Effect of Steel Fibers on the Properties of Refractory Free Cement Concrete
...Show More Authors

Free cement refractory concrete is a type of refractory concrete with replacing alumina cement by bonding materials such as white kaolin, red kaolin and fumed silica. The free cement refractory concrete used in many applications like Petrochemicals, iron furnaces and cement production industries. The research clarifies the effect of steel fibers with two types crimped steel fibers and hooked steel
fibers with percentages 0.5%, 1% and 1.5% by volume from weight of bauxite aggregates. The additions of steel fibers with two types gave good properties in high temperatures where the specimens keep the dimension without failure and the properties made the best. the percentage of increasing for thermal conductivity was 44% for 1.5% crimped fibers and 42.8% for 1.5% hooked end fibers and the percentage increasing in bulk density of free cement refractory concrete was 30% for 1.5% crimped fibers and 27% for 15% hooked end fibers . From this study can be concluded that the best types of steel fibers which used in free cement refractory concrete is the crimped type with percentage 1.5%.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the effect of local exogenous application of osteopontin on wound healing in rats
...Show More Authors

Background: Wound healing is a complex dynamical interaction between various cell types, the extracellular matrix, cytokines, and growth factors. osteoponetin is a substance that acts as an anti-inflammatory. Aims of study: The study was designed to identify the role of local exogenous applications of osteopontin on wound healing (in cheek skin). Materials and methods: Thirty adult male albino rats weighting an average of (250-300gm) used in this study, incisional wounds were made in the skin of the cheek of rat and they were divided into the following groups: A-Control group: 15 rats treated with 1µ l of normal saline B-Experimental groups: 15 rats treated with topical application of 1µl osteopontin. The scarification of animals we

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Wed Jan 04 2017
Journal Name
Iraqi Journal Of Science
Histological study of the Isotretinoin drug effect on the intrauterine prenatal development in the pregnant mice
...Show More Authors

Publication Date
Sat Feb 20 2021
Journal Name
International Journal Of Research In Social Sciences And Humanities
THE EFFECT OF THE ELECTRONIC ENVIRONMENT ON WORK ETHICS (APPLIED RESEARCH IN THE NATIONAL INSURANCE COMPANY)
...Show More Authors

View Publication
Crossref
Publication Date
Tue Dec 01 2009
Journal Name
Journal Of Economics And Administrative Sciences
The Effect of Administrative Accounting Functions on the Practices of the Higher and Central Administrations of the Economic Unit "An Applied Study on Joint Stock Companies"
...Show More Authors

Strategy Descrtibes How an Organization Matches its own Capabilites With Opportunities in Environment , in Order to Accomplish its Overall Objectives , So That The Organization is Considering Responding to Challenges by Adopting one or More of Strategies, Like Differentioning its Product, or Achieving Cost Leadership.

The Key Role of Management Accountant is to Evlaute The Successful it Has Been in Implementing Organization Strategy.

This Research Target to Explain The Key Role of Management Accountant in Evaluate of  Organization Strategy. by Strategic Analysis of Operating Income From Specific Sources Such as Cost Savings and Growth in Stead of Emphasizing Only The Aggrega

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri May 31 2019
Journal Name
Journal Of Engineering
Moisture Damage of Warm Mix Asphalt Concrete
...Show More Authors

Implementation of Warm Mix Asphalt concrete (WMA) is getting global acceptance due to the restrictions for protecting the environment and the requirements to reduce fuel consumption. In this investigation, two WMA mixtures have been prepared in the laboratory using medium curing cutback (MC-30) and Cationic emulsion asphalt. Hot Mix Asphalt (HMA) was also prepared for comparison. The cylinder specimens (63.5mm) in height and (101.6mm) in diameter were constructed from the mixtures and subjected to indirect tensile strength test to determine the Tensile Strength Ratio (TSR). The cylinder specimens of (101.6mm) in height and (101.6mm) in diameter were also constructed from those mixtures and subjected to static compressive

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Apr 07 2018
Journal Name
Civil Engineering Journal
Behavior of Precast Prestressed Concrete Segmental Beams
...Show More Authors

The structural behavior of Segmental Precast Post-tensioned Reinforced Concrete (SPPRC) beams largely depends on the behavior of the joints that connect between the segments. In this research, series of static tests were carried out to investigate the behavior of full-scale SPPRC beams with different types of epoxy-glued joint configurations; multi-key joint, single key, and plain key joint. The reference specimen was monolithically casted beam and the other specimens were segmental beams with five segments for each one. The general theme from the experimental results reflects an approximate similarity in the behavior of the four beams with slight differences. Due to the high tensile strength of the used epoxy in comparison to concr

... Show More
Crossref (13)
Clarivate Crossref
Publication Date
Wed Nov 03 2021
Journal Name
Journal Of Engineering Research
Performance of quadrilateral perforated prestressed concrete rafters
...Show More Authors

This study focuses on the behavior of simply supported perforated prestressed concrete rafters (PPCRs) under single midspan monotonic static loading. The experimental program consisted of testing seven specimens; one solid (control) rafter, and six perforated with quadrilateral openings. The main investigated variables are the number and height of the openings. The test findings indicate that, in comparison to the solid rafter, the presence of quadrilateral openings in the PPCRs led to reducing the load capacity by (4.3-36%) and increase the midspan deflection at ultimate by (14.8-33%). Also, increasing the number of concrete posts between openings resulted in increasing the failure load and decreasing the deflection at all stages o

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Corrosion-Resistance Characteristics of Concrete Containing Furfural
...Show More Authors

Corrosion inhibiting admixtures are unique among other methods to protect reinforced concrete from corrosion damage. In this study, the effect of furfural on the fresh and hardened properties of concrete mixes of 35 and 45 MPa compressive strengths as well as the corrosion inhibition of furfural was evaluated. Furfural was added at different dosages (1, 2 and 3% by weight of cement) with and without superplasticizer (HRWR). Different electrochemical measurements were performed (Half-cell potential, Tafel plot and linear polarization resistance). Electrochemical measurements confirmed that furfural dramatically reduces the rate of corrosion; the inhibition efficiencies were 62.7 and 63.8 % due to 3% furfural addition to 35 and 45MPa-concr

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Sep 01 2022
Journal Name
Engineering Structures
Mesoscale analysis of Fiber-Reinforced concrete beams
...Show More Authors

Crossref (19)
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Engineering
Some Durability Test of No-Fine Concrete
...Show More Authors

In this study, two types of mixes were adopted by using two grading of coarse aggregate. The practical side of this study was to produce no-fine aggregate concrete by using crushed clay brick aggregates. The durability of the produced concrete and internal sulfate attack was studied.      For durability assessment, it is found that the no-fine concrete made with crushed brick aggregate lost about (15-25) % of its compressive strength after being subjected to 60 cycles of wetting and drying with age 120 days. The curing condition showed that the water curing improved the compressive strength with a rate higher than that when sealed or air dry curing were used. The crushed brick no-fine concrete de