Hygienic engineering has dedicated a lot of time and energy to studying water filtration because of how important it is to human health. Thorough familiarity with the filtration process is essential for the design engineer to keep up with and profit from advances in filtering technology and equipment as the properties of raw water continue to change. Because it removes sediment, chemicals, odors, and microbes, filtration is an integral part of the water purification process. The most popular technique for treating surface water for municipal water supply is considered fast sand filtration, which can be achieved using either gravity or pressure sand filters. Predicting the performance of units in water treatment plants is a basic principle. For that reason, this research was executed to compare gravity and pressure sand filters in terms of construction, use, efficiency, filtration rate, cost, benefit, and drawbacks to predict the performance of those units under different conditions and from an economic standpoint. It also served as a presentation and review of previous studies dealing with the evaluation and development of pressure and gravity filters. This paper gives a brief overview of filtration theory, the types and properties of filter media, filter backwashing, and operational problems that can be avoided in the filtration process.
KE Sharquie, AA Noaimi, SJ Murtada…, Journal of Cosmetics, Dermatological Sciences and Applications, 2016 - Cited by 4
A Mini-TEA CO2 laser system was designed and operated to obtain a pulse at 10.6 μm. Output energy of 30 mJ, with preionization pins, and pulse duration of 100ns were obtained. While an output energy of 6mJ and pulse duration of 100 ns in absence of pre-ionization were obtained. The system was operated with Ernest profile main-discharge electrodes. Dependencies of supply voltage and output laser energy on the pressure inside laser cavity were investigated as well as dependencies of supply voltage and output energy on the main capacitor(8CO2 : 8N2 : 82He :2CO). Efficiency of was calculated to be 4.4%.
A particle swarm optimization algorithm and neural network like self-tuning PID controller for CSTR system is presented. The scheme of the discrete-time PID control structure is based on neural network and tuned the parameters of the PID controller by using a particle swarm optimization PSO technique as a simple and fast training algorithm. The proposed method has advantage that it is not necessary to use a combined structure of identification and decision because it used PSO. Simulation results show the effectiveness of the proposed adaptive PID neural control algorithm in terms of minimum tracking error and smoothness control signal obtained for non-linear dynamical CSTR system.
This paper describes a new proposed structure of the Proportional Integral Derivative (PID) controller based on modified Elman neural network for the DC-DC buck converter system which is used in battery operation of the portable devices. The Dolphin Echolocation Optimization (DEO) algorithm is considered as a perfect on-line tuning technique therefore, it was used for tuning and obtaining the parameters of the modified Elman neural-PID controller to avoid the local minimum problem during learning the proposed controller. Simulation results show that the best weight parameters of the proposed controller, which are taken from the DEO, lead to find the best action and unsaturated state that will stabilize the Buck converter system performan
... Show MoreThis numerical study explores dynamic melting as an enhancement strategy to improve heat transfer in thermal energy storage (TES) systems utilizing phase change materials (PCM) with openings. Optimizing such systems is crucial for advancing renewable energy storage and integration. A 3D model simulates RT35 PCM flowing through a shell-and-tube heat exchanger annulus. The effects of varying PCM inlet slot diameter (2.5–7.5 mm), inlet pressure (1–40 Pa), and inlet/outlet port positioning on melting fraction and temperature distributions are computationally evaluated. Results show that increasing slot diameter from 2.5 mm to 7.5 mm reduces melting time by 13.6 % (from 550 to 475 min). Raising inlet pressure from 10 Pa to 40 Pa cuts melting
... Show MoreThe main purpose of the research is to study the significance of the event in the explicit source and its significance in the Mimi source and to explain the difference between them in the Holy Quran, especially since most linguists were not interested in what the Mime source indicates in the text, but focused on its form and form, as they defined it as the name Linguists and grammarians did not mention a difference in meaning between the explicit source and the Mimi source, and they interpret the second in the first sense, which led me to choose this topic, to know the significance of each source through Appeal to the maqam and occasion in a challenge D The exact meaning.
In this study, a packed bed was used to remove pathogenic bacteria from synthetic contaminated water. Two types of packing material substrates, sand and zeolite, were used. These substrates were coated with silver nanoparticles (AgNPs), which were prepared by decomposition of Ag ions from AgNO3 solution. The prepared coated packings were characterized using scanning electron microscopy, energy-dispersive X-ray spectroscopy and transmission electron microscopy. The packed column consisted of a PVC cylinder of 2 cm diameter and 20 cm in length. The column was packed with silver nanoparticlecoated substrates (sand or zeolite) at a depth of 10 cm. Four types of bacteria were studied: Escherichia coli, Shigella dysenteriae, Pseudomonas aerugi
... Show MoreExcessive intake of fluoride, mainly through drinking water is a serious health hazard affecting humans worldwide. In this study, the defluoridation capacities of locally available raw waste beef bones have been estimated. Several experimental parameters including contact time, pH, bone dose, fluoride initial concentration, bone grains size, agitation rate, and the effect of co-existence of anions in actual samples of wastewater were studied for fluoride removal from aqueous solutions. Results indicated excellent fluoride removal effeciency up to 99.7% at fluoride initial concentration of 10 mg F/L and 120 min contact time. Maximum fluoride uptake was obtained at neutral pH range 6-7. Fluoride removal kinetic was well described by the ps
... Show More