When a vehicle is left parked in the sun for an extended period, the gathered heat causes damage to several interiors within the cabin and causes discomfort for people and animals left inside the car. In the present work, the effect of the orientation of a parked white minibus on temperature distribution and cooling load calculation is studied experimentally in an open environment. Two different cases were studied facing south and facing east. For several hours, the temperature inside the car cabin had been monitored and measured at five separate locations. The cooling load calculations are carried out based on the experimental measurements. The results show that the overheating of parked cars always happens as a result of the radiation load especially when a car has a large surface glass area. Also, the ambient load is directly proportional to the ambient temperature, and the total load related directly to radiation load reaches the maximum value of 2358.1 W at 3:00 pm for 1st case and 2118.3 W at 11:00 am for 2nd case which shows an increase of 11.32 %. Thus, these results emphasized the fact that the orientation of the parked car may considerably affect the temperature distribution and the cooling load of the car cabin. Also, the study may be considered an essential step in designing any assisted ventilation or auxiliary air conditioning system that may enhance the car cabin conditions even while the car’s engine was off (parked automobile).
Heat is one of the most energy forms emitted to atmosphere by industrial processes. Water is considered to be the best material to reduce heat energy since its available in nature in abundance and has the ability to absorb heat efficiently. Cooling towers are ideal alternatives to re-cool hot water instead of throwing it especially in places that lack natural water resources or when there are environmental precautions because water with high temperature would be harmful to the ecosystem when it recycled to natural resources such as rivers and lakes. Also, cooling towers considered economically feasible when using west water. This paper interests with hydraulic characteristics of a counter flow wet cooling tower which was investigated experi
... Show MoreIn this paper, preliminary test Shrinkage estimator have been considered for estimating the shape parameter α of pareto distribution when the scale parameter equal to the smallest loss and when a prior estimate α0 of α is available as initial value from the past experiences or from quaintance cases. The proposed estimator is shown to have a smaller mean squared error in a region around α0 when comparison with usual and existing estimators.
A Survey Study Of A Sample Of The Public Of Baghdad Governorate
The current study aimed to identify the most prominent psychological and behavioral repercussions of the exposure of the elderly to the news of the Corona pandemic and to determine the mechanisms of their exposure. On an intended sample on both sides of (Al-Karkh and Al-Rasafa) and the simple random sample was adopted to choose the place of distribution of the questionnaire and the intentional sample.
The research concluded several results, most TV news is still a primary source of information and that most of the sample move between stations to see more information about the pandemic and that the presentation of views confuses the elderly ،There
... Show MoreThe present research has investigated the effect of microwave energy on improving the flow properties of heavy crude oil. The fragmentation of crude oil molecules was carried out with and without using 1 and 10 wt. % concentration of various types of H-donors like tetralin, cyclohexane, and naphtha. Microwave power of 320, 385, and 540 W and radiation time 1-9 min, and temperature were studied. The kinematic viscosity and asphaltene content were measured for evaluation the improving of heavy crude oil.
Results show that viscosity of crude oil decreased with increase H-donor concentration, a maximum percentage of viscosity reduction was10.63 % for tetralin at 6 min radiation time, while 8.67%, and 7.34% for cycl
... Show MoreThe improvement of the mechanical soil characteristics of jet grouting technique is very attractive. The jet grouted soil cement columns in soft is a complicated issue because it depends on a number of factors such as, soil nature, mixture, influence among soil and grouting materials, jetting force of nozzle, jet grouting and water flow rate, rotation and lifting speed. This paper discusses the estimation of shear strength parameters of soil-cement column (soilcrete) in soft clayey soil based on the relationships between the unconfined compressive and split tensile strength for the soilcrete and the effect of the jet grouting and water pressure in the values of cohesion and internal f
This book presents the problem of tooth decay due to bacteria Streptococcus mutans one of methods of treatment using 3 extracts of S. persica (miswak) (aqueous, acetone and methanol) and prove its effectiveness and its impact on the gtf (B, C, and D) genes that code the glucosyltransferase (Gtf) enzymes that cause decay membrane compared to the usual means used for the prevention of tooth decay
The arrival of Russian President Vladimir Putin to power in the Russian Federation is an important factor in delineating a new approach to Russian policy towards regions that have great strategic importance affecting its national security. Therefore, NATO's progress eastward towards these regions prompts Russia to delineate a new strategy to confront this progress as well as preserving its control in the near neighboring regions represented by the countries of Eastern Europe, especially after the changes that occurred in those regions following the color revolutions that swept the region, such as the first application of this Russian policy in 2014, through the annexation of Crimea, and the latest military operations in Ukraine i
... Show More