Preferred Language
Articles
/
joe-180
Buckling Loads and Effective Length Factor for Non-Prismatic Columns
...Show More Authors

Based on a finite element analysis using Matlab coding, eigenvalue problem has been formulated and solved for the buckling analysis of non-prismatic columns. Different numbers of elements per column length have been used to assess the rate of convergence for the model. Then the proposed model has been used to determine the critical buckling load factor () for the idealized supported columns based on the comparison of their buckling loads with the corresponding hinge supported columns . Finally in this study the critical buckling factor () under end force (P) increases by about 3.71% with the tapered ratio increment of 10% for different end supported columns and the relationship between normalized critical load and slenderness ratio was generalized.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jun 08 2023
Journal Name
Iraqi Journal Of Laser
PDF The effect of nanoelectrodes number and length on enhancing the THz photomixer performance
...Show More Authors

Abstract: Despite the distinct features of the continuous wave (CW) Terahertz (THz) emitter using photomixing technique, it suffers from the relatively low radiation output power. Therefore, one of effective ways to improve the photomixer emitter performance was using nanodimensions electrodes inside the optical active region of the device. Due to the nanodimension sizes and good electrical conductivity of silver nanowires (Ag-NWs), they have been exploited as THz emitter electrodes. The excited surface plasmon polariton waves (SPPs) on the surface of nanowire enhances the incident excitation signal. Therefore, the photomixer based Ag-NW compared to conventional one significantly exhibits higher THz output signal. In thi

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Radioactivity and annual effective dose in some types of drug
...Show More Authors

The aim of this research is to know danger of radioactive isotopes
that are found in samples of drugs traded in Iraqi markets. The
samples are Iraqi Amoxicillin, English Amoxicillin, UAE
Amoxicillin, Indian Amoxicillin, Iraqi Paracetamol, English
Paracetamol, UAE Paracetamol and Indian Paracetamol. By high
purity germanium the activity of the following isotopes 40K, 214Pb,
228Ac and 137Cs is measured and the specific activity was used to
calculate the annual effective dose. Then the calculated annual
effective dose values are compared with the allowable annual
effective dose values of each part of digestive channel. This research
concluded that the measured annual effective dose values are not
dangerous.<

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Oct 01 2024
Journal Name
Heliyon
Exploring nanobioceramics in wound healing as effective and economical alternatives
...Show More Authors

View Publication
Scopus (49)
Crossref (44)
Scopus Crossref
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Calculation the number buildup factor of cylindrical samples for Brass, Copper & lead
...Show More Authors

The buildup factor of cylindrical samples (shields) for Brass, Copper & lead (Brass, Cu, Pb (was studied, where buildup factor were calculated with thickness between (0-12) m.f.p. for Co60 and Cs137sources with activities (30) & (41) MBq respectively , using scintillation detector NaI(T?) with (3"×3")volume .The results shows increases of buildup factor for low atomic number(Z) samples where the energy of radiation source was constant, also shows increases of buildup factor with decreases the energy of radiation source. An empirical equation was obtained using Matlab7 program this equation have agreements with most obtained data for 96%.

View Publication Preview PDF
Crossref
Publication Date
Sun Jun 12 2016
Journal Name
Baghdad Science Journal
Measurement of Photon Buildup Factor for Samples of Iraqi Carbon Black Material
...Show More Authors

The buildup factor was measured after irradiating Iraq carbon black powder using each of and sources respectively, using mixing ratios 40% & 50% for thickness range . The results showed that the buildup factor depends on energy and has limited dependence on the mixing ratio. The QIFT program succeeded accenting for the experimental results even for expected values more than 4 m.f.p outside the thickness range.

View Publication Preview PDF
Crossref
Publication Date
Tue Dec 30 2014
Journal Name
International Journal Of Medicine And Pharmaceutical Sciences (ijmps)
YIELDS CALCULATIONS FOR POSITRON EMISSION TOMOGRAPHY (PET) FOR NON-STANDARD RADIONUCLIDE
...Show More Authors

The PET scans provide images that pinpoint the anatomic location of abnormal metabolic activity within the body. A radionuclide suitable for labeling a wide range of radiopharmaceuticals for positron emission tomography imaging is used also for local therapy of tumors. Among the possible methods for cyclotron production of radionuclide used in PET. We investigate the proton irradiation to produce the standard radionuclide (15O, 11C,1 3N, 18F) and some non-standard Radionuclide (76Br,124I,60Cu,66Ga,86Y and 89Zr). The total integral yield based on the main published and approved experimental results of excitation functions were calculated.

Preview PDF
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
An Experimental Analysis of Embankment on Stone Columns
...Show More Authors

When embankment is constructed on very soft soil, special construction methods are adopted. One of the techniques is a piled embankment. Piled (stone columns) embankments provide an economic and effective solution to the problem of constructing embankments over soft soils. This method can reduce settlements, construction time and cost. Stone columns provide an effective improvement method for soft soils under light structures such as rail or road embankments. The present work investigates the behavior of the embankment models resting on soft soil reinforced with stone columns. Model tests were performed with different spacing distances between stone columns and two lengths to diameter ratios of the stone columns, in addition to different

... Show More
View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Thu Jun 01 2017
Journal Name
Nuclear Physics A
Alpha-cluster preformation factor within cluster-formation model for odd-A and odd–odd heavy nuclei
...Show More Authors

View Publication
Scopus (58)
Crossref (59)
Scopus Clarivate Crossref
Publication Date
Sun Mar 13 2011
Journal Name
Baghdad Science Journal
The mucosal and systemic immune status for diabetic and non-diabetic Dentialvcolar infected patients
...Show More Authors

From a group of 60 patients with dentoalveolar infections among which 10 were diabetic and 10 non-diabetic were elected as test group as well as 10 normal subjects as control group. Six Staphylococcus aureus and Streptococcus anginousus were diagnosed in the first and second group of the patients the immune status of the patients and control subject were tested by pathogen specific antibody titre, neotrophil NBT reduction phagocytosis and leukocyte inhibition LIF. Diabetic patients with dentoalveolar infection shows decreased specific antibody titers, subnormal neutrophil NBT phagocytic % as well as non significant LIF % in comparison non diabetic reveal high specific antibody titers against , high neutrophil NBT% and significant LIF% re

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
The study of thermal description for non-thermal plasma needle system
...Show More Authors

Cold plasma is a relatively low temperature gas, so this feature enables us to use cold plasma to treat thermally sensitive materials including polymers and biologic tissues. In this research, the non-thermal plasma system is designed with diameter (3 mm, 10 mm) Argon at atmospheric pressure as well as to be suitable for use in medical and biotechnological applications.
The thermal description of this system was studied and we observed the effect of the diameter of the plasma needle on the plasma, when the plasma needle slot is increased the plasma temperature decrease, as well as the effect of the voltages applied to the temperature of the plasma, where the temperature increasing with increasing the applied voltage . Results showed t

... Show More
View Publication Preview PDF
Crossref (2)
Crossref