Due to a party's violation of his obligations or responsibilities indicated in the contract, many engineering projects confront extensive contractual disputes, which in turn need arbitration or other forms of dispute resolution, which negatively impact the project's outcome. Each contract has its terms for dispute resolution. Therefore, this paper aims to study the provisions for dispute resolution according to Iraqi (SBDW) and the JCT (SBC/Q2016) and also to show the extent of the difference between the two contracts in the application of these provisions. The methodology includes a detailed study of the dispute settlement provisions for both contracts with a comparative analysis to identify the differences in the application of these provisions between the two contracts. The research results revealed several differences, the most important of which is that the engineer has a dual role in Iraqi (SBDW). On the one hand, he is appointed by the employer to carry out specific duties under the contract. On the other hand, the engineer also has powers related to the settlement of claims and this first level of conflict avoidance between the two parties, Unlike the SBC/Q2016 contract, which appoints a neutral third party to mediate the problem. In addition, resolving disputes between the two parties, according to the Iraqi (SBDW), needs a long time compared with JCT-SBC/Q2016.
Abstract
The aim of this paper is to investigate and discuss the mechanisms of corrosion of epoxy coatings used for potable water tanks. Two distinct types of Jotun epoxy coatings: Tankguard 412 contained polyamine cured epoxy and Penguard HB contained polyamide cured epoxy, were tested and studied using the electrochemical impedance spectroscopic (EIS) method. The porosity of epoxy coatings was determined using EIS method. The obtained results showed that the two epoxy coatings have excellent behavior when applied and tested in potable water of Basrah city. Polyamine is more resistance to water corrosion compared to polyamide curing epoxy and has high impedance values. Microscopic inspection after te
... Show MoreBilastine (BL) is a novel non-sedating second-generation antihistamine, and its bioavailability is about 60%. Objective: To compare the bioavailability of prepared oral self-nanoemulsions of BL (BL-SNE) with that of pure BL and marketed tablets. Methods: Four groups of Wistar rats were used in this study, each with six rats weighing between 200 and 250 g. They were treated orally using a a gavage tube. The groups were fed either with conventional tablets ("Alerbix®") after being ground and dispersed with deionized water (DIW), treated with BL-SNE or fed with pure BL powder suspension. The fourth group did not receive any medication. The concentration of BL in the rat’s plasma was measured using HPLC. We used Trandolapril as an an interna
... Show MoreKE Sharquie, AA Noaimi, S Adnan, AM Al-Niddawi, WK Aljanabi, American Journal of Dermatology and Venereology, 2020 - Cited by 2
Background: Radiotherapy, is therapy using ionizing radiation in order to deliver an optimal dose of either particulate or electromagnetic radiation to a particular area of the body with minimal damage to normal tissues. The source of radiation may be outside the body of the patient (external beam irradiation) or it may be an isotope that has been implanted or instilled into abnormal tissue or a body cavity. Called also radiotherapy. The aim of work studies the relationship between the depth dose and the high photon xray energies (6MeV and 10MeV). Patients and methods: in our work, we studied the dose distribution in water phantom given at different depths (zero-18) cm deep at1cm intervals treated with different field size (5×5-,10×1
... Show MoreA new simple, sensitive and inexpensive method has been developed for the spectrophotometric determination of cisapride in pharmaceutical formulation. The turbidimetric method is based on the formation of the ion-pair complex between the drug and bromophenol blue (BPB) in presence of potassium chloride at pH= 2.6, with a maximum absorbance at 520 nm. The calibration graph is linear in the concentration range 5-50µg.ml-1 , with good correlation coefficient (r = 0.9989).The limit of detection was found to be 1.14 µg.ml-1 and no interference was observed from common excipients in the pharmaceutical preparation that contain cisapride with good accuracy and precision.