A load flow program is developed using MATLAB and based on the Newton–Raphson method,which shows very fast and efficient rate of convergence as well as computationally the proposed method is very efficient and it requires less computer memory through the use of sparsing method and other methods in programming to accelerate the run speed to be near the real time.
The designed program computes the voltage magnitudes and phase angles at each bus of the network under steady–state operating conditions. It also computes the power flow and power losses for all equipment, including transformers and transmission lines taking into consideration the effects of off–nominal, tap and phase shift transformers, generators, shunt capacitors, shunt inductors, line reactors and bus reactors. Thus, overloaded transformers and transmission lines are identified, and remedial measure can be designed and implemented. It also provides the ability of tie lines, area splitting, and contingency analysis.
Any generator station(s) or busbar(s) that exceeds the specified operation limits will be automatically checked and flagged and then the program will automatically suggest the best solution to the problem. It also automatically checks whether the system is sub divided into sub areas or not. If yes, it will find the solution for each area separately. A complete report about the results and the state of the system (the violated generators, busbars, and transmission lines, the required modifications to overcome the violations, the names of the areas splitted,…) will be displayed in working window as well as generating a text file containing all details .
It is important to mention that this program is used by the national control center of the Ministry of Electricity and its efficiency was tested through applying the data of the two major Iraqi networks (400kV and 132kV), the program shows very accurate results and provides efficient notes about the status of the networks
Background: Hyperthyroidism occurs due to over production of thyroid hormones, one types of hyperthyroidism was Graves, disease. Hyperthyroidism is characterized by high level of serum thyroxin, triiodothyronine and low level of thyroid stimulated hormones. Material and Methods: fifty two hyperthyroid patients, thirty patients under treatment with carbimazole and other twenty two patients under treatment with radioactive iodine, and sixty healthy control group. The average salivary flow rate was calculated as ml/5mint.The concentration of calcium, potassium, and total protein were determined in the salivary supernatant sample. This is done through different biochemical tests. Determination of salivary IgA is done by ELIZA. Results: The most
... Show MoreComparative Analysis of Economic Policy Stability between Monarchical and Republican Systems: A Theoretical Fundamental Research
This study introduces a highly sensitive trapezium-shaped PCF based on an SPR refractometric sensor with unique design features. The structure of a sensor was designed and analyzed using COMSOL Multiphysics v5.6 based on Finite Element Method (FEM) with a focus on investigating the influence of various geometric parameters on its performance. The two channels were coated with a metallic gold layer to provide chemical stability, and a thin layer of TiO₂ improved the gold's adhesion to the fiber. The findings indicate that the proposed sensor achieves maximum amplitude and wavelength sensitivities of 1,779 RIU⁻¹ and 30,500 nm/RIU, respectively, with corresponding resolutions of 3.2
In solar-thermal adsorption/desorption processes, it is not always possible to preserve equal operating times for the adsorption/desorption modes due to the fluctuating supply nature of the source which largely affects the system’s operating conditions. This paper seeks to examine the impact of adopting unequal adsorption/desorption times on the entire cooling performance of solar adsorption systems. A cooling system with silica gel–water as adsorbent-adsorbate pair has been built and tested under the climatic condition of Iraq. A mathematical model has been established to predict the system performance, and the results are successfully validated via the experimental findings. The results show that, the system can be operational
... Show MoreThis paper presents a nonlinear finite element modeling and analysis of steel fiber reinforced concrete (SFRC) deep beams with and without openings in web subjected to two- point loading. In this study, the beams were modeled using ANSYS nonlinear finite element
software. The percentage of steel fiber was varied from 0 to 1.0%.The influence of fiber content in the concrete deep beams has been studied by measuring the deflection of the deep beams at mid- span and marking the cracking patterns, compute the failure loads for each deep beam, and also study the shearing and first principal stresses for the deep beams with and without openings and with different steel fiber ratios. The above study indicates that the location of openings an
A time series analysis can help to observe the behavior of the system and specify the system faults. In addition, it also helps to explain the various energy flows in the system and further aid in reducing the thermodynamic losses. The intelligent supervisory LabVIEW software can monitor the incoming data from the system by using Arduino microcontroller and calculates the important parameters. Energy, exergy, and anergy analysis present in this paper to investigate the system performance as well as its components. To accomplish this, a 4-ton vertical split air conditioner based on vapor compression refrigeration cycle charged with refrigerant R-22 was modified for experimental analysis. The results showed that during 540
... Show More
The heterogeneity nature of carbonate reservoirs shows sever scattering of the data, therefore, one has to be cautious in using the permeability- porosity correlation for calculating permeability unless a good correlation coefficient is available. In addition, a permeability- porosity correlation technique is not enough by itself since simulation studies also require more accurate tools for reservoir description and diagnosis of flow and non-flow units.
Evaluation of reservoir characterization was conducted by this paper for Mishrif Formation in south Iraqi oil field (heterogeneous carbonate reservoir), namely the permeability-porosity correlation, the hydraulic units (HU’s) an
... Show MoreIn this paper we used frequentist and Bayesian approaches for the linear regression model to predict future observations for unemployment rates in Iraq. Parameters are estimated using the ordinary least squares method and for the Bayesian approach using the Markov Chain Monte Carlo (MCMC) method. Calculations are done using the R program. The analysis showed that the linear regression model using the Bayesian approach is better and can be used as an alternative to the frequentist approach. Two criteria, the root mean square error (RMSE) and the median absolute deviation (MAD) were used to compare the performance of the estimates. The results obtained showed that the unemployment rates will continue to increase in the next two decade
... Show MoreIraqi EFL teachers face problems in teaching “English for Iraq Series” for primary public school pupils. In this paper, the researchers are going to identify the main problems faced by our teachers and try to find solutions to these problems. To achieve the aim of the study, list of questions asked and from teachers’ responses, the researchers have got an idea about the main problems which are related to textbook material, parents, learners, environment and technology. Therefore, the researchers adapted a questionnaire to achieve the purpose of the study with some changes and modifications. This questionnaire with five point scale (strongly agree, agree, undecided, disagree, strongly disagree). To achieve face validity, the
... Show MoreThe heterogeneity nature of carbonate reservoirs shows sever scattering of the data, therefore, one has to be cautious in using the permeability- porosity correlation for calculating permeability unless a good correlation coefficient is available. In addition, a permeability- porosity correlation technique is not enough by itself since simulation studies also require more accurate tools for reservoir description and diagnosis of flow and non-flow units. Evaluation of reservoir characterization was conducted by this paper for Mishrif Formation in south Iraqi oil field (heterogeneous carbonate reservoir), namely the permeability-porosity correlation, the hydraulic units (HU’s) and global hydraulic elements (GHE
... Show More