Preferred Language
Articles
/
joe-2099
Performance Evaluation of Al-Rustamiya Wastewater Treatment Plant
...Show More Authors

Al-Rustamiya sewage treatment plant (WWTP) serves the east side of Baghdad city (Rusafa) and is considered one of the largest projects.It consists of three parts (old project F0, first extension F1, and second extension F2) that treat wastewater and the
effluent is discharged into Diyala river and thus into the Tigris River. These plants are designed and constructed with an aim to manage wastewater to reachIraqi effluent standard for BOD5, COD, TSS and chloride concentrations of 40, 100, 60 and 600
mg/L respectively. The data recordedfrom March till December 2011 provided from Al-RustamiyaWWTP, were considered in this study to evaluate the performance of the plant. The results indicated that the strength of the wastewater entering the plant
varied from medium to high. The average concentrations of the effluent of BOD5, COD, TSS and chloride were within Iraqi effluent standards. The overall efficiency removalswere: For BOD5: 92.1, 90.31, and 92.96% for F0, F1, and F2 respectively COD: 88.23, 87.9, and 87.95% for F0, F1, and F2 respectively TSS: 86.98, 80.72, and 89% for F0, F1, and F2 respectively Chloride: 14.79, 15.37, and 15.31% for F0, F1, and F2 The mean value of BOD5/COD ratio of the raw wastewater was 0.67 as for typical untreated domestic wastes. The mean BOD/COD ratios of the treated sewage from F0 was 0.48, from F1 0.50 and from F2 0.38. These ratios did not confirm with the typical ratios indicating that the wastewaterneeds more treatment

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 01 2013
Journal Name
Innovative Systems Design And Engineering
Water And Alcohol Extraction Of Thyme Plant (Thymus Vulgaris) And Activity Study Against Bacteria, Tumors And Used As Anti-Oxidant In Margarine Manufacture
...Show More Authors

Isolation had been done for active substances from Thyme plant (Thymus Vulgaris) such as volatile oils, Saponins and Tannins. The percentage in form was (21.1%),(59.2%),( 9.7%) respectively. Also a study of anti-bacterial activity of extracts from Thyme using two types of pathogenic bacteria Escherichia Coli and aurous Staphylococcus showed the ability of inhibition for all different extracts by vary inhibition diameters for different active substances, concentrations and bacteria. One type of cancer cellular line used to study the effect of Thyme extracts on the growth of cells in the laboratory and thus know the specifications of extracts as anti-tumor, (L20B) cell line have been used which is mice Transformed cell Line. The possibility o

... Show More
Preview PDF
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
Estimating excess of lung risk factor of radon gas for some houses in Al-Fallujah city
...Show More Authors

Instruments for the measurements of radon, thoron and its decay
products in air are based mostly on the detection of alpha particles.
The health hazards of radon on general public are well known. In
order to understand the level and distribution of 222Rn concentrations
indoor in Al-Fallujah City; new technique was used, this technique
was three radon–thoron mixed field dosimeters is made up of a twin
chamber cylindrical system and three LR-115 type II detectors were
employed. The aim of this work was to measurement radon gas using
SSNTD technique door in in Al-Fallujah City, and estimation of
excess in cancer due to increment in radon gas. Results for samples
which are collected from January to

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Aug 12 2021
Journal Name
Applied System Innovation
The Role of Correlation in the Performance of Massive MIMO Systems
...Show More Authors

Massive multiple-input multiple-output (m-MIMO) is considered as an essential technique to meet the high data rate requirements of future sixth generation (6G) wireless communications networks. The vast majority of m-MIMO research has assumed that the channels are uncorrelated. However, this assumption seems highly idealistic. Therefore, this study investigates the m-MIMO performance when the channels are correlated and the base station employs different antenna array topologies, namely the uniform linear array (ULA) and uniform rectangular array (URA). In addition, this study develops analyses of the mean square error (MSE) and the regularized zero-forcing (RZF) precoder under imperfect channel state information (CSI) and a realist

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Dec 01 2019
Journal Name
2019 Ieee Asia-pacific Conference On Computer Science And Data Engineering (csde)
Effect of Clay Content on Performance of a Crushed Rock Mix
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
The Effect of Additives on The Performance of Hydrostatic Thrust Bearings
...Show More Authors

 

The paper is concerned with, the behavior of the hydrostatic thrust bearings lubricated with liquid-solid lubricants using Einstein viscosity formula, and taking into account the centrifugal force resulting from high speed.  Also studied is the effect of the bearing dimensions on the pressure, flow rate, load capacity, shear stress, power consumption and stiffness.

