Preferred Language
Articles
/
joe-2209
Analysis and Control of PWM Buck-Boost AC Chopper Fed Single-Phase Capacitor Run Induction Motor
...Show More Authors

Single phase capacitor-run induction motors (IMs) are used in various applications such as home appliances and machine tools; they are affected by the sags or swells and any fault that can lead to disturb the supply and make it produce rms voltage below or above the rated motor voltage, which is 220V. A control system is designed to regulate the output voltage of the converter irrespective to the variation of the load and within a specific range of supply voltage variation. The steady-state equivalent circuit of the Buck-Boost chopper type AC voltage regulator, as well as the analysis of this circuit are presented in this paper. Switching device for the regulator is an IGBT Module. The proposed chopper uses pulse width modulation (PWM) control technique to chop the input voltage into segments in order to guarantee rated rms voltage supplied to the load, which is capacitor-run induction motor. Proportional integral (PI) controller is used to obtain very small steady state error, stable and fast dynamic response, and robustness against variations in the line voltage. The complete system is simulated using software package, and the results are obtained to verify the proposed control method.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Aug 01 2021
Journal Name
Journal Of Physics: Conference Series
EEG Motor-Imagery BCI System Based on Maximum Overlap Discrete Wavelet Transform (MODWT) and cubic SVM
...Show More Authors
Abstract<p>Communication of the human brain with the surroundings became reality by using Brain- Computer Interface (BCI) based mechanism. Electroencephalography (EEG) being the non-invasive method has become popular for interaction with the brain. Traditionally, the devices were used for clinical applications to detect various brain diseases but with the advancement in technologies, companies like Emotiv, NeuoSky are coming up with low cost, easily portable EEG based consumer graded devices that can be used in various application domains like gaming, education etc as these devices are comfortable to wear also. This paper reviews the fields where the EEG has shown its impact and the way it has p</p> ... Show More
View Publication
Scopus (6)
Crossref (4)
Scopus Crossref
Publication Date
Thu Oct 31 2013
Journal Name
Al-khwarizmi Engineering Journal
Pressure Control of Electro-Hydraulic Servovalve and Transmission Line Effect
...Show More Authors

The effected of the long transmission line (TL) between the actuator and the hydraulic control valve sometimes essentials. The study is concerned with modeling the TL which carries the oil from the electro-hydraulic servovalve to the actuator. The pressure value inside the TL has been controlled by the electro-hydraulic servovalve as a voltage supplied to the servovalve amplifier. The flow rate through the TL has been simulated by using the lumped π element electrical analogy method for laminar flow. The control voltage supplied to servovalve can be achieved by the direct using of the voltage function generator or indirect C++ program connected to the DAP-view program built in the DAP-card data acqu

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 25 2020
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Evaluation of Hepatocyte Growth Factor in Iraqi Patients with Acute Myeloid Leukemia: Its Correlation with Clinical Parameters and Response to Induction Therapy
...Show More Authors

BACKGROUND: Hepatocyte growth factor (HGF) is a proangiogenic factor that exerts different effects over stem cell survival growth, apoptosis, and adhesion. Its impact on leukemogenesis has been established by many studies. AIM: This study aimed to determine the effect of plasma HGF activity on acute myeloid leukemia (AML) patients at presentation and after remission. PATIENTS AND METHODS: This was a cross-sectional prospective study of 30 newly-diagnosed, adult, and AML patients. All patients received the 7+3 treatment protocol. Patients’ clinical data were taken at presentation, and patients were followed up for 6 months to evaluate the clinical status. Plasma HGF levels were estimated by ELISA based methods in the pa

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Fri Dec 31 2021
Journal Name
Journal Of Peace For Humanities And Social Sciences Jphsc
The Role of Contract Duration in the Pre-Contractual Phase
...Show More Authors

Time crosses one of the most important principles that are agreed upon in contracts, because the temporal dimension has a significant impact on all contract provisions and is not limited to a certain group of them. French and Arab legal jurists alike called for this dimension to be given special attention. That is the term of the contract term; To try to limit the temporal elements, clarify their provisions and distinguish between them, but in the Arab world it did not receive the same attention that it received in the West.

