Preferred Language
Articles
/
joe-2197
Energy Savings in Thermal Insulations for Sustainable Buildings
...Show More Authors

Energy use is second to staffing in building operating costs. Sustainable technology in the energy sector is based on utilizing renewable sources of energy such as solar, wind, glazing systems, insulation. Other areas of focus include heating, ventilation and air conditioning; novel materials and construction methods; improved sensors and monitoring systems; and advanced simulation tools that can help building designers make more energy efficient choices. The objective of this research is studying the effect of insulations on energy consumption of buildings in Iraq and identifying the amount of energy savings from application the insulations in buildings. HAP (Hourly Analysis Program) is used to calculate the thermal loads and the amount of energy needed. It is concluded that the use of the thermal insulation in the roof, walls, floors, and double glazing system for windows in building effectively reduces the energy required for air conditioning.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Advanced Composites Letters
Enhanced thermal and electrical properties of epoxy/carbon fiber–silicon carbide composites
...Show More Authors

The silicon carbide/carbon fiber (SiC/CF) hybrid fillers were introduced to improve the electrical and thermal conductivities of the epoxy resin composites. Results of Fourier transform infrared spectroscopy revealed that the peaks at 3532 and 2850 cm−1 relate to carboxylic acid O–H stretching and aldehyde C–H stretching appearing deeper with an increased volume fraction of SiC. Scanning electron microscopic image shows a better interface bonding between the fiber and the matrix when the volume fraction of SiC particles are increased. As frequency increases from 102 Hz to 106 Hz, dielectric constants decrease slightly. Dissipation factor (tan δ) values keep low a

... Show More
View Publication
Scopus (31)
Crossref (39)
Scopus Clarivate Crossref
Publication Date
Mon Jan 02 2023
Journal Name
Baghdad Science Journal
Synthesis, Characterization, and Thermal Analysis of a New Acidicazo Ligand's Metal Complexes
...Show More Authors

The researchers wanted to make a new azo imidazole as a follow-up to their previous work. The ligand 4-[(2-Amino-4-phenylazo)-methyl]-cyclohexane carboxylic acid as a derivative of trans-4- (aminomethyl) cyclohexane carboxylic acid diazonium salt, and synthesis a series of its chelate complexes with metalions, characterized these compounds using a variety technique, including elemental analysis, FTIR, LC-Mass, 1H-NMRand UV-Vis spectral process as well TGA, conductivity and magnetic quantifications. Analytical data showed that the Co (II) complex out to 1:1 metal-ligand ratio with square planner and tetrahedral geometry, respectively while 1:2 metal-ligand ratio in the Cu(II), Cr(III), Mn(II), Zn(II), Ru(III)and Rh(III)complexes with octahed

... Show More
Scopus (40)
Crossref (13)
Scopus Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Materials Science-poland
Electrical and thermal characteristics of MWCNTs modified carbon fiber/epoxy composite films
...Show More Authors
Abstract<p>To enhance interfacial bonding between carbon fibers and epoxy matrix, the carbon fibers have been modified with multiwall carbon nanotubes (MWCNTs) using the dip- coating technique. FT-IR spectrum of the MWCNTs shows a peak at 1640 cm<sup>−1</sup> corresponding to the stretching mode of the C=C double bond which forms the framework of the carbon nanotube sidewall. The broad peak at 3430 cm<sup>−1</sup> is due to O–H stretching vibration of hydroxyl groups and the peak at 1712 cm<sup>−1</sup> corresponds to the carboxylic (C=O) group attached to the carbon fiber. The peaks at 2927 cm<sup>−1</sup> and 2862 cm<sup>−1</sup> ar</p> ... Show More
View Publication
Scopus (48)
Crossref (45)
Scopus Clarivate Crossref
Publication Date
Sun Mar 15 2020
Journal Name
Al-academy
The Role of the Passive Conditioning in Achieving Thermal Comfort in Temporary Hotel Units: سماح محمد طالب الدويك-سامي أبوطالب-محمد صابر
...Show More Authors