The theoretical results show an increase in load capacity by (8.3%) in the presence of solid graphite particles with concentration of (16%) by weight as compared with pure oil, with increasing shear stress.  .

In general the performance of hydrostatic thrust bearings improve for load carrying capacity, volume flow rate,

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
The Effect of Hydraulic Accumulator on the Performance of Hydraulic System
...Show More Authors

The purpose of this paper is to depict the effect of adding a hydraulic accumulator to a hydraulic system. The experimental work includes using measuring devices with interface to measure the pressure and the vibration of the system directly by computer so as to show the effect of accumulator graphically for real conditions, also the effects of hydraulic accumulator for different applications
have been tested. A simulation analysis of the hydraulic control system using MATLAB.R2010b to study was made to study the stability of the system depending on the transfer function, to estimate the effect of adding the accumulator on stability of the system. A physical simulation test was made for the hydraulic system using MATLAB to show the ef

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Mar 31 2016
Journal Name
Al-khwarizmi Engineering Journal
Experimental Study of the Performance of Compound Parabolic Concentrating Solar Collector
...Show More Authors

The design, construction and investigation of experimental study of two compound parabolic concentrators (CPCs) with tubular absorber have been presented. The performance of CPCs have been evaluated by using outdoor experimental measurements including the instantaneous thermal efficiency. The two CPCs are tested instantly by holding them on a common structure. Many tests are conducted in the present work by truncating one of them in three different levels. For each truncation the acceptance half angle (θc) was changed. Geometrically, the acceptance half angle for standard CPC is (26o). For the truncation levels for the other CPC 1, 2 and 3 the acceptance half angle were 20o, 26o and 5

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 01 2007
Journal Name
Al-khwarizmi Engineering Journal
Effects of internal Acoustic Excitation on the Improvement of Airfoil Performance
...Show More Authors

The effect of internal acoustic excitation on the leading-edge, separated boundary layers and the aerodynamic performance of NACA23015 cross section airfoil are examined as a function of excitation location with ranging frequency range (50-400) Hz of the introduced acoustic. Tests are separately conducted in two sections, open type wind tunnels at the Reynolds number of 3.3x105 for measurement at angle of attack (0, 3, 6, 9 &12) deg. and 3x104 for the visualization at angle of attack (12) deg. based on the airfoil chord. Results indicated that the excitation frequency and the excitation location are the key parameters to alter the flow properties and thus to improve the aerodynamic performance. The most effective excitation frequency

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 01 2024
Journal Name
Gazi University Journal Of Science
Effect of Natural Bitumen on the Performance of Hot Asphalt Mixture‏
...Show More Authors

For over a century, the global consumption of asphalt binder in asphalt mixture production has been substantial. In the Heet region (west of Iraq), two distinct forms of natural asphalt (NA) deposits exist: rock asphalt and sulfur spring asphalt. This study focused on using NA sourced from sulfur springs. The aim was to investigate the potential of incorporating NA into local asphalt mixtures. To achieve this, NA was heated to 163°C for varying durations. After heat treatment, laboratory tests were conducted on NA. The findings suggest that by heating NA for 20 hours, it conforms to Iraqi specifications in terms of physical properties. Furthermore, compared to conventional petroleum asphalt, treated NA showed greater

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sun Apr 30 2017
Journal Name
Journal Of Engineering
The Effect of Fin Design on Thermal Performance of Heat Sink
...Show More Authors

      An experimental and computational study is conducted to analyze the thermal performance of heat sinks and to pick up more profound information in this imperative field in the electronic cooling. One important approach to improve the heat transfer on the air-side of the heat exchanger is to adjust the fin geometry. Experiments are conducted to explore the impact of the changing of diverse operational and geometrical parameters on the heat sink thermal
performance. The working fluid used is air. Operational parameters includes: air Reynolds number (from 23597 to 3848.9) and heat flux (from 3954 to 38357 W/m
2 ). Conformational parameters includes: change the direction of air flow and the area of conduct

... Show More
View Publication Preview PDF