Preferred Language
Articles
/
joe-2254
Theoretical Study of the Effect of Permeability Tensor upon Drainage of Soils
...Show More Authors

the influence of permeability tensor upon drainage of anisotropic soils under ponded water and steady recharge (rainfall) is theoretically investigated. Tensorial permeability has led to the formulation of mixed type partial differential equations. Since there is no analytical solution to this problem, the formulation is therefore solved numerically by the method of finite elements. The finite element formulation is implemented into a computer model which can be applied to any problem of seepage under steady state
conditions. Two different example problems representing two different flow conditions under full anisotropy have been studied. Results of the model for the isotropic case were checked against exact mathematical solutions derived analytically for isotropic soils and found to be accurate which indicates that using this model for anisotropic soils is safe and sound

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Nov 21 2019
Journal Name
Journal Of Engineering
Comparative Permeability Estimation Method and Identification of Rock Types using Cluster Analysis from Well Logs and Core Analysis Data in Tertiary Carbonate Reservoir-Khabaz Oil Field
...Show More Authors

Characterization of the heterogonous reservoir is complex representation and evaluation of petrophysical properties and application of the relationships between porosity-permeability within the framework of hydraulic flow units is used to estimate permeability in un-cored wells. Techniques of flow unit or hydraulic flow unit (HFU) divided the reservoir into zones laterally and vertically which can be managed and control fluid flow within flow unit and considerably is entirely different with other flow units through reservoir. Each flow unit can be distinguished by applying the relationships of flow zone indicator (FZI) method. Supporting the relationship between porosity and permeability by using flow zone indictor is ca

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jun 14 2017
Journal Name
Iraq Journal Of Agricultural Research
STUDY THE EFFECT OF THE TYPE AND PERIOD OF MUTALISTIC WITH ARBUSCULAR MYCORRHIZA AND SOIL FERTILITY IN THE GROWTH OF TOMATO PLANT
...Show More Authors

The current study was conducted to evaluate the effect a mixture of threespecies of arbuscular mycorrhizal fungi (Glomus etunicatum, G. leptotichum andRhizophagus intraradices) double and triple mixture and organic matter by usingplastic pots in the greenhouse at some mycorrhiza and physiological limitationscharacteristics in tomato plant after four and eight weeks of cultivation. Theresults of the determinants mycorrhiza significant increase the percentage ofmycorrhizal frequency F% dry weight of roots mycorrhiza (g.plant-1) andorganic matter in all mycorrhiza single, double and triple mixture after four andeight weeks cultivation treatments. The highest percentage of mycorrhizalfrequency and increase the dry weight of the root in the trea

... Show More
Publication Date
Wed Mar 01 2023
Journal Name
Iraqi Journal Of Physics
Theoretical Computation of Electron Density in Laser-Induced Carbon Plasma using Anisimov Model
...Show More Authors

In this work, electron number density calculated using Matlab program code with the writing algorithm of the program. Electron density was calculated using Anisimov model in a vacuum environment. The effect of spatial coordinates on the electron density was investigated in this study. It was found that the Z axis distance direction affects the electron number density (ne). There are many processes such as excitation; ionization and recombination within the plasma that possible affect the density of electrons. The results show that as Z axis distance increases electron number density decreases because of the recombination of electrons and ions at large distances from the target and the loss of thermal energy of the electrons in high distance

... Show More
Publication Date
Fri Mar 15 2019
Journal Name
Al-khwarizmi Engineering Journal
Theoretical Prediction of Optimum Chilled Water Distribution Configuration in Air Conditioning Terminal Unit
...Show More Authors

