Preferred Language
Articles
/
joe-1971
Performance Assessment of Pile Models Chemically Grouted by Low-Pressure Injection Laboratory Device for Improving Loose Sand
...Show More Authors

The complexity and partially defined nature of jet grouting make it hard to predict the performance of grouted piles. So the trials of cement injection at a location with similar soil properties as the erecting site are necessary to assess the performance of the grouted piles. Nevertheless, instead of executing trial-injected piles at the pilot site, which wastes money, time, and effort, the laboratory cement injection devices are essential alternatives for evaluating soil injection ability. This study assesses the performance of a low-pressure laboratory grouting device by improving loose sandy soil injected using binders formed of Silica Fume (SF) as a chemical admixture (10% of Ordinary Portland Cement OPC mass) to different (W/C) water/cement ratios (by mass materials) mixes. Trial grouting processes were executed to optimize the practical ranges of the operating factors of the laboratory device to obtain consistent grouted model pile samples. The paper examined the relations of the binders' W/C ratios with the densities, elasticity modulus (E), and Uniaxial Compression Stress (UCS) of the grouted piles. The investigation results show that as the binder W/C ratio rises, the grouted pile samples' dry density, E, and UCS values decrease. For the binder injected with a W/C ratio of one and 10% SF additive by weight of cement mass, the highest values of the grouted pile for density, E, and UCS were about 2.32 g/cm3, 23 MPa, and 2000 MPa, respectively. The UCS of the grouted pile proved that the binders' W/C ratios and the SF addition have an evident effect on the investigated factors of the grouted piles.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Feb 10 2019
Journal Name
Journal Of The College Of Education For Women
The Effect of Using Reciprocal Teaching on Improving College Students' Achievement in Reading Comprehension
...Show More Authors

Reciprocal Teaching is an interactive method that is used to improve reading comprehension. Using this teaching strategy, teachers and students take turns leading discussions regarding sections of text using the four strategies: predicting, questioning, clarifying and summarizing. This study is an attempt to investigate the effect of using reciprocal teaching on improving female college students' achievement in reading comprehension. To fulfill the aim of the study, the researcher has adopted two null hypotheses: first, there is no significant difference between the achievement of students' who practice the reciprocal teaching technique and that of students who do not practice it. Second, there is no statistically significant difference

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 31 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Study the Effect of Using Microwave Radiation and H-Donors on Improving Heavy Oil
...Show More Authors

The present research has investigated the effect of microwave energy on improving the flow properties of heavy crude oil. The fragmentation of crude oil molecules was carried out with and without using 1 and 10 wt. % concentration of various types of H-donors like tetralin, cyclohexane, and naphtha.  Microwave power of 320, 385, and 540 W and radiation time 1-9 min, and temperature were studied. The kinematic viscosity and asphaltene content were measured for evaluation the improving of heavy crude oil.

   Results show that viscosity of crude oil decreased with increase H-donor concentration, a maximum percentage of viscosity reduction was10.63 % for tetralin at 6 min radiation time, while 8.67%, and 7.34% for cycl

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 01 2019
Journal Name
Journal Of Economics And Administrative Sciences
apply Six Sigma in improving the quality of projects added expert system )Applied research(
...Show More Authors

Construction projects need methods and techniques to ensure the level of quality and commensurate with the level required and documented in the project contract. The quality of the project is affected by the quality of the inputs and accompanying procedures in the construction of the project.

Al-Rumaitha residential project found that the quality of the concrete for the ceilings in the research sample (the roof of the third floor of buildings A25 and A26) and (roof of the second floor of buildings A27, A28, A29, A30, A31, A32 and A33) and roof of buildings A15 and A16 A19)) is not the required quality level.

The idea of the research came after the need to improve the performance o

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri May 01 2020
Journal Name
Environmental Technology & Innovation
Environmental remediation of synthetic leachate produced from sanitary landfills using low-cost composite sorbent
...Show More Authors

Scopus (37)
Crossref (32)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Materials Today: Proceedings
Evaluating the individual, dual usage of (TGP) and (SF) additives on improving gypsum characteristics
...Show More Authors

View Publication
Scopus (11)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sat Dec 31 2022
Journal Name
Journal Of Economics And Administrative Sciences
Improving Customer Value Through the Integral of Techniques Quality Function Deployment and Value Engineering
...Show More Authors

Health service institutions suffer from challenges resulting from the great changes that our world is witnessing today.  This has affected the value that these institutions add to the patient.

This research aims to identify the effect of integrating each of the techniques of QFD and value engineering for the health services provided to the patient to improve the value for him and thus obtain his satisfaction, which is reflected in the reputation of the surveyed hospitals. To achieve this, the descriptive analytical method was used, and a questionnaire was designed to collect the necessary data, which represents a measure of this research. The questionnaire was distri

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 01 2020
Journal Name
Journal Of Constructional Steel Research
Demountable steel-concrete composite beam with full-interaction and low degree of shear connection
...Show More Authors

It is suitable to use precast steel-concrete composite beams to quickly assemble a bridge or a building, particularly in isolated regions where cast-in-situ concrete is not a practical option. If steel-concrete composite beams are designed to allow demountability, they can also be extremely useful in the aftermath of natural disasters, such as earthquakes or flooding, to replace damaged infrastructure. Furthermore, rapid replacement of slabs is extremely beneficial in case of severe deterioration due to long-term stressors such as fatigue or corrosion. The only way to rapidly assemble and disassemble a steel-concrete composite structure is to use demountable shear connectors to connect/disconnect the steel beams to/from the concrete slab. I

... Show More
View Publication
Scopus (47)
Crossref (37)
Scopus Clarivate Crossref
Publication Date
Sat Mar 31 2018
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Comparison between the Product-Refill and the Equalization Oxygen Pressure Swing Adsorption Processes
...Show More Authors

This work presents a design for a pressure swing adsorption process (PSA) to separate oxygen from air with approximately 95% purity, suitable for different numbers of columns and arrangements. The product refill PSA process was found to perform 33% better (weight of zeolite required or productivity) than the pressure equalization process. The design is based on the adsorption equilibrium of a binary mixture of O2 and N2 for two of the most commonly used adsorbents, 5A & 13X, and extension from a single column approach. Zeolite 13X was found to perform 6% better than zeolite 5A. The most effective variables were determined to be the adsorption step time and the operational pressure. Increasing the adsorption step

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
Assessing the efficiency Economic performance of the diyala General company for electrical industries for the Period (2000-2010)
...Show More Authors


     Facing industrial companies many pressures and challenges due to rapid changes in the business environment of contemporary, which requires them to do their performance look more inclusive rather than limiting performance evaluation on the financial perspective in spite of its importance, prompting companies to rethink their reality competitive through the adoption of methodologies and new philosophies to manage competitiveness of total quality management, and re-engineering of production processes, and knowledge management,... etc., as This study framework cognitive and practical "to evaluate the performance of a company Diyala General Electric Industries and how to rehabilitate

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Determination of Water-Soluble Vitamins in Iraqi Honey Bee and Compare with Others Types by High –Performance Liquid Chromatography
...Show More Authors

High-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was

... Show More
View Publication Preview PDF
Crossref (4)
Crossref