Preferred Language
Articles
/
joe-2210
Numerical Study of Optimum Configuration of Unconventional Airfoil with Steps and Rotating Cylinder for Best Aerodynamics Performance
...Show More Authors

Numerical study of separation control on symmetrical airfoil, four digits (NACA

0012) by using rotating cylinder with double steps on its upper surface based on the computation of Reynolds-average Navier- Stokes equations was carried out to find the optimum configuration of unconventional airfoil for best aerodynamics performance. A model based on collocated Finite Volume Method was developed to solve the governing equations on a body-fitted coordinate system. A revised (k-w) model was proposed as a known turbulence model. This model was adapted to simulate the control effects of rotating cylinder. Numerical solutions were performed for flow around unconventional airfoil with cylinder to main stream velocities ratio in the range of 1 to 4 and for various positions of the steps on the airfoil from the leading edge, 0.1c, 0.2c, 0.3c, 0.4c, 0.5c for the first step and 0.5c, 0.6c, 0.7c, 0.8c for the second step with constant step depth and length of 0.03c and 0.125c respectively. Reynolds number of 700,000 which was based on the cord length (c), with angle of attacks 0, 5, 8, 10, 12, 15 degrees was considered for the assessment of the unconventional airfoil performance. The numerical investigation showed that the optimum configuration for the unconventional airfoil was found to be at velocities ratio (U/U∞=4) with the steps positions at 0.5c and 0.8c for best airfoil performance.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
International Journal Of Low-carbon Technologies
Performance evaluation of the photovoltaic thermal system with a fin array and surface zigzag layout
...Show More Authors
Abstract<p>Solar photovoltaic (PV) has many environmental benefits and it is considered to be a practical alternative to traditional energy generation. The electrical conversion efficiency of such systems is inherently limited due to the relatively high thermal resistance of the PV components. An approach for intensifying electrical and thermal production of air-type photovoltaic thermal (PVT) systems via applying a combination of fins and surface zigzags was proposed in this paper. This research study aims to apply three performance enhancers: case B, including internal fins; case C, back surface zigzags; and case D, combinations of fins and surface zigzags; whereas the baseline smooth duct rep</p> ... Show More
View Publication
Scopus (17)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Wed Jan 04 2023
Journal Name
Frontiers In Chemestry
Thermal and flow performance analysis of a concentrated linear Fresnel solar collector with transverse ribs
...Show More Authors

This article deals with the impact of including transverse ribs within the absorber tube of the concentrated linear Fresnel collector (CLFRC) system with a secondary compound parabolic collector (CPC) on thermal and flow performance coefficients. The enhancement rates of heat transfer due to varying governing parameters were compared and analyzed parametrically at Reynolds numbers in the range 5,000–13,000, employing water as the heat transfer fluid. Simulations were performed to solve the governing equations using the finite volume method (FVM) under various boundary conditions. For all Reynolds numbers, the average Nusselt number in the circular tube in the CLFRC system with ribs was found to be larger than that of the plain abs

... Show More
Scopus (8)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sat Oct 16 2021
Journal Name
Energies
Performance Analysis of a Solar Cooling System with Equal and Unequal Adsorption/Desorption Operating Time
...Show More Authors

In solar-thermal adsorption/desorption processes, it is not always possible to preserve equal operating times for the adsorption/desorption modes due to the fluctuating supply nature of the source which largely affects the system’s operating conditions. This paper seeks to examine the impact of adopting unequal adsorption/desorption times on the entire cooling performance of solar adsorption systems. A cooling system with silica gel–water as adsorbent-adsorbate pair has been built and tested under the climatic condition of Iraq. A mathematical model has been established to predict the system performance, and the results are successfully validated via the experimental findings. The results show that, the system can be operational

... Show More
View Publication
Scopus (13)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Wed Jun 01 2016
Journal Name
Journal Of Engineering
Experimental and Simulation for the Effect of Partial Shading on Solar Panel Performance
...Show More Authors

Partial shading is one of the problems that affects the power production and the efficiency of photovoltaic module. A series of experimental work have been done of partial shading of   monocrystalline PV module; 50W, Isc: 3.1A, Voc: 22V with 36 cells in series is achieved. Non-linear power output responses of the module are observed by applying various cases of partial shading (vertical and horizontal shading of solar cells in the module). Shading a single cell (corner cell) has the greatest impact on output energy. Horizontal shading or vertical shading reduced the power from 41W to 18W at constant solar radiation 1000W/m2 and steady state condition. Vertical blocking a column

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 27 2022
Journal Name
Arabian Journal For Science And Engineering
Optical and Thermal Performance of a Parabolic Trough Collector for Different Receiver Geometries
...Show More Authors