 The distribution of chilled water flow rate in terminal unit is a major factor used to evaluate the performance of central air conditioning unit. In this work, a theoretical chilled water distribution in the terminal units has been studied to predict the optimum heat performance of terminal unit. The central Air-conditioning unit model consists of cooling/ heating coil (three units), chilled water source (chiller), three-way and two-way valve with bypass, piping network, and pump. The term of optimization in terminal unit ingredient has two categories, the first is the uniform of the water flow rate representing in statically permanents standard deviation (minimum value) and the second category is the maximum heat transfer rate fro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Theoretical Studies of Sum Optical Properties for InAs (001) by Surface Differential Reflectivity
...Show More Authors

The real and imaginary part of complex dielectric constant for InAs(001) by adsorption of oxsagen atoms has been calculated, using numerical analysis method (non-linear least square fitting). As a result a mathematical model built-up and the final result show a fairly good agreement with other genuine published works.

View Publication Preview PDF
Crossref
Publication Date
Mon Jul 10 2023
Journal Name
Journal Of Engineering
Theoretical Evaluation of Solar Assisted Desiccant Cooling System for a Small Meeting-Hall
...Show More Authors

The performance of a solar assisted desiccant cooling system for a meeting-hall located in the College of Engineering/University of Baghdad was evaluated theoretically. The system was composed of four components; a solar air heater, a desiccant dehumidifier, a heat exchanger and an evaporative cooler. A computer simulation was developed by using MATLAB to assess the effect of various design and operating conditions on the performance of the system and its components. The actual weather data on recommended days were used to assess the load variation and the system performance during those days. The radiant time series method (RTS) was used to evaluate the hourly variation of the cooling load. Four operation modes were employed for perform

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Iraqi Journal Of Physics
Theoretical Computation of Electron Density in Laser-Induced Carbon Plasma using Anisimov Model
...Show More Authors

In this work, electron number density calculated using Matlab program code with the writing algorithm of the program. Electron density was calculated using Anisimov model in a vacuum environment. The effect of spatial coordinates on the electron density was investigated in this study. It was found that the Z axis distance direction affects the electron number density (ne). There are many processes such as excitation; ionization and recombination within the plasma that possible affect the density of electrons. The results show that as Z axis distance increases electron number density decreases because of the recombination of electrons and ions at large distances from the target and the loss of thermal energy of the electrons in

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Civil Engineering Journal
Calibration of a New Concrete Damage Plasticity Theoretical Model Based on Experimental Parameters
...Show More Authors

The introduction of concrete damage plasticity material models has significantly improved the accuracy with which the concrete structural elements can be predicted in terms of their structural response. Research into this method's accuracy in analyzing complex concrete forms has been limited. A damage model combined with a plasticity model, based on continuum damage mechanics, is recommended for effectively predicting and simulating concrete behaviour. The damage parameters, such as compressive and tensile damages, can be defined to simulate concrete behavior in a damaged-plasticity model accurately. This research aims to propose an analytical model for assessing concrete compressive damage based on stiffness deterioration. The prop

... Show More
Scopus (35)
Crossref (32)
Scopus Clarivate Crossref
Publication Date
Thu May 31 2012
Journal Name
Al-khwarizmi Engineering Journal
An Experimental Study on the Effect of Shape and Location of Vortex Generators Ahead of a Heat Exchanger
...Show More Authors

An experimental study is carried out on the effect of vortex generators (Circular and square) on the flow and heat transfer at variable locations at (X = 0.5, 1.5, 2.5 cm) ahead of a heat exchanger with Reynolds number ranging from 62000< Re < 125000 and heat flux from 3000 ≤ q ≤ 8000 W/m2 .

In the experimental investigation, an apparatus is set up to measure the velocity and temperatures around the heat exchanger.                     

The results show that there is an effect for using vortex generators on heat transfer. Also, heat transfer depends on the shape and location. The circular is found t

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 25 2017
Journal Name
Biomedical And Pharmacology Journal
Comparative Study of the Effect of Incorporating SiO2 Nano-Particles on Properties of Poly methyl Methacrylate Denture Bases
...Show More Authors

View Publication
Crossref (26)
Crossref