Preferred Language
Articles
/
joe-1837
Comparative Reliability Analysis between Horizontal-Vertical-Diagonal Code and Code with Crosstalk Avoidance and Error Correction for NoC Interconnects
...Show More Authors

Ensuring reliable data transmission in Network on Chip (NoC) is one of the most challenging tasks, especially in noisy environments. As crosstalk, interference, and radiation were increased with manufacturers' increasing tendency to reduce the area, increase the frequencies, and reduce the voltages.  So many Error Control Codes (ECC) were proposed with different error detection and correction capacities and various degrees of complexity. Code with Crosstalk Avoidance and Error Correction (CCAEC) for network-on-chip interconnects uses simple parity check bits as the main technique to get high error correction capacity. Per this work, this coding scheme corrects up to 12 random errors, representing a high correction capacity compared with many other code schemes. This candidate has high correction capability but with a high codeword size. In this work, the CCAEC code is compared to another well-known code scheme called Horizontal-Vertical-Diagonal (HVD) error detecting and correcting code through reliability analysis by deriving a new accurate mathematical model for the probability of residual error Pres for both code schemes and confirming it by simulation results for both schemes. The results showed that the HVD code could correct all single, double, and triple errors and failed to correct only 3.3 % of states of quadric errors. In comparison, the CCAEC code can correct a single error and fails in 1.5%, 7.2%, and 16.4% cases of double, triple, and quadric errors, respectively. As a result, the HVD has better reliability than CCAEC and has lower overhead; making it a promising coding scheme to handle the reliability issues for NoC.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Nov 01 2014
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
Debulking of Keloid Combined with Intralesional Injection of 5-Flurouracil and Triamcinolone versus Intralesional Injection of 5-Flurouracil and Triamcinolone
...Show More Authors

KE Sharquie, AA Noaimi, MR Al-Karhi, Journal of Cosmetics, Dermatological Sciences and Applications, 2014 - Cited by 2

View Publication
Publication Date
Sun Dec 25 2016
Journal Name
University Of Baghdad / College Of Education For Pure Sciences / Ibn-al-‎haitham/ Chemistry Department
Synthesis and Spectroscopic Studies and ‎Biological Activity of New Ligands ‎Containing S,N,O Donor Atoms with their ‎Metal Complexes
...Show More Authors

The 3-aminoacetophenone and 4-aminoantipyrine were used as ‎precursors to prepare new six ligands. The three new ligands (L1,L2 ‎and L3) were synthesis by reacting one mole of 3-aminoacetophenone ‎with one mole of (Acetyl chloride), (benzoyl chloride), (4-‎methoxybenzoyl chloride) and ammonium thiocyanat in acetone as a ‎solvent, they are:-‎ L1 (AAA) =[N-(3-acetylphenylcarbamothioyl)acetamide]‎ L2 (BAA) =[N-(3-acetylphenylcarbamothioyl)benzamide]‎ L3 (MAA) =[N-(3-acetylphenylcarbamothioyl)-4-methoxy benzamide]‎ Also three new derivatives of 4-aminoantipyrine were synthesis by ‎reacting one mole of 4-aminoantipyrine with one mole of (Acetyl ‎chloride), (benzoyl chloride), (4-methoxybenzoyl chloride) and ‎ammonium thio

... Show More
Publication Date
Mon Sep 09 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Association of hsCRP and Serum Kalirin Levels with the Development and Severity of Premature Coronary Artery Disease in Iraqi Patients
...Show More Authors

Background: Coronary artery disease (CAD) is a major contributor to morbidity and mortality worldwide. Early-onset CAD, also known as PCAD, is a severe form of CAD associated with high mortality and a poor prognosis. Early diagnosis is crucial to reducing complications. While hsCRP is an established biomarker for CAD, kalirin is a potential novel biomarker due to its role in promoting smooth muscle proliferation and endothelial dysfunction. Objective: To evaluate the relationship between serum kalirin and hsCRP levels with the presence and severity of PCAD and to compare the diagnostic value of both biomarkers. Method: The study recruited 92 participants into two groups: the PCAD group (46) included patients with confirmed CAD by an

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Sat Dec 11 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Association of Age, Parity and Body mass Index with Hemoglobin and Serum Ferritin Levels in Pregnant Women in Baghdad City
...Show More Authors

Hemogloin (Hb) and serum ferritin levels are used to assess anemia in pregnancy. Some studies referred to the influence of maternal age, body mass index (BMI) and parity on Hb and serum ferritin levels. The study aimed to examine the possible association of maternal Hb and serum ferritin with maternal age, parity, and BMI in a sample of pregnant women in Baghdad.

 Ninety healthy pregnant women, grouped in three equal groups according to the pregnancy trimester, and thirty apparently healthy non-pregnant women from Baghdad were enrolled in this observational study.  Blood and serum samples were obtained for the estimation of Hb and serum ferritin levels.

