Air stripping for removal of Trichloroethylene (TCE), Chloroform (CF) and Dichloromethane (DCM) from water were studied in a bubble column (0.073 m inside dia. and 1.08 m height with several sampling ports). The contaminated water was prepared from deionized water and VOCs. The presence of VOCs in feed solution was single, binary or ternary components. They were diluted to the concentrations ranged between 50 mg/l to 250 mg/l. The experiments were carried out in batch experiments which regard the bubble column as stirred tank and only gas was bubbled through stationary liquid. In this case transient measurements of VOC concentration in the liquid phase and the measured concentration profiles were modeled by bubble aeration model (BAM) to fit the experimental data fairly well. The results from batch experiments show that the removal efficiency of VOCs increases with increasing gas flow rate or gas holdup. It is found a pH=10 give the best removal rate, but all experiments were adjusted at pH=8 which allow to study other operating conditions. TCE is being removed faster than the other two components for all systems and a single component was removed faster than binary or ternary system. The KLa values were evaluated by fitting the BAM to the experimental data. It is found that KLa increased with increasing gas flow rate and TCE exhibits the highest KLa values.
The determination of river pollution impact on the performance of water treatment plants is achieved by two main objectives. The first is to study raw and treated water qualities and comparing them with standards and the second is to evaluate the treatment plants efficiency. The analyzed data were those water quality parameters in relation to physical, chemical and bacteriological characteristics for river water and produced water by seven water treatment plants located on Tigris River passing through Baghdad City.
The results of this study indicated that all raw water characteristic are within the surface water standards established by Iraqi and USA criteria except Bacterial Counts.
Tigris River water is of good quality to be trea
The monitoring of lotic ecosystems is an important issue. This study investigated the total petroleum hydrocarbons (THP) in the Tigris River within Baghdad City, Iraq, which is considered the ultimate water supply source of the city. The study included measurement of THP concentrations, distribution, and origins of total petroleum hydrocarbons (TPHs) in various matrices (water, sediment, and macrophyte) in Tigris River within Baghdad City, in addition to some environmental factors during two seasons (dry and wet) for October 2020 to April 2021. The sampling was collected from three sites along the river. Thirteen compounds were identified in the current investigation from total petroleum h
Applications of quantitative methods, which had been explicit attention during previous period (the last two centuries) is the method of application sales man or traveling salesman method. According to this interest by the actual need for a lot of the production sectors and companies that distribute their products, whether locally made or the imported for customers or other industry sectors where most of the productive sectors and companies distributed always aspired to (increase profits, imports, the production quantity, quantity of exports. etc. ...) this is the part of the other hand, want to behave during the process of distribution routes that achieve the best or the least or most appropriate.
... Show MoreThis study was conducted to detect the relationship between organic content in the sediment of Rivers Tigris and Diyala, at two locations south of Baghdad, with some environmental factors and the benthic invertebrates and values of diversity indices. Monthly samples collected from the area for the period November 2007 to October 2008. Results showed differences in the physical and chemical characteristics of the two sites, Where the annual average in Tigris and Diyala were respectively for: water temperature (19, 20) C°, pH (8, 8), dissolved oxygen (4, 8) mg / l , Biochemical oxygen Demand BOD5 (3,44 ) mg/l, TDS (632,1585) mg / l, TSS (42, 44) mg / l, turbidity (28,74) NTU, and total hardness as CaCO3 (485,823) mg / l ,Sulfat
... Show MoreAbstract
The purpose of this research is to develop a proposed framework for achieving the Integration of the Target Cost and Resource Consumption Accounting Techniques and to show the role they play in reducing products costs and supporting the competitive advantage to cope with contemporary changes. To achieve this goal, the researchers followed the analytical method using the statistical questionnaire as a means of collecting data from the research sample include accounting, administrative, technical, engineering staffs and others. The research sample consists of (56) individuals and for the purpose of conducting statistical analysis of the data and testing hypotheses, the statistical program (SPSS) wa
... Show MoreThe present paper deals with experimental investigation of the performance of air cooled split air conditioner, with evaporative water mist pre cooling to increase the cooling capacity and reduce the consumption power under hot and dry climate. This investigation considers how the performance can be enhanced by using water mist to pre-cool ambient air entering the condensers by adiabatic cooling process which depends on the ambient air wet bulb temperature; as well the condensing temperature and condensing pressure will be decreased accordingly. So the cooling capacity would be increased and consumption power would be decreased, consequently the energy ratio, EER would be improved. The performance of air cooled air conditioner with water
... Show MoreOrganic soil is problematic soils in geotechnical engineering due to its properties, as it is characterized by high compressibility and low bearing capacity. Therefore, several geotechnical techniques tried to stabilize and improve this soil type. In this study, sodium silicate was used to stabilize sand dune columns. The best sodium silicate concentration (9%) was used, and the stabilized sand dune columns were cured for seven days. The results for this soil were extracted using a numerical analysis program (Plaxis 3D, 2020).In the case of studying the effect of (L/D) (where ‘’L” and ‘’D’’ length and diameter of sand dune columns) of a single column of sand dunes stabilized with sodium silicate with a diff
... Show MoreThe study was conducted in the fields of the Department of Horticulture and Landscaping/College of Agriculture/University of Al-Qadisiyah/Al-Nouriah district - for the 2019-2020 agricultural season to study the effect of spraying with organic sulfur and hydrogen peroxide on the growth and yield of onions, Allium cepa L, where the study included two factors: the first factor was spraying organic sulfur at concentration (0, 2)., 4 ml. L-1) and symbol S1, S2, S3 and the second factor spraying with hydrogen peroxide at a concentration (0, 2, 4 ml. L-1) and symbolized by B1, B2, B3 and the interaction between them. A factorial experiment was conducted according to the randomized complete b
In this study, the stable isotop 18O and 2H has been used to investigate the interaction of surface water (SW), and groundwater (GW) in Al-Taji district/ Northern Baghdad for two seasons (March and August 2022). 16 Samples were collected from water resources in the Al-Taji district (Tigris channel, Tigris River, and groundwater), in each season water samples from 8 Tigris channel, 5 drilled wells, and 3 Tigris River were taken for the analysis of the isotopes 18O and 2H. The average analysis results of 18O and 2H in the Tigris channel, Tigris River, and groundwater were found to be -3.435‰ and -18.6094‰, -2.07167‰ and -17.81‰, -4.125‰ and -34.707‰ respectively. The results, generally, show a comparable range of isotope c
... Show More