Preferred Language
Articles
/
joe-1971
Performance Assessment of Pile Models Chemically Grouted by Low-Pressure Injection Laboratory Device for Improving Loose Sand
...Show More Authors

The complexity and partially defined nature of jet grouting make it hard to predict the performance of grouted piles. So the trials of cement injection at a location with similar soil properties as the erecting site are necessary to assess the performance of the grouted piles. Nevertheless, instead of executing trial-injected piles at the pilot site, which wastes money, time, and effort, the laboratory cement injection devices are essential alternatives for evaluating soil injection ability. This study assesses the performance of a low-pressure laboratory grouting device by improving loose sandy soil injected using binders formed of Silica Fume (SF) as a chemical admixture (10% of Ordinary Portland Cement OPC mass) to different (W/C) water/cement ratios (by mass materials) mixes. Trial grouting processes were executed to optimize the practical ranges of the operating factors of the laboratory device to obtain consistent grouted model pile samples. The paper examined the relations of the binders' W/C ratios with the densities, elasticity modulus (E), and Uniaxial Compression Stress (UCS) of the grouted piles. The investigation results show that as the binder W/C ratio rises, the grouted pile samples' dry density, E, and UCS values decrease. For the binder injected with a W/C ratio of one and 10% SF additive by weight of cement mass, the highest values of the grouted pile for density, E, and UCS were about 2.32 g/cm3, 23 MPa, and 2000 MPa, respectively. The UCS of the grouted pile proved that the binders' W/C ratios and the SF addition have an evident effect on the investigated factors of the grouted piles.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Mar 01 2012
Journal Name
Journal Of Economics And Administrative Sciences
Comparison study of Information Criteria to determine the order of Autoregressive models
...Show More Authors

بهذا البحث نقارن معاييرالمعلومات التقليدية (AIC , SIC, HQ , FPE ) مع معيارمعلومات الانحراف المحور (MDIC) المستعملة لتحديد رتبة انموذج الانحدارالذاتي (AR) للعملية التي تولد البيانات,باستعمال المحاكاة وذلك بتوليد بيانات من عدة نماذج للأنحدارالذاتي,عندما خضوع حد الخطأ للتوزيع الطبيعي بقيم مختلفة لمعلماته

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 31 2021
Journal Name
Political Sciences Journal
Role of the executive in federal experiences: a study of selected models
...Show More Authors

Receipt date:06/23/2020 accepted date:7/15/2020 Publication date:12/31/2021

Creative Commons License This work is licensed under a Creative Commons Attribution 4.0 International License

The executive authority differs from one country to another, as it differs from a federal state to another according to the nature of the applied political systems, so this research focused on federal states according to their political systems, then going into the details of the executive authority and its role In the federal states by referring to the four federal experiments

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 02 2026
Journal Name
Philosophy Journal
Philosophy of Civilization Read and critique and analysis of the selected models
...Show More Authors

View Publication
Publication Date
Fri Jul 26 2013
Journal Name
Environmental Geochemistry And Health
Assessment of sulfurous springs in the west of Iraq for balneotherapy, drinking, irrigation and aquaculture purposes
...Show More Authors

View Publication
Crossref (18)
Crossref
Publication Date
Thu Mar 01 2018
Journal Name
2018 Tenth International Conference On Advanced Computational Intelligence (icaci)
On low-level control strategies of lower extremity exoskeletons with power augmentation
...Show More Authors

View Publication
Scopus (9)
Crossref (6)
Scopus Crossref
Publication Date
Sat Feb 02 2019
Journal Name
Journal Of The College Of Education For Women
Design of an Electron Gun Using two Electrod Low Aberration Immersion Lens
...Show More Authors

Abstract
A two electrode immersion electrostatic lens used in the design
of an electron gun, with small aberration, has been designed using
the finite element method (FEM). By choosing the appropriate
geometrical shape of there electrodes the potential V(r,z) and the
axial potential distribution have been computed using the FEM to
solve Laplace's equation.
The trajectory of the electron beam and the optical properties of
this lens combination of electrodes have been computed under
different magnification conditions (Zero and infinite magnification
conditions) from studying the properties of the designed electron
gun can be supplied with Abeam current of 5.7*10-6 A , electron
gun with half acceptance

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 02 2026
Journal Name
Journal Of Engineering
Testing and Commissioning of a Low-Speed Wind Tunnel (LSWT) Test Section
...Show More Authors

The calibration of a low-speed wind tunnel (LSWT) test section had been made in the present work. The tunnel was designed and constructed at the Aerodynamics Lab. in the Mechanical Engineering Department/University of Baghdad. The test section design speed is 70 m/s. Frictional loses and uniformity of the flow inside the test section had been tested and calibrated based on the British standards for flow inside ducts and conduits. Pitot-static tube, boundary layer Pitot tube were the main instruments which were used in the present work to measure the flow characteristics with emphasize on the velocity uniformity and boundary layer growth along the walls of the test section. It is found that the maximum calibrated velocity for empty test sect

... Show More
View Publication
Publication Date
Sun Mar 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Mass Transfer Coefficient During Cathodic Protection of Low Carbon Steel in Seawater
...Show More Authors

The aim of this research is to calculate mass transfer coefficient, kd, during cathodic protection of low carbon steel in neutral seawater (3.5% W/V NaCl in distilled water with pH = 7). Two types of cathodic protection were used:

First: Sacrificial anode cathodic protection (SACP) were a pipeline of steel carrying seawater  using zinc as a sacrificial anode and with variable temperatures ranged (0 – 45oC) and volumetric flow rate ranged (5 – 900 lit/hr). It was found that the kd increases with increasing temperature and volumetric flow rate of seawater, where kd ranged (0.24×10-6 – 41.6×10-6 m/s).

Second: Impressed current cathodic pr

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Low Carbon Steel in Sulfuric Acid Using Polyvinyl Alcohol
...Show More Authors

The inhibitive power of Polyvinyl Alcohol (PVA) was investigated toward the corrosion of carbon steel in 0.2N H2SO4 solution in the temperature range of 30-60˚C and PVA concentration range of 150-2000 ppm.

   The corrosion rate was measured using both the weight loss and the electrochemical techniques. The weight loss results showed that PVA could serve as a corrosion inhibitor but its inhibition power was found to be low for the corrosion of carbon steel in the acidic media. Electrochemical analysis of the corrosion process of carbon steel in an electrochemical corrosion cell was investigated using 3-Electrode corrosion cell. Polarization technique was used for carbon steel corrosion in 0.2N H

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Testing and Commissioning of a Low-Speed Wind Tunnel (LSWT) Test Section
...Show More Authors

The calibration of a low-speed wind tunnel (LSWT) test section had been made in the present work. The tunnel was designed and constructed at the Aerodynamics Lab. in the Mechanical Engineering Department/University of Baghdad. The test section design speed is 70 m/s. Frictional loses and uniformity of the flow inside the test section had been tested and calibrated based on the British standards for flow inside ducts and conduits. Pitot-static tube, boundary layer Pitot tube were the main instruments which were used in the present work to measure the flow characteristics with emphasize on the velocity uniformity and boundary layer growth along the walls of the test section. It is found that the maximum calibrated velocity for empty test s

... Show More
View Publication Preview PDF
Crossref (1)
Crossref