Preferred Language
Articles
/
joe-1783
Experimental Evaluation of PV Panel Efficiency Using Evaporative Cooling Integrated with Water Spraying
...Show More Authors

In this work, an inventive photovoltaic evaporative cooling (PV/EC) hybrid system was constructed and experimentally investigated. The PV/EC hybrid system has the prosperous advantage of producing electrical energy and cooling the PV panel besides providing cooled-humid air. Two cooling techniques were utilized: backside evaporative cooling (case #1) and combined backside evaporative cooling with a front-side water spray technique (case #2). The water spraying on the front side of the PV panel is intermittent to minimize water and power consumption depending on the PV panel temperature. In addition, two pad thicknesses of 5 cm and 10 cm were investigated at three different water flow rates of 1, 2, and 3 lpm. In Case #1, the evaporative cooling decreased the temperature of the PV panel by about 15 ℃ related to the uncooled PV panel for both pad thicknesses. While case #2 showed a more significant temperature drop for PV panel by about 27 ℃  and 29.7 ℃ for pad thicknesses of 5 cm and 10 cm, respectively. Compared to the uncooled PV panel, the cooled panel had a distinct enhancement in performance. The efficiency of the PV panel in case #1 was augmented by 5.7% with 50 mm pad thickness and 8.4% for 100 mm pad thickness. Case #2 revealed more improvement in the efficiency by 9% for 5 cm and up to 20% for 10 cm pad thickness. The PV panel electric power was augmented by 7.3% and 13.8% for 2 and 3 lpm water flow rates, respectively. Compared to the flow rate of 1 lpm. The open voltage circuit improved by 4.1% and 9.4% for cases #1 and #2, respectively. The higher air temperature drop was about 11.4 ℃ for case #2 at 10 cm pad thickness.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Mar 30 2021
Journal Name
Scientific Review Engineering And Environmental Studies (srees)
Testing the performance of a solar energy cooling system in Baghdad city
...Show More Authors

Renewable energy resources have become a promissory alternative to overcome the problems related to atmospheric pollution and limited sources of fossil fuel energy. The technologies in the field of renewable energy are used also to improve the ventilation and cooling in buildings by using the solar chimney and heat exchanger. This study addresses the design, construction and testing of a cooling system by using the above two techniques. The aim was to study the effects of weather conditions on the efficiency of this system which was installed in Baghdad for April and May 2020. The common weather in these months is hot in Baghdad. The test room of the design which has a size of 1 m3 was situated to face the geographical south. The te

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Mon Apr 06 2020
Journal Name
Asian Journal Of Civil Engineering
Integrated project delivery (IPD) method with BIM to improve the project performance: a case study in the Republic of Iraq
...Show More Authors

View Publication
Scopus (22)
Crossref (23)
Scopus Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Experimental and Numerical Analysis of Laser Surface Melting by Using Enthalpy Method
...Show More Authors
Abstract<p>In this study, experimental and numerical applied of heat distribution due to pulsed Nd: YAG laser surface melting. Experimental side was consists of laser parameters are, pulse duration1.3<italic>ms</italic>, wavelength 1064nm, laser energies 1.5, 2. 6 and 4.3 J, laser beam diameter is 0.6 mm and spot diameter 0.78 mm was applied a low carbon steel type St37 with a dimension 10, 10, 3 mm, length, width and thickness respectively. Numerical analysis side consist of a mathematical model and calculating a thermal cycle by using equation in the enthalpy method applied to determine the cooling rate in fusion zone. The simulation by using the enthalpy method, applied on conduction heat transfer </p> ... Show More
View Publication Preview PDF
Scopus (7)
Crossref (4)
Scopus Crossref
Publication Date
Fri Sep 30 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Using Different Surfactants to Increase Oil Recovery of Rumaila Field (Experimental Work)
...Show More Authors

Enhanced oil recovery is used in many mature oil reservoirs to increase the oil recovery factor. Surfactant flooding has recently gained interest again. To create micro emulsions at the interface between crude oil and water, surfactant flooding is the injection of surfactants (and co-surfactants) into the reservoir, thus achieving very low interfacial tension, which consequently assists mobilize the trapped oil.

