An experimental investigation of natural convection heat transfer from an isothermal horizontal,vertical and inclined heated square flat plates with and without circular hole, were carried out in two cases, perforated plates without an impermeable adiabatic hole "open core" and perforated plates with an impermeable adiabatic hole "closed core" by adiabatic plug. The experiments covered the laminar region with a range of Rayleih number of (1.11x106 ≤RaLo≤4.39x106 ), at Prandtle number (Pr=0.7). Practical experiments have been done with variable inclination angles from horizon (Ф=0o ,45o,90o,135oand 180o),facing upward (0o≤Ф<90o), and downward (90o
≤Ф<180o). The results showed that the temperature gradient increases while the thermal boundary layer thickness decreases when Grashof number and perforation ratio (m) increase . The temperature gradient for inclined position facing upward is less than facing downward,while the thermal boundary layer thickness is greater. The temperature gradient decreases while the thermal boundary layer thickness increases for perforated plates with an adiabatic core as compared with perforated plates without an adiabatic core. The value of average Nusselt number increases with increasing perforation ratio, and Grashof number for all specimens with and without an adiabatic core, also increases by increase in inclination of plates approaching the higher value at vertical position (Ф=90o
), then decreases with increasing inclination of plates till horizontal position (Ф=180o). The average Nusselt number values for perforated plates with an adiabatic core are lower than for perforated plates without an adiabatic core for all perforation ratios. Maximum heat transfer rate occurs at perforated plate with perforation ratio of (m=0.1) without adiabatic core for vertical position (Ф=90o), at a range of Grashof number (1.576x106≤GrLo≤6.292x106 ), while the rate of heat transfer decreases with increasing perforation ratio for plates with and without adiabatic core for decrease in heat transfer rate area. The rate of heat transfer for
perforated plates with circular hole is more than for perforated plates with square hole at the same perforation ratios (m=0.1,0.16,0.24 and 0.36). It found that the lack of core flow decreases the overall heat transfer rate by (6.477%) . There was a good agreement for the experimental present work results compared with other pervious results .
Maintenance of hospital buildings and its management are regarded as an important subject which needs attention because hospital buildings are service institutions which are very important to a society, requiring the search for the best procedure to develop maintenance in hospitals. The research is aimed to determine an equation to estimate the annual maintenance cost for public hospital. To achieve this aim, Al-Sader City Hospital maintenance system in Al-Najaf province has been studied with its main elements through survey of data, records and reports relating to maintenance during the years of the study 2008-2014 and to identify the strengths, weaknesses, opportunities and threat points in the current system through Swat analysi
... Show MoreThe research work was conducted to investigate the effect of oral administration of water extract of black pepper at doses of (1, 5) mg/kg body weight for two weeks daily by determining the genotoxic effect (mitotic index), evaluation of immunological effect (IgG, IgM, IgA, C3, C4) and measuring fertility hormones (follicles stimulation hormone/FSH, lutenising hormone/LH) levels with histopathological examinations of female albino swiss mice ovaries in comparison with control (normal saline). A clear effect in increasing mitotic activity was reveled for both doses in comparison with control. Results also showed a significant increase in the value of the all immunological parameters at both doses in comparison with control. Also obvious rais
... Show MoreBackground: Large amounts of oily wastewater and its derivatives are discharged annually from several industries to the environment. Objective: The present study aims to investigate the ability to remove oil content and turbidity from real oily wastewater discharged from the wet oil's unit (West Qurna 1-Crude Oil Location/ Basra-Iraq) by using an innovated electrocoagulation reactor containing concentric aluminum tubes in a monopolar mode. Methods: The influences of the operational variables (current density (1.77-7.07 mA/cm2) and electrolysis time (10-40 min)) were studied using response surface methodology (RSM) and Minitab-17 statistical program. The agitation speed was taken as 200 rpm. Energy and electrodes consumption had been studi
... Show MoreIn the present research, the electrical properties which included the ac-conductivity (σac), loss tangent of dielectric (tan δ) and real dielectric constant (ε’) are studied for nano polycarbonate in different pressures and frequencies as a function of temperature these properties were studied at selective temperature gradients which are (RT-50-100-150-250)°C. The results of the study showed that the values of dielectric constant and dissipation factor increase with increasing pressure and temperature and decreases by increasing frequency. And the results of electrical conductivity showed that it increases with increasing temperature, pressure and frequency.
Thermal energy storage is an important component in energy units to decrease the gap between energy supply and demand. Free convection and the locations of the tubes carrying the heat-transfer fluid (HTF) have a significant influence on both the energy discharging potential and the buoyancy effect during the solidification mode. In the present study, the impact of the tube position was examined during the discharging process. Liquid-fraction evolution and energy removal rate with thermo-fluid contour profiles were used to examine the performance of the unit. Heat exchanger tubes are proposed with different numbers and positions in the unit for various cases including uniform and non-uniform tubes distribution. The results show that
... Show MoreIn recent years, there has been expanding development in the vehicular part and the number of vehicles moving on the roads in all the sections of the country. Arabic vehicle number plate identification based on image processing is a dynamic area of this work; this technique is used for security purposes such as tracking of stolen cars and access control to restricted areas. The License Plate Recognition System (LPRS) exploits a digital camera to capture vehicle plate numbers is used as input to the proposed recognition system. Basically, the proposed system consists of three phases, vehicle license plate localization, character segmentation, and character recognition, the
... Show MoreTwenty bacterial isolates were identified as Staphylococcus aureus collected from wounds and catheters related infections. A capsulated S. aureus isolate was chosen after performing serum soft agar test, for this study Neutropenic mice were challenged with capsulated S. aureus ,and the effect of G-CSF with or without moxifloxacin was studied. The results indicated that the addition of G-CSF to moxifloxacin therapy have a synergistic effect in the killing of the bacteria, while when each G-CSF and moxifloxacin were used seperately have a similar effect on bacterial killing. It was found that the moxifloxacin has the same activity as G_CSF but is less costly than the latter one.
Background: Health professionals have a crucial role in promotion, support and management of breastfeeding. To be effective in this effort, the clinician should focus on the issue from the preconception stage through pregnancy and delivery, and continue in subsequent infant care. Aim of the study: to assess the effectiveness of the UNICEF/WHO 40-hour of breast feeding training through the assess breastfeeding knowledge and attitudes of the health profession staff before and after training course.
The fluctuation and expansion ratios have been studied for cylindrical gas-solid fluidized columns by using air as fluidizing medium and Paracetamol as the bed material. The variables were the column diameter (0.0762, 0.15, and 0.18 m), static bed height (0.05, 0.07, and 0.09 m), and air velocity to several times of minimum fluidization velocity. The results showed that both the fluctuation and expansion ratios had a direct relation with air velocity and an inverse one with column diameter and static bed height. A good agreement was between the experimental results and the calculated values by using the correlation equations from the literature.