Buckling Analysis Of Damaged Composite Plates Under Uniform Or Non-Uniform Compressive Load
...Show More Authors

The present study focused mainly on the buckling behavior of composite laminated plates subjected to mechanical loads. Mechanical loads are analyzed by experimental analysis, analytical analysis (for laminates without cutouts) and numerical analysis by finite element method (for laminates with and without cutouts) for different type of loads which could be uniform or non-uniform, uniaxial or biaxial. In addition to many design parameters of the laminates such as aspect ratio, thickness ratio, and lamination angle or the parameters of the cutout such as shape, size, position, direction, and radii rounding) which are changed to studytheir effects on the buckling characteristics with various boundary conditions. Levy method of classical laminated plate theory and Finite element coded by ANSYS 13.0 is used to formulate the theoretical model. Results are compared with other researches and good agreement was obtained.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
J. Mech. Cont.& Math. Scis
The Use of Non-Parametric Methods to Estimate Density Functions of Copulas
...Show More Authors

Publication Date
Wed May 03 2017
Journal Name
Petroleum Science And Technology
Investigation of non-Newtonian flow characterization and rheology of heavy crude oil
...Show More Authors

View Publication
Crossref (34)
Crossref
Publication Date
Tue Mar 26 2024
Journal Name
World Electric Vehicle Journal
Fast Finite-Time Composite Controller for Vehicle Steer-by-Wire Systems with Communication Delays
...Show More Authors

The modern steer-by-wire (SBW) systems represent a revolutionary departure from traditional automotive designs, replacing mechanical linkages with electronic control mechanisms. However, the integration of such cutting-edge technologies is not without its challenges, and one critical aspect that demands thorough consideration is the presence of nonlinear dynamics and communication network time delays. Therefore, to handle the tracking error caused by the challenge of time delays and to overcome the parameter uncertainties and external perturbations, a robust fast finite-time composite controller (FFTCC) is proposed for improving the performance and safety of the SBW systems in the present article. By lumping the uncertainties, parameter var

... Show More
View Publication
Scopus (15)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Thu Jan 30 2020
Journal Name
Journal Of Engineering
Study Impact of Unified Power Flow Controller (UPFC) on a Transmission Line Performance under Different Loading Conditions
...Show More Authors

Now-a-days the Flexible AC Transmission Systems (FACTS) technology is very effective in improving the power flow along the transmission lines and makes the power system more flexible and controllable. This paper deals with the most robust type of FACTS devices; it’s a Unified Power Flow Controller (UPFC). Many cases have been taken to study how the system behaves in the presence and absence of the UPFC under normal and contingency conditions. The UPFC is a device that can be used to improve the bus voltage, increasing the loadability of the line and reduce the active and reactive power losses in the transmission lines, through controlling the flow of real and reactive power. Both the magnitude and the phase angle of th

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Nov 09 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment of Severity of Anemia Among Children Under 5 Years
...Show More Authors

Objective(s): The aim of this study was to assess the severity of anemia among children under 5 years and to find
out relationship between severity of anemia in children with socio-demographic variables such as: child gender,
age, supplement diet, hookworm, pica, parent's education level, father's and mother's occupation, and family
monthly income with severity of anemia
Methodology: A descriptive cross sectional study was conducted at the primary health care centers in Alsadr city
for the period of 1
st July 2011 to the 1st November 2011.Non probability (purposive) sample of (630) children who
aged under 5 years and who attended to primary health care centers of Alsadr city. The data were collected
through using

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 31 2019
Journal Name
Journal Of Engineering
Experimental Study of Solar Still Under Influence of Various Conditions
...Show More Authors

In the present work, experimental tests was done to explain the effect of insulation and water level on the yield output. Linear basin, single slope solar still used to do this purpose. The test was done from May to August 2017 in Mosul City-Iraq (Latitude: Longitude: Elevation: 200 m, and  South-East face). Experimental results showed that the yield output of the still increased by 20.785% and 19.864% in case of using thermal insulation at 4cm and 5cm respectively, also the yield output decrease by 15.134% as the water level increase from 4 to 5cm, with the presence of insulation and 14.147% without it. It has been conclude that the insulation and water level play important role in the process of passive

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Aug 01 2022
Journal Name
Journal Of Engineering
Production of Load Bearing Concrete Masonry Units (blocks) From Green Concrete Containing Plastic Waste and Nano Silica Sand Powder
...Show More Authors

Industrial development has recently increased, including that of plastic industries. Since plastic has a very long analytical life, it will cause environmental pollution, so studies have resorted to reusing recycled waste plastic (sustainable plastic) to produce environmentally friendly concrete (green concrete). In this research, producing environmentally friendly load-bearing concrete masonry units (blocks) was considered where five concrete mixtures were compressed at the blocks producing machine. The cement content reduced from 400 kg/m3 (B-400) to 300 kg/m3 (B-300) then to 200 kg/m3 (B-200). While (B-380) was produced using 380 kg/m3 cement and 20 kg/m3 nano-sil

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Fri Jun 25 2021
Journal Name
International Journal Of Drug Delivery Technology
Comparison among the Synthesis of Some Azomethine Derivatives by Classical and Non-classical Methods
...Show More Authors

In this time, most researchers toward about preparation of compounds according to green chemistry. This research describes the preparation of 2-fluoro-5-(substituted benzylideneamino) benzonitrile under reflux and microwave methods. Six azomethine compounds (B1-6) were synthesized by two methods under reflux and assisted microwave with the comparison between the two methods. Reflux method was prepared of azomethine (B1-6) by reaction of 5-amino-2-fluorobenzonitrile with some aldehyde derivatives with (50–100) mL of absolute ethanol and some quantity of GAA and time is limited between (2–5) hours with a yield between (60–70) percent with recrystallization for appropriate solvents. But the microwave-assisted method was synthesized of co

... Show More
View Publication Preview PDF
Publication Date
Sun Aug 30 2020
Journal Name
Journal Of Economics And Administrative Sciences
Proposing Robust IRWs Technique to Estimate Segmented Regression Model for the Bed load Transport of Tigris River with Change Point of Water Discharge Amount at Baghdad City
...Show More Authors

Segmented regression consists of several sections separated by different points of membership, showing the heterogeneity arising from the process of separating the segments within the research sample. This research is concerned with estimating the location of the change point between segments and estimating model parameters, and proposing a robust estimation method and compare it with some other methods that used in the segmented regression. One of the traditional methods (Muggeo method) has been used to find the maximum likelihood estimator in an iterative approach for the model and the change point as well. Moreover, a robust estimation method (IRW method) has used which depends on the use of the robust M-estimator technique in

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Mar 29 2021
Journal Name
Journal Of Engineering
Effluent quality assessment of sewage treatment plant using principal component analysis and cluster analysis
...Show More Authors

Sewage water is a mixture of water and solids added to water for various uses, so it needs to be treated to meet local or global standards for environmentally friendly waste production. The present study aimed to analyze the new Maaymyrh sewage treatment plant's quality parameters statistically at Hilla city. The plant is designed to serve 500,000 populations, and it is operating on a biological treatment method (Activated Sludge Process) with an average wastewater inflow of 107,000m3/day. Wastewater data were collected daily by the Mayoralty of Hilla from November 2019 to June 2020 from the influent and effluent in the (STP) new in Maaymyrh for five water quality standards, such as (BOD5), (COD), (TSS), (TP)

... Show More
View Publication Preview PDF
Crossref (3)
Crossref