The pooled data of participants showed a n

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Ibn Al-haitham Jour.for Pure & Appl.sci.
Study of IL-33 and IL-1R4 in Iraqi Rheumatoid Arthritis Female Patient's with and without Dyslipidemia Prone to Atherosclerosis
...Show More Authors

This study is planned to find relationship between interleukin-33 (IL-33) with its receptor interleukin-1 receptor 4 (IL-1R4), and assurance IL-33/IL-1R4 proportion as biomarker to atherosclerosisin rheumatoid arthritis (RA) Iraqi female’s patients with and without dyslipidemia. This study was attempted at Baghdad Teaching Hospital included 60 female’s patients with RA that were isolated into: 30 patients with dyslipidemia(G2), 30 patients without dyslipidemia(G3) and 30 individuals as control group (G1). Patients were experiencing treatment by methortexiene medication, analyzed by rheumatoid factor (RF) and erythrocyte sedimentation rate (ESR) tests. All patients and control groups age ranged from (30-55) years. The results show an inc

... Show More
Publication Date
Sun Apr 06 2008
Journal Name
Diyala Journal For Pure Science
Preliminary Test Bayesian –Shrunken Estimators for the Mean of Normal Distribution with Known Variance
...Show More Authors

Publication Date
Wed Jul 08 2015
Journal Name
The Iraqi Postgraduate Medical Journal
Simultaneous Complete Intracorneal Ring Implantation with Intrapocket Collagen Cross- Linking for Treatment of Keratoconus
...Show More Authors

BACKGROUND: Keratoconus is a progressive non inflammatory bilateral (usually asymmetric) ectatic corneal disease characterized by paraxial stromal thinning ,weakening that lead to corneal surface distortion ,vision loss primarily from irregular astigmatism and myopia and secondly from corneal scar. OBJECTIVE: To evaluate visual and refractive outcomes after intracorneal continuous ring (ICCR) implantation combined with intrapocket corneal collagen cross linking in patient with keratoconus. Setting: Eye Specialty Private Hospital, Baghdad, Iraq. METHODS: This study assessed the results of implantation of Myoring ICCR combined with CXL in 40 eyes with KC. Outcome measures include UDVA,CDVA(spectacle correction),refraction, complications and s

... Show More
Preview PDF
Publication Date
Fri Nov 04 2022
Journal Name
Journal Of Optics
Coreless optical fiber for hemoglobin (HB) sensing with bilayer based on surface plasmon resonance
...Show More Authors

In this work, an optical fiber biomedical sensor for detecting the ratio of the hemoglobin in the blood is presented. A surface plasmon resonance (SPR)-based coreless optical fiber was developed and implemented using single- and multi-mode optical fibers. The sensor is also utilized to evaluate refractive indices and concentrations of hemoglobin in blood samples, with 40 nm thickness of (20 nm Au and 20 nm Ag) to increase the sensitivity. It is found in practice that when the sensitive refractive index increases, the resonant wavelength increases due to the decrease in energy.

View Publication Preview PDF
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Tue Jan 14 2025
Journal Name
South Eastern European Journal Of Public Health
Deep learning-based threat Intelligence system for IoT Network in Compliance With IEEE Standard
...Show More Authors

The continuous advancement in the use of the IoT has greatly transformed industries, though at the same time it has made the IoT network vulnerable to highly advanced cybercrimes. There are several limitations with traditional security measures for IoT; the protection of distributed and adaptive IoT systems requires new approaches. This research presents novel threat intelligence for IoT networks based on deep learning, which maintains compliance with IEEE standards. Interweaving artificial intelligence with standardization frameworks is the goal of the study and, thus, improves the identification, protection, and reduction of cyber threats impacting IoT environments. The study is systematic and begins by examining IoT-specific thre

... Show More
View Publication
Crossref
Publication Date
Tue Jun 10 2025
Journal Name
Steel And Composite Structures
Flexural behaviour of prefabricated demountable composite beams with LockBolt shear connectors for accelerated construction
...Show More Authors

To promote sustainable steel-concrete composite structures, it is essential to develop special shear connectors that facilitate accelerated construction and deconstruction. A lockbolt demountable shear connector (LBDSC) was recently proposed. While the LBDSC has been evaluated using horizontal and vertical (standard) push-out tests, it is essential to further assess the disassembly mechanism and the positive flexural performance of prefabricated demountable composite beams (PDCBs) under both serviceability and ultimate limit states. Two full-scale test specimens of PDCBs with LBDSC were designed with partial shear connections and assessed using a three or four-point load beam setup under both cyclic and static monotonic loading conditions.

... Show More
Scopus (2)
Scopus