Gypsum Plaster is an important building materials, and because of the availabilty of its raw materials. In this research the effect of various additives on the properties of plaster was studied , like Polyvinyl Acetate, Furfural, Fumed Silica at different rate of addition and two types of fibers, Carbon Fiber and Polypropylene Fiber to the plaster at a different volumetric rate. It was found that after analysis of the results the use of Furfural as an additive to plaster by 2.5% is the optimum ratio of addition to that it improved the flexural Strength by 3.18%.
When using Polyvinyl Acetate it was found that the ratio of the additive 2% is the optimum ratio of addition to the plaster, because it improved the value of the flexural strength by a rate of 3.44% of the value of standards fraction of the mixture of reference. It was noted that the optimum ratio for the addition of Fumed Silica to the plaster is the ratio of 1%, because this ratio of addition increases the flexural strength by 15.26%. For the addition of Carbon Fiber to the plaster it was found that the volumetric ratio of the additive 0.5% is the percentage of perfect accessory after taking into account cost and quality which gives an increase in Flexural Strength by rate of 41.43% .When using Polypropylene Fiber it was found that the optimum percentage ratio of addition 1.5%, where this ratio increases flexural strength by a rate of 23.67% . When using the mixture (PVCF), which contains 2% of Poly vinyl Acetate and 0.5% as a volumetric rate of the carbon fiber to the plaster, increases the value of Flexural Strength by a rate 62.92%. After analyzing the results for all mixtures it was found that the mixture (PVCF) is the best one to satisfy the aim of the research which is to get the best structural properties specially flexural strength for gypsum beams.
A set newly complexes with the general formula [M(L)Cl2] are resulting from the reaction of a new schiff base ligand [Ethyl (6R,7R)-7-((E)-2-((2-ethoxy-2- oxoethoxy)imino)-2-(2-(((E)-4-nitrobenzylidene) amino) thiazol -4- yl) acetamido) -8- oxo -3- vinyl -5- thia -1-aza bicyclo [4. 2.0] oct -2- ene -2- carboxylate] (L). This ligand was derived from the reaction of the two substances 4-nitrobenzaldehyde and precursor (P). Reaction the ligand with metal ions M= Mn(II), Co(II), Ni(II), Cu(II) and Cd(II) afforded new complexes which are characterized by FT-IR and Electronic Spectra. These measurements indicate that the complexes have a tetrahedral geometry. The Penicillin-Binding Protein 3 (PBP3) of Staphylococcus aureus and the target protein
... Show MoreThe present study aimed to investigate the anatomy, histology, and immunohistochemistry of parathyroid gland in two Iraqi mammals (Weasel, Herpestes javanicus and Long-ear hedgehog, Hemiechinus auritus) as a comparative study. A total of (20) animal for each species were used in the present study. Animals collected were immediately anesthesia and dissected to get the parathyroid gland. Methods of Humason and Bancroft and Stevens were employed for histological techniques. Different stains were used (Hematoxylin- Eosin stain-(H & E), Periodic Acid Schiff stain-(PAS), Azan stain, and Methyl Blue stain-(MB)) for staining the histological sections. Anti-calcitonin, code140778 marker used for immune-histochemical study. Results of the present stu
... Show MoreBackground: Dental implants act as infrastructure for fixed restoration to look like as a natural tooth. Osseointegration is a biological events and considered as a base for success of dental implant. The aim of this study is to evaluate the bond strength between bone and Ti implant coated with mixture of nano hydroxyapatite-chitosan-collagen compared with Ti implants coated with nano hydroxyapatite implanted in rabbit tibia, after different period of implantation time (two and six weeks) by torque removal test. Material and methods: 36 screws of commercially pure titanium; 8mm in length and 3mm diameter , 18 screws coated with mixture of nano hydroxyapatite-chitosan-collagen and18 screws coated with nano hydroxyapatite by dip coating. St
... Show MoreBackground: Breast cancer is the commonest type of malignancy worldwide and in Iraq. It is a serious disease that affects the general health and cause systemic changes that affect the physical and chemical properties of saliva leading to adverse effects on oral health. This study was conducted toassess the tumor marker CA15-3 and selected elements in saliva and their relation to oral health status among breast cancer patients compared to control group. Materials and Methods: The total sample consisted of 60 women aged 35-45 years. 30 women were newly diagnosed with breast cancer before taking any treatment and surgery (study group) and 30 women without clinical signs and symptoms of breast cancer as a control group. Dental caries was record
... Show MoreBackground and Aim. Coronary artery disease (CAD) is a major risk factor for the progression to heart failure (HF), which is associated with an increase in left ventricular volume (LVV). This study aims to measure ventricular function and myocardial perfusion imaging markers of the left side of the heart, which can be performed with injection of a 99mTc at stress and rest by using single-photonemission-computed-tomography (SPECT). Subject and methods. The study included 121 patients with CAD, comprising 53 females and 68 males with ages between 25 to 88 years and 265 healthy subjects comprising 84 males and 181 females. All patients and healthy subjects volunteered to participate in this study. They were classified according to
... Show MoreEach Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show More