The heat and mass transfer coefficients of the indirect contact closed circuit cooling tower, ICCCCT, were investigated experimentally. Different experiments were conducted involving the controlling parameters such as air velocity, spray water to air mass flow rate ratio, spray water flow rate, ambient air wet bulb temperature and the provided heat load to investigate their effects on the performance of the ICCCCT. Also the effect of using packing on the performance of the ICCCCT was investigated. It was noticed that these parameters affect the tower performance and the use of packing materials is a good approach to enhance the performance for different operational conditions. Correlations for mass and heat transfer coefficients are presented. The results showed a good agreement with other published works. Correlations are showed that the spray heat transfer coefficient is a function flow rates of spray water and air as well as spray water temperature while mass transfer coefficient is a function of spray water and air flow rates only.
Steel Reinforced Concrete (RC) frequently faces durability problems. In certain areas, Glass Fiber-Reinforced Polymer (GFRP) rebars are considered a non-corrodible substitute for steel reinforcement. Elevated temperatures have a significant impact on the mechanical characteristics and the adhesiveness of GFRP rebars to concrete, particularly when the polymeric matrix's glass transition temperature is approached or surpassed. Three simply supported reinforced concrete slabs were considered in the experimental program. Each specimen had identical dimensions of 1500×540×120 mm. For the fire resistance requirements, a 45 mm clear concrete cover and an exception of a 200 mm unexposed (cool) anchor zone at the ends were considered. The
... Show MoreHydrogen sulfide (H₂S) gas sensor based on cobalt–manganese spinel oxide MnCo₂O₄ thin films that were prepared by chemical precipitation and green synthesis methods. Structural, morphological, and compositional characterizations of MnCo₂O₄ thin films were performed using XRD, FE-SEM, EDS, and AFM. It was found through XRD patterns that MnCo₂O₄ was formed in a cubic spinel structure for both methods; however, the chemically precipitated thin films possessed better crystallinity and larger crystallite sizes, whereas the green-synthesized films exhibited slightly lower crystallinities and smaller sizes, as evidenced by the broader peaks observed. In addition, FE-SEM and AFM images revealed that the MnCo₂O₄ films prepared by
... Show MoreAg-doped NiO thin films were fabricated by dip coating and subsequently annealed at 373, 473, 573, and 673 K to elucidate the influence of annealing temperature on their structural, morphological, optical, and NO2-sensing characteristics. X-ray diffraction confirmed the formation of polycrystalline Ag/NiO films, with progressively improved crystallinity and larger crystallite size at elevated annealing temperatures. Atomic force microscopy revealed a homogeneous surface morphology with grain growth, with the average grain diameter increasing from 26.40 to 34.2 nm. Optical analysis showed high visible-region transmittance (65–70%) and a gradual reduction in the optical band gap from 2.75 to 2.07 eV with increasing annealing temperature. Ga
... Show MoreThis study investigates the influence of phosphoric acid (H3PO4) molarity (2 M, 4 M, and 6 M) on the structural, thermal, optical, and electrical properties of polyvinyl alcohol (PVA)/20% graphene oxide (GO) composite films. X-ray diffraction analysis revealed a semi-crystalline nature for PVA, with characteristic peaks at 19.7 degrees and 42 degrees, and crystalline peaks for GO at 10.1 degrees and 39.8 degrees. The addition of H3PO4 to the PVA/GO composite resulted in the disappearance of GO crystalline peaks, suggesting reduced crystallinity. Differential scanning calorimetry revealed a reduction in both glass transition and melting temperatures as H3PO4 concentration increased. Pure PVA exhibited Tg and Tm values of 68.9 degrees C and 1
... Show MoreA study of Zooplankton community has been carried out at four selected sites on Dukan Lake. Samples of water and zooplankton were collected monthly for the period from July 2015 to February 2016. Some physical and chemical properties of water were studied and the results showed that the air temperature were ranged from 0 to 36.16 °C, water temperature ranged from 2.83 to 34.66 °C, hydrogen ion concentration of studied sites were found to lie in alkaline side, it was ranged between 6.87 to 8.57, electrical conductivity ranged from 190.79 to 850.08 µs.cm¹, turbidity ranged from 0.9-7.7 NTU, and dissolved oxygen from 3.3 to 6.8 mg.l-¹ while BOD5 were ranged from 0.53 to 34.66 mg.l-¹. Concerning to the zooplankton, 37 species were ident
... Show MoreThe Evaluation of the immune response in Golden Hamsters experimentally infected with Leishmania donovani was determined in this study, particularly, the cellular immune response. Follow up has maintained to determine the Delayed Type of Hypersensitivity using skin test both in infected and control lab animals. Chicken red blood cells were used as a parameter to evaluate the immune system; they are dull and have the ability of immunization. Two concentrations of chicken R.B.C were examined to determine which gives the higher titration in Hamsters and those were 1.5 X 109 cell/ml and 3 X 109 cell/ml , the second concentration gave the maximum titration where then used in this work. After sensitization with Chicken R.B.C for both infected a
... Show MoreThe Evaluation of the immune response in Golden Hamsters experimentally infected with Leishmania donovani was determined in this study, particularly, the cellular immune response. Follow up has maintained to determine the Delayed Type of Hypersensitivity using skin test both in infected and control lab animals. Chicken red blood cells were used as a parameter to evaluate the immune system; they are dull and have the ability of immunization. Two concentrations of chicken R.B.C were examined to determine which gives the higher titration in Hamsters and those were 1.5 X 109 cell/ml and 3 X 109 cell/ml , the second concentration gave the maximum titration where then used in this work. After sensitization with Chicken R.B.C for both in
... Show MoreThis study proposes a hybrid predictive maintenance framework that integrates the Kolmogorov-Arnold Network (KAN) with Short-Time Fourier Transform (STFT) for intelligent fault diagnosis in industrial rotating machinery. The method is designed to address challenges posed by non-linear and non-stationary vibration signals under varying operational conditions. Experimental validation using the FALEX multispecimen test bench demonstrated a high classification accuracy of 97.5%, outperforming traditional models such as SVM, Random Forest, and XGBoost. The approach maintained robust performance across dynamic load scenarios and noisy environments, with precision and recall exceeding 95%. Key contributions include a hardware-accelerated K
... Show MoreObjectives: The study aims to evaluate the effectiveness of the educational program on nurses’ knowledge towards nursing management for patients undergoing percutaneous coronary intervention (PCI), as well as to find out the relationship between nurses' knowledge and some of their demographic characteristics (age, gender, level of education, and years of experience in cardiac units).
Methodology: A Quasi-experimental as one group (pre and post test) study was conducted at the Heart Center in Al-Diwaniyah city for the period from December 7, 2019 to February 23, 2020. A sample of (40) nurses working in the heart center was chosen from different nursing addresses. The sample covered one gro
... Show More