Preferred Language
Articles
/
joe-2154
Effect of Cryogenic Treatment on the Properties of Low Carbon A858 Steel
...Show More Authors

This study is concerned with the effect of Deep Cryogenic Treatment (DCT) at liquid nitrogen temperature (-196 o C) on the mechanical properties and performance of low carbon steel (A858). The tests specimens were divided in to two groups, the first group was subjected to the conventional heat treatment of normalizing, and the second group was also normalized then subjected to (DCT). The results have shown that after (DCT), the Hardness, Tensile properties and the impact energy absorbed were all slightly increased. However the fatigue test showed some positive improvement in fatigue limit by 20(N/mm2 ), and the volume wear rates at different loads were significantly decreased after (DCT). The changes in microstructure due to (DCT) were clearly noticeable, the grain boundaries were no longer visible, and the Pearlite isles globalization was obvious.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Apr 14 2016
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
Study The Effect of α-amylase Inhibitors Isolated from Plant Sources on Some Mold.: Study The Effect of α-amylase Inhibitors Isolated from Plant Sources on Some Mold.
...Show More Authors

Activity test of the inhibitors purified from barley and broad beans crop proved the inhibition activity against 6 types of rots Pencillium ssp and Aspergellusflavus and Aspergillus niger and Fusarium solani and Fusarium semitectum and Mucor with three concentrations 0.1 and 0.2 and 0.3 mg/ml, where the inhibitor purified from the second peak of broad beans proved that it had a higher inhibition activity against the growth of test rots which were 53.75 and 62.5 and 78.5 and 76.25 and 84 and 18.8% respectively, at 0.3 mg/ ml followed by the first peak of the inhibitor purified from broad beans the inhibition activity were 43.75 and 50 and 62.96 and 75 and 80 and 12.5 then the inhibitor purified from barley in which the inhibition activity

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 02 2019
Journal Name
Journal Of The College Of Education For Women
Design of an Electron Gun Using two Electrod Low Aberration Immersion Lens
...Show More Authors

Abstract
A two electrode immersion electrostatic lens used in the design
of an electron gun, with small aberration, has been designed using
the finite element method (FEM). By choosing the appropriate
geometrical shape of there electrodes the potential V(r,z) and the
axial potential distribution have been computed using the FEM to
solve Laplace's equation.
The trajectory of the electron beam and the optical properties of
this lens combination of electrodes have been computed under
different magnification conditions (Zero and infinite magnification
conditions) from studying the properties of the designed electron
gun can be supplied with Abeam current of 5.7*10-6 A , electron
gun with half acceptance

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Mechanical Engineering Research And Developments
Real-time control of robotic hand by human hand at low cost
...Show More Authors

Scopus (4)
Scopus
Publication Date
Sun May 24 2026
Journal Name
Journal Of Engineering
Testing and Commissioning of a Low-Speed Wind Tunnel (LSWT) Test Section
...Show More Authors

The calibration of a low-speed wind tunnel (LSWT) test section had been made in the present work. The tunnel was designed and constructed at the Aerodynamics Lab. in the Mechanical Engineering Department/University of Baghdad. The test section design speed is 70 m/s. Frictional loses and uniformity of the flow inside the test section had been tested and calibrated based on the British standards for flow inside ducts and conduits. Pitot-static tube, boundary layer Pitot tube were the main instruments which were used in the present work to measure the flow characteristics with emphasize on the velocity uniformity and boundary layer growth along the walls of the test section. It is found that the maximum calibrated velocity for empty test sect

... Show More
View Publication
Publication Date
Thu Jan 07 2021
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Relationship of Low Maternal Vitamin D3 Level and Adverse Early Neonatal Outcomes
...Show More Authors

View Publication
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Design of six electrode Enzial electrostatic lens low aberrations for electron gun
...Show More Authors

A computerized investigation has been carried out on the design of six electrodes electrostatic lenses used in electron gun application. The Finite-Element Method (FEM) was used in the solution of Laplace equation for determine the axial potential distribution. The electron trajectory under zero magnification condition. The optical properties, spherical and chromatic aberrations, the object and image focal length and object and image position are calculated. A very good futures for the electron gun with these lenses have been computed where are a beam current of 8.7*10-7A can be supplied using cathode tip of radius 10nm.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Testing and Commissioning of a Low-Speed Wind Tunnel (LSWT) Test Section
...Show More Authors

The calibration of a low-speed wind tunnel (LSWT) test section had been made in the present work. The tunnel was designed and constructed at the Aerodynamics Lab. in the Mechanical Engineering Department/University of Baghdad. The test section design speed is 70 m/s. Frictional loses and uniformity of the flow inside the test section had been tested and calibrated based on the British standards for flow inside ducts and conduits. Pitot-static tube, boundary layer Pitot tube were the main instruments which were used in the present work to measure the flow characteristics with emphasize on the velocity uniformity and boundary layer growth along the walls of the test section. It is found that the maximum calibrated velocity for empty test s

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 30 2008
Journal Name
Al-kindy College Medical Journal
Using of Laser Therapy in the Treatment of Patients With Plantar Fasciitis
...Show More Authors

Background: planter fasciitis is a common condition
seen in adults and sport men, it is characterized by dull
pain in the heel, especially when getting up and
standing on the foot in the morning or after sitting for a
long time.
Recently low level laser therapy is used as a method of
treatment.
Objective: to evaluate the benefit of laser therapy in
treatment of planter fasciitis.
Methods: Out of twenty five patients with planter
fasciitis exposed to laser therapy. Laser used is (diode
type) given in two cessions per week for four weeks,
time for each cession is about (12 minutes).
Results: complete recovery seen in (32%) of patients,
moderate improvement in (16%), mild improvement in
(24%), no

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2007
Journal Name
Iraqi Postgraduate Medical Journal
Therapeutic evaluation of spironolactone and finasteride in the treatment of acne vulgaris
...Show More Authors

S Khalifa E, AM Sabeeh A, AN Adil A, AW Ghassan H…, 2007

View Publication
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
The Efficacy of (810 Nm) Diode Laser in Treatment of Idiopathic Epistaxis
...Show More Authors

There are many causes for epistaxis but it is mainly idiopathic in type. In Management of epistaxis there are different modality either medical or cautery(chemical or galvanic) recently laser is used in management of epistaxis. The type of laser used in current study was 810 nm diode laser. The aim of the study is to evaluate its efficiency in control of active and non active idiopathic epistaxis; The design of the study is interventional therapeutic trial. The study was performed from December 2011 to December 2012 in Al Yarmouk teaching hospital at otorhinolaryngology department. In current study the diode laser is used in different power with same exposure time in all application; The power density is measured and choose the best one

... Show More
View Publication Preview PDF