This research is based on monitoring the local and environmental technologies in the design of the temporary hotel units (nomadic tents) in the desert in the south of Jordan in order to air condition them in summer and winter, maintaining the Jordanian identity, that they are presented with the form and technologies of the age in order to get to the universality.
The research adopted the descriptive analytical method and the researcher conducted the analysis of SWOT specified for the analysis of the positive and negative aspects in the design of the temporary hotel units and comparing them with the case studies available in the chosen research area "the Jordanian golden triangle", through the elements of the case under study. The res

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
INTERACTION EFFECTS OF HYDRODYNAMICALLY FULLY DEVELOPED PRIMARY FLOW AND SECONDARY FLOW IN THE THERMAL ENTRANCE REGION OF ANNULAR DUCT
...Show More Authors

Experiments have been conducted to study the local and average heat transfer by mixed
convection for hydrodynamically fully developed, thermally developing and fully developed
laminar upward air flow in an inclined annulus with adiabatic inner cast iron tube and uniform
heated outer aluminum tube with an aspect ratio ( Ω = 0.72) and (L/Dh≈40) for both calming and
test sections). A wide range of Reynolds number from 859 to 2024 has been covered, and heat
flux has been varied from 159 W/m2 to 812 W/m2 (these values of heat flux and Reynolds
number gave Richardson number range from 0.03 to 0.٣٨), with angles of annulus inclination
φ =0o (horizontal position), φ =60o (inclined position), and φ =90o (vertical posi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Oct 01 2020
Journal Name
International Communications In Heat And Mass Transfer
Thermal behaviour of the flow boiling of a complex nanofluid in a rectangular channel: An experimental and numerical study
...Show More Authors

View Publication
Scopus (28)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Mon Feb 25 2019
Journal Name
Iraqi Journal Of Physics
Simulation of thermal lensing in an end-pumped Nd:YAG laser rod with Gaussian and super-Gaussian pump beam profile
...Show More Authors

A numerical simulation is made on the thermal lensing effect in an laser diode end-pumped Nd:YAG laser rod. Based on finite element method (FEM), the laser rod temperature distribution is calculated and the focal length is deduced for a Gaussian and super-Gaussian pump beam profiles.

At the pump power of 20W, the highest temperature located at the center of end-pumped face was 345K, and the thermal lens focal length was 81.4mm along the x-z axis. 

The results indicate that the thermal lensing effect sensitively depend on the pump power, waist radius of the pump beam and the pump distribution in a laser rod geometry.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Energy Storage
Intensifying the thermal response of PCM via fin-assisted foam strips in the shell-and-tube heat storage system
...Show More Authors

View Publication
Scopus (71)
Crossref (59)
Scopus Clarivate Crossref
Publication Date
Tue Jun 18 2024
Journal Name
Heat Transfer Engineering
Boosting Solidification Rates in a Triplex-Tube Thermal Storage System Using Circular Fins: Novel Staggered and Inline Fin Arrangements
...Show More Authors

View Publication
Scopus (7)
Crossref (8)
Scopus Crossref
Publication Date
Mon Aug 01 2016
Journal Name
Journal Of Engineering
Modeling and Simulation of Thermal Performance of Solar-Assisted Air Conditioning System under Iraq Climate
...Show More Authors

In Iraq most of the small buildings deployed a conventional air conditioning technology which typically uses electrically driven compressor systems which exhibits several clear disadvantages such as high energy consumption, high electricity at peak loads. In this work a thermal performance of air conditioning system combined with a solar collector is investigated theoretically. The hybrid air conditioner consists of a semi hermetic compressor, water cooled shell and tube condenser, thermal expansion valve and coil with tank evaporator. The theoretical analysis included a simulation for the solar assisted air-conditioning system using EES software to analyze the effect of different parameters on the power consumption of c

... Show More
View Publication Preview PDF