Preferred Language
Articles
/
joe-1704
Independent Thermal Network Through Thermal Synergy Between Four Architectural Units
...Show More Authors

The manifestations of climate change are increasing with the days: sudden rains and floods, lakes that evaporate, rivers that experience unprecedentedly low water levels, and successive droughts such as the Tigris, Euphrates, Rhine, and Lape rivers. At the same time, energy consumption is increasing, and there is no way to stop the warming of the Earth's atmosphere despite the many conferences and growing interest in environmental problems. An aspect that has not received sufficient attention is the tremendous heat produced by human activities. This work links four elements in the built environment that are known for their high energy consumption (houses, supermarkets, greenhouses, and asphalt roads) according to what is known as the energy synergy to share them within a thermal network independent of the national network. This research concluded that an asphalt road with a length of 6 km is sufficient to heat more than 800 homes, in addition to valuable benefits accrued by hot countries, such as maintaining the quality of the asphalt layer, prolonging its life, and reducing traffic accidents. The supermarket, which needs cooling every day of the year, can meet its energy needs for cooling in the winter by heating the Greenhouse, while the heat flux is stored for each of the greenhouses and the supermarkets for the rest of the year in the thermal tank (TESS).

لتدفق الحراري لكل من الدفيئة والسوبر ماركت لبقية العام في الحرارية. خزان (TESS).

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Aug 01 2020
Journal Name
Proceedings Of International Structural Engineering And Construction
ARCHITECTURAL POTENTIALITY OF FREE-FORM STRUCTURES
...Show More Authors

Contemporary architecture has witnessed a new innovative trend in design characterized by the creation of interesting free-flowing structures that reflect expressiveness of form and design, as well as the uniqueness of structure and approaches of construction. These fascinating structures are often perceived as landmarks that blend harmoniously into their surroundings. In the last two decades, parametric design and advanced computational tools, with prefabrication and construction techniques, enabled architects and engineers to explore new materials and methods to create such impressive structures, breaking the obsolete ways of thinking. Several examples of free-form structures lack obviously to explore architectural potentialities,

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Thu Apr 01 2021
Journal Name
Journal Of Engineering
Innovation Diffusion Elaboration into Architectural Movement
...Show More Authors

The research investigates the term innovation and its role in elaborating architectural practice based on diffusion. The complexity of the architectural field compared with other fields shows a problem in explaining how innovations in architecture diffuse as a thought and act in a certain context of practice. Therefore, the research aims to build an intellectual model that explains the way personal thoughts resembled by unique models introduced by creative and innovator designers diffuse in a certain pattern elaborate these models into a state of prevailing thought resembled by the movement in architecture. The research will apply its model to the more comprehensive movement in architecture, which is the modern movement,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Aug 30 2018
Journal Name
Journal Of Engineering
Mass Transfer Study for Bio-Synergy in Dairy Wastewater Treatment Plant
...Show More Authors

The present study addresses the behavior of gases in cultivation media as an essential factor to develop the relationship between the microorganisms that are present in the same environment. This relationship was explained via mass transfer of those gases to be a reasonable driving force in changing biological trends. Stripping and dissolution of oxygen and carbon dioxide in water and dairy wastewater were investigated in this study. Bubble column bioreactor under thermal control system was constructed and used for these processes. The experimental results showed that the removal of gases from the culture media requires more time than the dissolution. For example, the volumetric mass transfer coefficient for the removal

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Jan 25 2025
Journal Name
Indonesian Journal Of Chemistry
Synthesis of CuO Nanoparticles from Copper(II) Schiff Base Complex: Evaluation via Thermal Decomposition
...Show More Authors

Copper oxide (CuO) nanoparticles were synthesized through the thermal decomposition of a copper(II) Schiff-base complex. The complex was formed by reacting cupric acetate with a Schiff base in a 2:1 metal-to-ligand ratio. The Schiff base itself was synthesized via the condensation of benzidine and 2-hydroxybenzaldehyde in the presence of glacial acetic acid. This newly synthesized symmetric Schiff base served as the ligand for the Cu(II) metal ion complex. The ligand and its complex were characterized using several spectroscopic methods, including FTIR, UV-vis, 1H-NMR, 13C-NMR, CHNS, and AAS, along with TGA, molar conductivity and magnetic susceptibility measurements. The CuO nanoparticles were produced by thermally decomposing the

