In this study, thermal characteristics of a two-phase closed heat pipe were investigated experimentally and theoretically. A two-phase closed heat pipe (copper container, Fluorocarbon FC-72 (C6F14) working fluid) was fabricated to examine its performance under the effect of input heat flux range of 250–1253 W/m2 , 70% fill charge ratio and various tilt angles. The temperature distribution along the heat pipe, input heat to evaporator section, and output heat from condenser were monitored. A comprehensive mathematical model was developed to investigate the steadystate heat transfer performance of a two-phase closed heat pipe. A steady state analytical model, is presented to determine important parameters on the design of two-phase closed heat pipe, including temperature levels and heat transfer coefficients for condenser and evaporator. The experimental and simulation results of this work are found in good agreement. The experimental boiling heat transfer coefficients were compared with existing previously reported correlations.
This research presents experimental and theoretical investigation of 15 reinforced concrete spliced and nonspliced girder models. Splices of hooked dowels and cast in place joints, with or without strengthening steel plates were used. Post-tensioning had been used to enhance the splice strength for some spliced girders. The ANSYS computer program was used for analyzing the spliced and non-spliced girders. A nonlinear three dimensional element was used to represent all test girders. The experimental results have shown that for a single span girder using steel plate connectors in the splice zone has given a sufficient continuity to resist flexural stresses in this region. The experimental results have shown that the deflection of hooked do
... Show MoreThis work is to examine the employment of curved fins to boost heat recovery in a double-pipe containment system filled with phase change material (PCM). The study utilizes CFD modeling, validated against experimental benchmarks, to evaluate how various geometric parameters of curved fins affect system performance. Findings demonstrate that adjusting the fin angular curvature from 60◦ to 180◦ yielded a 22.1 % decrease in the time required for solidification while simultaneously improving heat recovery efficiency by 32.0 %. When the fin base spacing was increased from 5 mm to 15 mm, the system showed a 14.5 % solidification time saving and a 20.9 % heat recovery improvement. Furthermore, modifying the joining angle between upper fins fro
... Show MoreThe thermal performance of indirect expansion solar assisted heat pump, IX-SAHP, was investigated experimentally under Iraqi climate. An Indirect-Solar Assisted Heat Pump system was designed, built, instrumented and tested. Experimental tests were conducted by varying the controlling parameters to investigate their effects on the thermal performance of the IX-SAHP such as cooling water flow rate, heating water flow rate, ambient temperature and solar radiation intensity. The investigation covered values of cooling water flow rate of (2, 3, 4, 5 l/min) and heating water flow rate of (2, 3, 4, 5 l/min) under meteorological condition of Baghdad from November 2014 to January 2015.
The results indicated that the performance of the IX-
... Show MoreA cantilever beam is made from composite material which is consist of (matrix: polyester) and (particles: Silicon-Carbide) with different volume fraction of particles. A force is applied at the free end of beam with different values. The experimental maximum deflection of beam which occurs at the point of the applied load is recorded. The deflection and slope of beam are analyzed by using FEM modeling. MATLAB paltform is built to assemble the equations, vector and matrix of FEM and solving the unknown variables (deflection and slope) at each node. Also ANSYS platform is used to modeling beam in finite element and solve the problem. The numerical methods are used to compare the results with the theoretical and experimental data. A good ag
... Show MoreFreshwater scarcity poses a global challenge, particularly in regions where conventional water resources are limited. Solar stills offer an economical, sustainable solution; however, their yield is limited. This study aims to evaluate a new tracking concentrated tilted tubular solar still equipped with a heat‐pipe TTSS‐HP. The novelty of the present work lies in four aspects: a novel trough U‐channel design that improves the interception of reflected solar radiation, a novel hexagonal glass cover design. A receiver formed of four‐sections, combined with a heat‐pipe and dual trough concentrators. Outdoor experiments are carried out in Baghdad, Iraq (33.27° N, 44.37° E),
The earth-air heat exchanger (EHX) has a promising potential to passively save the energy consumption of traditional air conditioning systems while maintaining a high degree of indoor comfort. The use of EHX systems for air conditioning in commercial and industrial settings offers several environmental benefits and is capable of operating in both standalone and hybrid modes. This study tests the performance and effectiveness of an EHX design in a sandy soil area in Baghdad, Iraq. The area has a climate of the subtropical semi-humid type. Ambient air temperatures and soil temperatures were recorded throughout the months of 2021. During the months of January and June, the temperatures of the inlet and outflow air at varying air veloci
... Show More