Preferred Language
Articles
/
joe-191
Determination of Mono-crystalline Silicon Photovoltaic Module Parameters Using Three Different Methods
...Show More Authors

For modeling a photovoltaic module, it is necessary to calculate the basic parameters which control the current-voltage characteristic curves, that is not provided by the manufacturer. Generally, for mono crystalline silicon module, the shunt resistance is generally high, and it is neglected in this model. In this study, three methods are presented for four parameters model. Explicit simplified method based on an analytical solution, slope method based on manufacturer data, and iterative method based on a numerical resolution. The results obtained for these methods were compared with experimental measured data. The iterative method was more accurate than the other two methods but more complexity. The average deviation of the iterative method  not more than 5% of current- voltage values with the corresponding experimental data. The average deviation for the other two method 9.3% for slope method and 7.9% for simplifies method.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Feb 26 2021
Journal Name
Iraqi Journal Of Science
Determination the Optimum Conditions of the Activity and Stability of Lipase Extracted from Sunflower Germinated Seeds
...Show More Authors

The present study was conducted to determine the optimum conditions required for lipase enzyme activity extracted from germinated sunflower seeds, including temperature, pH, agitation, time of incubation, enzyme concentration, substrate type, and concentrations of mineral salts and EDTA. Optimum pH, temperature and time of incubation required for lipase stability were also determined. The results showede optimum lipase activity (3.251U/ml) wasund at 30 ÌŠC and pH 7 after 20 minutes of incubation when using 1 ml lipase enzyme with 0.02 ml of CaCl2 (10 mM) at 100 rpm of agitation and in the presence of olive oil as the substrate for enzyme reaction. EDTA appeared to have inhibitory effects, while Ca+2 and Mg+2 have stimulatory effec

... Show More
View Publication
Scopus (8)
Crossref (3)
Scopus Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Geological Journal
Integrating Petrophysical and Geomechanical Rock Properties for Determination of Fracability of the Iraqi Tight Oil Reservoir
...Show More Authors

Tight oil reservoirs have been a concerned of the oil industry due to their substantial influence on oil production. Due to their poor permeability, numerous problems are encountered while producing from tight reservoirs. Petrophysical and geomechanical rock properties are essential for understanding and assessing the fracability of reservoirs, especially tight reservoirs, to enhance permeability. In this study, Saadi B reservoir in Halfaya Iraqi oil field is considered as the main tight reservoir. Petrophysical and geomechanical properties have been estimated using full-set well logs for a vertical well that penetrates Saadi reservoir and validated with support of diagnostic fracture injection test data employing standard equations

... Show More
View Publication
Scopus (7)
Scopus Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Comparison between Linear and Non-linear ANN Models for Predicting Water Quality Parameters at Tigris River
...Show More Authors

In this research, Artificial Neural Networks (ANNs) technique was applied in an attempt to predict the water levels and some of the water quality parameters at Tigris River in Wasit Government for five different sites. These predictions are useful in the planning, management, evaluation of the water resources in the area. Spatial data along a river system or area at different locations in a catchment area usually have missing measurements, hence an accurate prediction. model to fill these missing values is essential.
The selected sites for water quality data prediction were Sewera, Numania , Kut u/s, Kut d/s, Garaf observation sites. In these five sites models were built for prediction of the water level and water quality parameters.

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Mar 16 2021
Journal Name
International Journal For Computational Methods In Engineering Science And Mechanics
Determination of time-dependent coefficients in moving boundary problems under nonlocal and heat moment observations
...Show More Authors

View Publication
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Methods And Objects Of Chemical Analysis
Derivative Spectrophotometric Determination For Simultaneous Estimation Of Isoniazid And Ciprofloxacin In Mixture And Pharmaceutical Formulation
...Show More Authors

A simple analytical method was used in the present work for the simultaneous quantification of Ciprofloxacin and Isoniazid in pharmaceutical preparations. UV-Visible spectrophotometry has been applied to quantify these compounds in pure and mixture solutions using the first-order derivative method. The method depends on the first derivative spectrophotometry using zero-cross, peak to baseline, peak to peak and peak area measurements. Good linearity was shown in the concentration range of 2 to 24 μg∙mL-1 for Ciprofloxacin and 2 to 22 μg∙mL-1 for Isoniazid in the mixture, and the correlation coefficients were 0.9990 and 0.9989 respectively using peak area mode. The limits of detection (LOD) and limits of quantification (LOQ) wer

