The differential protection of power transformers appears to be more difficult than any type of protection for any other part or element in a power system. Such difficulties arise from the existence of the magnetizing inrush phenomenon. Therefore, it is necessary to recognize between inrush current and the current arise from internal faults. In this paper, two approaches based on wavelet packet transform (WPT) and S-transform (ST) are applied to recognize different types of currents following in the transformer. In WPT approach, the selection of optimal mother wavelet and the optimal number of resolution is carried out using minimum description length (MDL) criteria before taking the decision for the extraction features from the WPT tree. In ST approach,
the spectral energy index and the standard deviation (STD) are calculated from the S-matrix obtained by discrete S-transform. The two approaches are tested for generating a trip signal and disconnecting the transformer supply experimentally using 1KVA, 220/110V, 50Hz, ∆ / Y threephase transformer. The experimental results show that the trip signal is initiated faster in WPT approach while the transformer is disconnected from the supply after a delay of 10-15msec in the
two approaches due to computer interface and the relay circuit used.
Although the events of September 2001 marked the United States' employment of solid forces in its direct comprehensive strategy to counter terrorist organizations and any other challenges to US national security, the United States did not lose sight of the importance of the cultural variable. The cultural variable is the United States' most important instrument of soft power in ensuring its dominance of the international system and promoting its global project. France viewed US soft power as a threat to its own civilizational pattern. Therefore, France considers culture to be an inherent component of its national personality and a cornerstone of its international standing as a major force. Additionally, the US-French political and economic
... Show MoreThis paper presents an improved technique on Ant Colony Optimization (ACO) algorithm. The procedure is applied on Single Machine with Infinite Bus (SMIB) system with power system stabilizer (PSS) at three different loading regimes. The simulations are made by using MATLAB software. The results show that by using Improved Ant Colony Optimization (IACO) the system will give better performance with less number of iterations as it compared with a previous modification on ACO. In addition, the probability of selecting the arc depends on the best ant performance and the evaporation rate.
Static Synchronous Series Compensator (SSSC) is a well known device for effectively regulating the active power flow in a power system. In this paper, the SSSC linearized power flow equations are incorporated into Newton-Raphson algorithm in a MATLAB written program to investigate the control of active poweer flow and the transient stability of a five bus and a thirty bus IEEE test systems, during abnormal conduction (three phase fault near buses). A comparison of the results obtained for the base case without SSSC and with it to investigate the effectiveness of the device on both of the active power flow and the transient stability.
Thermal management has become a major issue in the latest high performance computing machines because high CPU temperatures result in inefficient performance and decreased hardware life span. In this work, the cooling performance of a finned metal foam heat sink (FMFHS) was examined. The pore density values of tested copper metal foam (CMF) samples with different values of PPI 5, 10 and 20, with a constant porosity of 90%. For reference, these samples were measured by a conventional Aluminum plate-fin heat sink (CHS). The work was performed under experimental conditions in which air directed over the heat sink surface at air velocities (2.5, 3.0 and 3.5 m/s). The environmental temperature was fixed at 27 °C. Findings
... Show MoreThis study uses load factor and loss factor to determine the power losses of the electrical feeders. An approach is presented to calculate the power losses in the distribution system. The feeder’s technical data and daily operation recorded data are used to calculate and analyze power losses.
This paper presents more realistic method for calculating the power losses based on load and loss factors instead of the traditional methods of calculating the power losses that uses the RMS value of the load current which not consider the load varying with respect to the time. Eight 11kV feeders are taken as a case study for our work to calculate load factor, loss factor and power losses. Four of them (F40, F42, F43 and F
... Show MoreMicrobial Desalination Cell (MDC) is capable of desalinating seawater, producing electrical power and treating wastewater. Previously, chemical cathodes were used, which were application restrictions due to operational expenses are quite high, low levels of long-term viability and high toxicity. A pure oxygen cathode was using, external resistance 50 and 150 k Ω were studied with two concentrations of NaCl in the desalination chamber 15-25 g/L which represents the concentration of brackish water and sea water. The highest energy productivity was obtained, which amounted to 44 and 46 mW/m3, and the maximum limit for desalination of saline water was (31% and 26%) for each of 25 g / L and 15 g / L, respectively, when using an ex
... Show MoreEight patients (3 male and 5 female) were treated in this study by Endovenous Laser Ablation (EVLA); Mathematical models are proposed to estimate the applied laser power and to assess the recovery period. The estimations of the applied laser power and recovery period in these models will be depended mainly on the diameter of the incompetent vein. In addition, Excel Program was utilized to find the proposed models. A 1470 nm diode laser up to 15W continuous power (CW) was used in the treatment of venous ulcers by EVLA procedure. Following up by duplex ultrasound was started in the 1st week after the first session until the vein is completely closed. The present study concluded that the relationship both between
... Show MoreIn this paper, we investigate the connection between the hierarchical models and the power prior distribution in quantile regression (QReg). Under specific quantile, we develop an expression for the power parameter ( ) to calibrate the power prior distribution for quantile regression to a corresponding hierarchical model. In addition, we estimate the relation between the and the quantile level via hierarchical model. Our proposed methodology is illustrated with real data example.