The present study focused mainly on the buckling behavior of composite laminated plates subjected to mechanical loads. Mechanical loads are analyzed by experimental analysis, analytical analysis (for laminates without cutouts) and numerical analysis by finite element method (for laminates with and without cutouts) for different type of loads which could be uniform or non-uniform, uniaxial or biaxial. In addition to many design parameters of the laminates such as aspect ratio, thickness ratio, and lamination angle or the parameters of the cutout such as shape, size, position, direction, and radii rounding) which are changed to studytheir effects on the buckling characteristics with various boundary conditions. Levy method of classical laminated plate theory and Finite element coded by ANSYS 13.0 is used to formulate the theoretical model. Results are compared with other researches and good agreement was obtained.
Background: Carpal tunnel syndrome (CTS) is the most prevalent upper-limb entrapped neuropathy. A nerve conduction study (NCS) is the simplest method for identifying CTS when combined with a satisfactory clinical assessment and physical assessment. Ultrasound is a beneficial non-traumatic screening approach for CTS and there is a relationship between the NCS tests and the measures of CSA by ultrasound. Objective: to assess whether or not sonographic observations of the median nerve seems to be varied amongst DM and non-DM CTS individual. Patients and methods: The total of 50 non-DM Individuals with CTS and 50 DM individuals with CTS have been included in this study. All individuals were submitted to full medical assessment NCS testi
... Show MoreThe temperature influence on the fluorescence lifetime, quantum yields and non-radiative rate parameter or coumarin 460 dye dissolved in methanol was investigated in the temperature range (160-300 k). A single photon counting technique was used or measuring the fluorescence decay curves. A noticeable decrease of the fluorescence lifetime with increasing the temperature was observed. The non-radiative activation energy of 10.57 K.J. mole-1 was measured by the help of Arrhenius plot.
Prednisolone (SAID) was conjugated with ibuprofen (NSAID) through an amino acid (glycine) as a spacer arm to synthesize the following compound:
Prednisolone – glycine – ibuprofen.
The method employed consists of converting the carboxylic acid function of (R,S) – ibuprofen – glycine to the highly reactive acid chloride and subsequent reaction with the C21 hydroxyl group of prednisolone. This reactive intermediate was found to react as well with the C17 tertiary hydroxyl group of the steroid to form three compounds and eight diastereomers. These results were confirmed by T.L.C, and the desired compound was separated by column chromatograph
... Show More
The present study is about tales attributed to certain people and are not traded. Such a study has a great importance for religion scholars and conveyors of hadiths since it is considered as one of the important sources of Islamic legislation that represent the Holy Sunna, and the majority of the recent study is concerned with non-traded tales of religion scholars. The research starts with the definition of such type of tales and then its types, conditions, legality, exceptions, and the benefit from studying such matter. It is mainly concerned with the opinions of the Imami and Hanafi region scholars respectively, and with comparing between the two doctrines i.e. Imami and Hanafi at the end of each
... Show MoreThis paper considers and proposes new estimators that depend on the sample and on prior information in the case that they either are equally or are not equally important in the model. The prior information is described as linear stochastic restrictions. We study the properties and the performances of these estimators compared to other common estimators using the mean squared error as a criterion for the goodness of fit. A numerical example and a simulation study are proposed to explain the performance of the estimators.
Water contamination is a pressing global concern, especially regarding the presence of nitrate ions. This research focuses on addressing this issue by developing an effective adsorbent for removing nitrate ions from aqueous solutions. two adsorbents Chitosan-Zeolite-Zirconium (Cs-Ze-Zr composite beads and Chitosan-Bentonite-Zirconium Cs-Bn-Zr composite beads were prepared. The study involved continuous experimentation using a fixed bed column with varying bed heights (1.5 and 3 cm) and inlet flow rates (1 and 3 ml/min). The results showed that the breakthrough time increased with higher bed heights for both Cs-Ze-Zr and Cs-Bn-Zr composite beads. Conversely, an increase in flow rate led to a decrease in breakthrough time. Notab
... Show MoreFiber reinforced polymer composite is an important material for structural application. The diversified application of FRP composite has taken center of attraction for interdisciplinary research. However, improvements on mechanical properties of this class of materials are still under research for different applications. In this paper we have modified the epoxy matrix by Al2O3, SiO2 and TiO2 nano particles in glass fiber/epoxy composite to improve the mechanical and physical properties. The composites are fabricated by hand lay-up method. It is observed that mechanical properties like flexural strength, hardness are more in case of SiO2 modified epoxy composite compare to other nano
... Show MoreBackground: The microhardness of a composite resin is a vital parameter that is used to determine its clinical behavior. Measuring the microhardness of a composite resin has been used as an indirect method to assess its degree of conversion and extent of polymerization. The purpose of this in vitro study was to evaluate the effect of three curing distances (0, 2, and 4 mm) on the microhardness of the top and bottom surfaces of three types of flowable bulk-fill composite resins (smart dentin replacement, Opus bulk fill flow, and Tetric N). Material and method: Sixty-three specimens from the three types of composite resins (n=21) were fabricated using Teflon mold with a 4mm depth and a 5 mm internal diameter and cured for 20 seconds. For e
... Show More