This paper numerically and theoretically investigates the optical and thermal performance of a parabolic trough collector PTC system. Many numerical simulations and theoretical analyses are conducted to demonstrate the influence of the receiver geometry and shifting from the focal position on the optical performance. The examined receiver geometries are circular, square, triangular, elliptical, and the new circular–square combined geometry is named as channel receiver. The thermal performance of PTC is examined for different volume flow rates theoretically in the range of (0.36 to 2.4 lpm). The results show that the best optical design is the channel receiver with an intercept factor of 84%, while the worst is the elliptical receiver with

... Show More
View Publication
Scopus (19)
Crossref (11)
Scopus Crossref
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Evaluating the performance of Inspector General Office of the Ministry of health in accordance with normative people and people results for the European excellence model EFQM 2013
...Show More Authors

Abstract:

Current research has sought to apply the criteria of potential for altmizalaorbi model EFQM 2013 in assessing the performance of the Inspector General's Office/Ministry of health, so as to keep up with a modern and advanced management methods in the evaluation of performance, as well as to link performance to a citizen's life, and it takes him beyond the accepted service capabilities today, but of budget duties between dealers servicing responsibilities and future planning, financial control, competitiveness, human resources needs and maintaining quality and development, as well as the constant quest for continuous improvement, is the spirit of the principle underpinning the European Foundation Quality managemen

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Aug 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Evaluating the performance of Inspector General office of the Ministry of health in accordance with normative people and people results for the European excellence model EFQM 2013
...Show More Authors

Current research sought to evaluate the performance and results of employees in accordance with normative to people and people result for the European model of excellence EFQM 2013 quality management Foundation in the Inspector General's Office/Ministry of health, so as to pursue a modern and advanced management methods in evaluating performance and the performance of the Office's relationship with a citizen's life, since it takes him beyond the accepted service capabilities today, but it became budget duties between dealers servicing responsibilities and future planning, financial control, competitiveness, human resources needs and maintaining quality and continuous improvement and development as well as The primary role of the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Sep 08 2020
Journal Name
Baghdad Science Journal
The Suggested Reciprocal Relationship between Maximum, Minimum and Optimum Usable Frequency Parameters Over Iraqi Zone
...Show More Authors

In this work, the relationship between the ionospheric parameters (Maximum Usable Frequency (MUF), Lowest Usable Frequency (LUF) and Optimum working Frequency (OWF)) has been studied for the ionosphere layer over the Iraqi zone. The capital Baghdad (44.42oE, 33.32oN) has been selected to represent the transmitter station and many other cities that spread over Iraqi region have represented as receiver stations. The REC533 communication model considered as one of the modern radio broadcasting version of ITU has been used to calculate the LUF parameter, while the MUF and OWF ionospheric parameters have been generated using ASAPS international communication model which represents one of the most advanced  and

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue Sep 08 2020
Journal Name
Baghdad Science Journal
The Suggested Reciprocal Relationship between Maximum, Minimum and Optimum Usable Frequency Parameters Over Iraqi Zone
...Show More Authors

In this work, the relationship between the ionospheric parameters (Maximum Usable Frequency (MUF), Lowest Usable Frequency (LUF) and Optimum working Frequency (OWF)) has been studied for the ionosphere layer over the Iraqi zone. The capital Baghdad (44.42oE, 33.32oN) has been selected to represent the transmitter station and many other cities that spread over Iraqi region have represented as receiver stations. The REC533 communication model considered as one of the modern radio broadcasting version of ITU has been used to calculate the LUF parameter, while the MUF and OWF ionospheric parameters have been generated using ASAPS international communication model which represents one of the most advanced  and accurate HF sky wave prop

... Show More
View Publication
Scopus (11)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sat Jan 13 2018
Journal Name
Journal Of Engineering
Zn(II) Removal from Wastewater by Electrocoagulation/Flotation Method using New Configuration of a Split-Plate Airlift Electrochemical Reactor
...Show More Authors

In this paper, split-plate airlift electrochemical reactor as an apparatus with new configuration for wastewater treatment was provided. Two aluminum plates were fixed inside the reactor and present two functions; first it works as split plates for internal loop generation of the airlift system (the zone between the two plates acts as riser while the other two zones act as downcomer) and second it works as two electrodes for electrocoagulation process. Simulated wastewater contaminated with zinc ions was used to test the performance of this apparatus for zinc removal by studying the effect of different experimental variables such as initial concentration of zinc (50-800 ppm), electrical current density (2.67-21.4 mA/cm2), init

... Show More
View Publication Preview PDF