View Publication
Publication Date
Tue Mar 20 2018
Journal Name
Offshore Technology Conference Asia
Prediction of Hydrate Phase Equilibrium Conditions for Different Gas Mixtures
...Show More Authors
Abstract<p>Gas hydrate formation poses a significant threat to the production, processing, and transportation of natural gas. Accurate predictions of gas hydrate equilibrium conditions are essential for designing the gas production systems at safe operating conditions and mitigating the problems caused by hydrates formation. A new hydrate correlation for predicting gas hydrate equilibrium conditions was obtained for different gas mixtures containing methane, nitrogen and carbon dioxide. The new correlation is proposed for a pressure range of 1.7-330 MPa, a temperature range of 273-320 K, and for gas mixtures with specific gravity range of 0.553 to 1. The nonlinear regression technique was applie</p> ... Show More
Scopus (6)
Scopus Crossref
Publication Date
Tue Dec 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance Evaluation of Three Phase Spray Direct Contact Heat Exchanger
...Show More Authors

 

The present investigation deals with experimental study of three-phase direct-contact heat exchanger, for water-Freon R11 system, where water is the continuous phase (liquid) and Freon R11 (liquid-gas) is the dispersed phase. The test section consisted of a cylindrical Perspex column with inner diameter 8cm and 1.2m long, in which, water was to be confined. Liquid Freon R11 drops were injected into the hot water filled column, through a special design of distributors at the bottom of the column. The liquid Freon R11 drops rose on their way up and evaporated into two-phase bubbles at atmospheric pressure. The study was devoted to express the effect of process variables such as c

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 30 2017
Journal Name
Al-khwarizmi Engineering Journal
Design & Implementation of High Switching & Low Phase Noise Frequency Synthesizer
...Show More Authors

This research  describes the design & implementation of frequency synthesizer using single loop Phase lock loop with the following specifications: Frequency range (1.5 – 2.75) GHz,Step size (1 MHz), Switching time 36.4 µs, & phase noise @10 kHz = -92dBc & spurious -100 dBc

  The development in I.C. technology provide the simplicity in the design of frequency synthesizer because it implements the phase frequency detector(PFD) , prescalar &  reference divider in single chip. Therefore our system consists of  a single chip contains (low phase noise PFD, charge pump, prescalar  & reference divider), voltage controlled oscillator , loop filter & reference oscillator. The single chip

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance Comparison between Recycled Single Stage and Double Stage Hydrocyclones
...Show More Authors

   This research presents a comparison of performance between recycled single stage and double stage hydrocyclones in separating water from water/kerosene emulsion. The comparison included several factors such as: inlet flow rate (3,5,7,9, and 11 L/min), water feed concentration (5% and 15% by volume), and split ratio (0.1 and 0.9). The comparison extended to include the recycle operation; once and twice recycles. The results showed that increasing flow rate as well as the split ratio enhancing the separation efficiency for the two modes of operation. On the contrary, reducing the feed concentration gave high efficiencies for the modes. The operation with two cycles was more efficient than one cycle. The maximum obtained effici

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Nov 16 2020
Journal Name
The Imaging Science Journal
Single image dehazing by dark channel prior and luminance adjustment
...Show More Authors

View Publication
Scopus (10)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Journal Of Engineering
National Grid Connected 3-Phase Inverter based on Photovoltaic Solar System
...Show More Authors

In this paper, a national grid-connected photovoltaic (PV) system is proposed. It extracts the maximum power point (MPP) using three-incremental-steps perturb and observe (TISP&O) maximum power point tracking (MPPT) method. It improves the classic P&O by using three incremental duty ratio (ΔD) instead of a single one in the conventional P and O MPPT method. Therefore, the system's performance is improved to a higher speed and less power fluctuation around the MPP. The Boost converter controls the MPPT and then is connected to a three-phase voltage source inverter (VSI). This type of inverter needs a high and constant input voltage. A second-order low pass (LC) filter is connected to the output of VSI to reduce t

... Show More
View Publication Preview PDF
Crossref (3)
Crossref