Name
Innovative Systems Design And Engineering
Water And Alcohol Extraction Of Thyme Plant (Thymus Vulgaris) And Activity Study Against Bacteria, Tumors And Used As Anti-Oxidant In Margarine Manufacture
...Show More Authors

Isolation had been done for active substances from Thyme plant (Thymus Vulgaris) such as volatile oils, Saponins and Tannins. The percentage in form was (21.1%),(59.2%),( 9.7%) respectively. Also a study of anti-bacterial activity of extracts from Thyme using two types of pathogenic bacteria Escherichia Coli and aurous Staphylococcus showed the ability of inhibition for all different extracts by vary inhibition diameters for different active substances, concentrations and bacteria. One type of cancer cellular line used to study the effect of Thyme extracts on the growth of cells in the laboratory and thus know the specifications of extracts as anti-tumor, (L20B) cell line have been used which is mice Transformed cell Line. The possibility o

... Show More
Preview PDF
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Flotation Method for Selective Separation of Lead and Zinc from Simulated Wastewater
...Show More Authors

In this paper flotation method experiments were performed to investigate the removal of lead and zinc. Various parameters such as pH, air flow rate, collector concentrations, collector type and initial metal concentrations were tested in a bubble column of 6 cm inside diameter. High recoveries of the two metals have been obtained by applying the foam flotation process, and at relatively short time 45 minutes . The results show that the best removal of lead about 95% was achieved at pH value of 8 and the best removal of zinc about 93% was achieved
at pH value of 10 by using 100 mg/l of Sodium dodecylsulfate (SDS) as a collector and 1% ethanol as a frother. The results show that the removal efficiency increased with increasing initial m

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 28 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Polymeric Membrane Sensors for the Selective Determination of Metoclopramide Hydrochloride and their Applications to Pharmaceutical Analysis
...Show More Authors

Metoclopramide (MCP) ion selective electrodes based on metoclopramide-phosphotungstic acid (MCP-PT) ion pair complex in PVC matrix membrane were constructed. The plasticizers used were tri-butyl phosphate (TBP), di-octyl phenyl phosphonate (DOPP), di-butyl phthalate (DBPH), di-octyl phthalate (DOP), di-butyl phosphate (DBP), bis 2-ethyl hexyl phosphate (BEHP). The sensors based on TBP, DOPP, DBPH and DOP display a fast, stable and linear response with slopes 59.9, 57.7, 57.4, 55.3 mV/decade respectively at pH ranged 2-6. The linear concentration range between 1.0×10-5 – 1.0×10-2 M with detection limit 3.0×10-6 and 4.0×10-6 M for electrodes using TBP, DOPP and DBPH while e

... Show More
View Publication Preview PDF
Crossref (1)
Crossref