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
An Investigation into Thermal Performance of Mist Water System and The Related Consumption Energy
...Show More Authors

Experimental tests were conducted to investigate the thermal performance (cooling effect) of water mist system consisting of 5μm volume median diameter droplets in reducing the heat gain entering a room through the roof and the west wall by reducing the outside surface temperature due to the evaporative cooling effect during the hot dry summer of Baghdad/Iraq. The test period
was Fifty one days during the months May, June, and July 2012. The single test day consists of 16 test hours starting from 8:00 am to 12:00 pm. The results showed a reduction range of 1.71 to 15.5℃ of the roof outside surface temperature and 21.3 to 76.6% reduction in the daily heat flux entering the room through the roof compared with the case of not using w

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Journal Of The College Of Education For Women
Speech Acts Through Ages - A Comprative Study between Traditional and Modren Approches
...Show More Authors

This study has been developed axes of the search, including: Search (deliberative) language and idiomatically, and Description Language (b social phenomenon), and the definition of the theory of (acts of speech), and discussed the problem of the conflict between tradition and innovation, as defined objectively have a target aimed at reviving the deliberative thought when Arab scholars , and the balance between the actual done Arab and Western rhetoric, but Meet in intellectual necessity, a sober reading that preserve the Arab language prestige, and its position in the light of the growing tongue Sciences, as long as we have inherited minds unique, and heritage huge able to consolidate the Arab theory lingual in linguistics.

View Publication Preview PDF
Publication Date
Thu Oct 29 2020
Journal Name
The 11th International Renewable Energy Congress (irec 2020)
Thermal efficiency Optimization of the evacuated tube solar water heater system by using mirror flat reflector
...Show More Authors

In this paper a comparison of the experimental of evacuated tube solar water heater systems with and without mirror flat reflector. The aim of using the reflector to improve thermal efficiency, and the data gathered which are (temperature, solar irradiation and time) for three days were compared. the results from compared data the temperature lower increase in evacuated tube solar water heater system without reflector than the temperature increase in evacuated tube solar water heater system with reflector .The results show (53, 39, 35) % for three days respectively that the evacuated tube solar water heater system with reflector has higher thermal efficiencies than the results (47, 28, 30) % for three days respectively thermal efficiencies

... Show More
View Publication
Crossref (4)
Crossref
Publication Date
Sat Aug 31 2024
Journal Name
International Review On Modelling And Simulations (iremos)
Thermal Buckling Analysis of Composite Laminated Shells Using Higher Order Shear Deformation Theory
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Mon Sep 01 2025
Journal Name
Al-khwarizmi Engineering Journal
Impact of Design Parameters in Thermal Solar Water Storage Tank Systems: (A Review)
...Show More Authors

This work provides a historical overview of water storage tanks used for solar energy collection, with a focus on the impact of different geometric configurations on thermal performance and energy storage efficiency. The designs of cylindrical, spherical, rectangular and triangular tanks were reviewed to analyse their effects on thermal gradients, heat retention and energy storage capacity. Within the scope of nominal processes, the study primarily aimed to identify the factors influencing the choice of tank shape in terms of size, capacity and aspect ratio. Another key objective was to assess what enhances heat storage in the tank to improve thermal efficiency. Comparing cylindrical shapes to other shapes, such as spherical, rectan

... Show More
View Publication
Scopus Crossref
Publication Date
Tue Sep 01 2015
Journal Name
2015 Ieee International Circuits And Systems Symposium (icsys)
Investigating the impact of on-chip interconnection noise on Dynamic Thermal Management efficiency
...Show More Authors

Dynamic Thermal Management (DTM) emerged as a solution to address the reliability challenges with thermal hotspots and unbalanced temperatures. DTM efficiency is highly affected by the accuracy of the temperature information presented to the DTM manager. This work aims to investigate the effect of inaccuracy caused by the deep sub-micron (DSM) noise during the transmission of temperature information to the manager on DTM efficiency. A simulation framework has been developed and results show up to 38% DTM performance degradation and 18% unattended cycles in emergency temperature under DSM noise. The finding highlights the importance of further research in providing reliable on-chip data transmission in DTM application.

View Publication
Scopus (1)
Scopus Crossref