... Show More
View Publication Preview PDF
Scopus (16)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
Determination of Copper and Lead and Study their Poisonous Effects in Drinking Water in Baghdad
...Show More Authors

The objective of this study is to determine the concentration of copper and lead (mg/L) in drinking water by using absorption spectrophotometic and Atomic Absorption spectrophotometric method from different area in Baghdad and with different intervals , The results show that the concentration of copper and Lead ( mgL) in tap water which remains motionless in plumbing system for following periods one hours, 3 hours, 6 hours, 12 hours, 24 hours, 7 days and 14 days are (1 , 2.2 , 4 , 5.3 , 7.5 , 10 and 16 mgL copper ) & ( 0.3, 0.5 , 0.8 , 1 , 2.5 , 3 , 3.8 mg /L lead ) respectively .from these results its clear that high levels of copper & Lead occur if tap water comes in contact with copper - lead plumbing and copper lead -containing fix

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Oct 29 2023
Journal Name
Iraqi National Journal Of Nursing Specialties
Determination of Job Stress among Nurses in Cardiac Surgical Intensive Care Units in Baghdad City
...Show More Authors

Objective: The study aimed to determine the sources and level of job stress experienced by nurses who were
working in intensive care units, and to find-out the relationship between work-related stress and some variables
such as age, gender, educational level, marital status, and years of experience in cardiac surgical intensive care
unit.
Metl]odo]ogy: A descriptive study was conducted on nurses working in the cardiosurgical intensive care units in
Baghdad hospitals. The study sample was selected purposively and consisted of (60) nurses who were working
in cardiosurgical intensive care units in Baghdad city (Ibm Al-Betar Hospital for Cardiac Surgery, Ibn A1-Nafis
Hospital for Cardiovascular Diseases, and the Iraqi Ce

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Bismuth(III) with Arsenazo(III) Reagent in Water samples and Veterinary Preparation
...Show More Authors

A simple , sensitive and accurate spectrophotometric method for the trace determination of bismuth (III) has been developed .This method is based on the reaction of bismuth (III) with arsenazo(III) in acid solution (pH=1.9) to form a blue water soluble complex which exhibits maximum absorption at 612nm .Beer's law is obeyed over the concentration range of 2-85 ?g bismuth (III) in a final volume of 20 mL( i.e. 0.1 – 4.25?g.mL-1) with a correlation coefficient of (0.9981) and molar absorptivity 1.9×104 L.mol-1.cm-1 . The limit of detection (LOD) and the limit of quantification (LOQ) are 0.0633 and 0.0847 ?g.mL-1 , respectively . Under optimum conditions,the stoichiometry of the reaction between bismuth (III) and arsenazo(III) r

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Apr 28 2025
Journal Name
Chemical Papers
New chemiluminometric method for the determination of azithromycin in a continuous flow injection analysis system
...Show More Authors

A novel analytical method is developed for the determination of azithromycin. The method utilizes continuous flow injection analysis to enhance the chemiluminescence system of luminol, H2O2, and Cr(III). The method demonstrated a linear dynamic range of 0.001–100 mmol L-1 with a high correlation coefficient (r) of 0.9978, and 0.001–150 mmol L-1 with a correlation coefficient (r) of 0.9769 for the chemiluminescence emission versus azithromycin concentration. The limit of detection (L.O.D.) of the method was found to be 18.725 ng.50 µL−1 based on the stepwise dilution method for the lowest concentration within the linear dynamic range of the calibration graph. The relative standard deviation (R.S.D. %) for n = 6 was less than 1.2%

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Egyptian Journal Of Chemistry
First- and Second-Derivative Spectrophotometry for Simultaneous Determination of lorazepam and clonazepam in pharmaceutical formulations
...Show More Authors

The present study describes employing zero-, 1st - and 2nd -order derivative spectrophotometric methods have been developed for determination of lorazepam (LORA) and clonazepam (CLON) in commercially available tablets. LORA was determined by means of 1st (D1), 2nd (D2) derivative spectrophotometric techniques using zero cross, peak height, and Peak area. D1 used for the determination of CLON by using zero cross and peak height while D2 (zero cross) was used for the determination of CLON. The method was established to be linear in concentration containing different ratios of LORA and CLON range of (20-200 mg/L) and (5-35 mg/L) at wavelength range (250 -370 nm), (210-370nm) respectively. The proposed techniques are highly sensitive, precise a

... Show More
Preview PDF