In this study a flooding system, which has been  manufactured and described at high pressure. The flooding processes included oil, water and surfactants. 15 core holders has been prepared at first stage of the experiment and  filled with washed sand grains 80-500 mm and then packing the sand to obtain sand packs

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 01 2017
Journal Name
International Journal Of Science And Research (ijsr)
Performance Evaluation of the Organic Matter Removal Efficiency in Wastewater Treatment Plants; Case study Al- Diwaniyah WWTP in Iraq
...Show More Authors

This study aims to assess the removal efficiency andestablish the BOD5 and COD statisticalcorrelation of the sewage flowing in Al-Diwaniyah wastewater treatment plant in Iraq during the study period (2005-2016). The strength of the influent wastewater entering the plant varied from medium to high in strength. High concentrations of BOD5 and COD in the effluent were obtained due to the poor performance of the plant. This was observed from the BOD5 /COD ratios that did not confirm with the typical ratios for the treated sewage. To improve the performance of this plant, regression equations for BOD5 and COD removal percentages were suggested which can be used to facilitate evaluation of liquid waste and optimal control process. The equations

... Show More
Publication Date
Tue Dec 01 2009
Journal Name
Journal Of Economics And Administrative Sciences
Evaluation The Efficiency And Effectiveness of The Iraq stock Exchange -An Empirical Study From July 2004 to March 2008–
...Show More Authors

 The aim of this study was to provide an overall assessment to the efficiency of the Iraq stocks exchanges (ISE) through specifying well –known models .First, Fama's efficient market hypothesis as a contrary concept to the random walk hypothesis, was performed and it has been found that ISE follows the random process, so the price of the shares can't be predicated on the basis of past information. Second,we use a multifactor model, which so named multiple regression, to explore the link between ISE  and the main economic indicators. our empirical analysis finds that every weak associations exists between major ISE measures and main economic indicators.

View Publication Preview PDF
Crossref
Publication Date
Thu May 31 2012
Journal Name
Journal Of Baghdad College Dentistry
An evaluation of water absorption of Giomer in comparison to other resin-based restorative materials
...Show More Authors

Background: Polymeric composites have been widely used as dental restorative materials. A fundamental knowledge and understanding of the behavior of these materials in the oral cavity is essential to improve their properties and performance. The goal of this study was to measure water sorption of four composite resins containing different filler and resin matrix contents. Materials and method: Resin composite specimens giomer (Beautifil II) Filtek™ P90, Filtek™ Z350 XT, and Tetric N Ceram were prepared in a cylindrical mould of 3mm thickness and 6mm diameter (n=10) and light cured . All specimens placed in silica-gel desiccators at 37˚C for seven days, a constant weight was obtained. All samples were immersed in deionized distill

... Show More
Publication Date
Fri Apr 29 2022
Journal Name
Iraqi Journal Of Agricultural Sciences
EFFECT OF SUPPLEMENTARY IRRIGATION SYSTEM ON WHEAT PRODUCTION EFFICIENCY USING A STOCHASTIC FRONTIER ANALYSIS
...Show More Authors

This study was aimed to director wheat production's technical efficiency grown under two irrigation systems(fixed and pivot sprinkler irrigation systems)using random border analysis.Samples were collected randomly from267farmers from Salah Al-Din Governorate/Iraq.The samples were divided into two groups;187farmers used a pivot sprinkler irrigation system with three categories of possession(80,60and120dunums),while the other group used a fixed sprinkler irrigation system with four categories of possession(40,30,20and10dunums).Transcendent production function was used to study the effect of production factors on wheat yield. The results indicated that the mechanization work and the amount of added irrigation water increased by 1% whil

... Show More
View Publication
Scopus (6)
Crossref (4)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Aip Conference Proceedings
Investigation hydraulic performance of splash fills packing in cooling tower
...Show More Authors

Heat is one of the most energy forms emitted to atmosphere by industrial processes. Water is considered to be the best material to reduce heat energy since its available in nature in abundance and has the ability to absorb heat efficiently. Cooling towers are ideal alternatives to re-cool hot water instead of throwing it especially in places that lack natural water resources or when there are environmental precautions because water with high temperature would be harmful to the ecosystem when it recycled to natural resources such as rivers and lakes. Also, cooling towers considered economically feasible when using west water. This paper interests with hydraulic characteristics of a counter flow wet cooling tower which was investigated experi

... Show More
View Publication
Scopus (6)
Crossref (3)
Scopus Crossref
Publication Date
Mon Mar 23 2020
Journal Name
Journal Of Engineering
Experimental Investigation of Thermal Performance of a Solar Chimney Provided with a Porous Absorber Plate
...Show More Authors

 

Experimental investigation of the influence of inserting the metal foam to the solar chimney to induce natural ventilation are described and analyzed in this work. To carry out the experimental test, two identical solar chimneys (without insertion of metal foam and with insertion of metal foam) are designed and placed facing south with dimensions of length× width× air gap (2 m× 1 m× 0.2 m). Four incline angles are tested (20o,30o,45o,60o) for each chimney in Baghdad climate condition (33.3o latitude, 44.4o longitude) on October, November, December 2018. The solar chimney performance is investigated by experimentally recording absorber pl

... Show More
View Publication Preview PDF
Crossref (4)
Crossref